DC inverter air source heat pump 6KW-9KW-12KW-16KW-19KW-product

Inverter Heating Cooling Heat Pump-9-20KW

  • KOLANT DC inverter heat pump is an overall energy solution for your home.
  • Heating Cooling + Domestic Hot Water in one solution.
  • Compatible with Solar thermal, Solar PV
  • Enery Class A++ with R410a
  • Enery Class A+++ with R32 and R290 refrigerant
  • European standard inverter heat pump
  • With Wifi control function

KOLANT DC inverter heat pump is intended to provide an overall energy solution for your home. it heats or cools your home and at the same time produce domestic hot water to meet all your needs though one device.

  • Solar ready: Compatible with solar thermal panels to be the second heat source of the system.
  • Hot water: Domestic hot water is available all year round.
  • Heating: Suitable for floor heating, radiator heating or fan coil heating.
  • Cooling(optional): Cooling function is available when it is necessary and suitable for fan coil  cooling or area cooling.

DC inverter technology

Standard heat pumps are either ON or OFF. No matter how much the current heat demand is, these heat pumps run at full load even if only for a short time. As any motorist knows, frequently stopping and starting is not a particularly efficient way to drive, as it sends consumption levels through the roof.

In contrast, KOLANT DC inverter heat pump employs not only a DC inverter compressor but an intelligent control system, which operates much more evenly and efficiently. With inverter technology, the heat pump matches its output to the prevailing heat demand with a high degree of precision. Instead of a stop-start pattern, a much more even and energy efficient operation results, which closely mirrors the actual heat demand of the building.

Precise Heat Demand Match

The heating capacity of KOLANT DC inverter heat pump can be precisely regulated from 20% to 100% according to the actual heat demand. Accordingly, the water temperature in the system will be steadily controlled with a very small deviation of no more than 0.5℃ so as to create a comfortable living environment.

Wider Operating Range

KOLANT DC inverter heat pump can reliably and efficiently run with a bigger operating range. For example, even when the environment temperature as cold as -20℃ , the heat pump still can provide warm water with high water temperature and high heating output. However, normalheat pumps even can not work in this situation.

Energy efficiency class A+++ (tested by TUV)

KOLANT DC inverter heating technology makes a very high energy efficiency within all the permitted operating range. For example, when the ambient air is not so cold and the heat demand is not so big, the heat pump runs with low heat output but a particularly high efficiency. However, when ambient air is extremely cold, the heat pump runs with full load to reduce or eliminate the aid of the booster heater. The intelligent control system is always trying to maximize the efficiency of the whole heating system. As a matter of fact, all KOLANT DC inverter heat pumps have energy efficiency class A+++.

Your annual energy bill by different heating devices

 DC Inverter Heat pumpNormal ON/OFF Heat pumpGasDieselElectricity
Calorific value860kcal/kWh860kcal/kWh860kcal/kWh10,200kcal/L860kcal/kWh
Energy efficiency425%(A++)300%(A)85%85%95%
Energy price0.167€/kWh0.167€/kWh0.071€/kWh1.61€/L0.167€/kWh
Annual heating demand Qh25,445kWh25,445kWh25,445kWh25,445kWh25,445kWh
Annual energy consumption5,987kWh8,482kWh29,935kWh2,524L26,784kWh
Annual energy bill999.8€1,416.5€2,125.4€4,063.6€4,488.0€

Smart WIFI control

By downloading our APP in your mobile phone, it is possible for you to conveniently control a DC inverter heat pump from KOLANT at any time, anywhere. Just imagine that you turn on your heat pump and set it to a comfortable temperature before you leave office, then you will enjoy the pleasant environment as soon as you get home, It is fantastic, isn’t it?

High quality components, long lifetime

All the key components are from leading suppliers to make sure the quality and lifetime. For example, the DC inverter compressors are from Panasonic, the high efficiency plate heat exchangers are from Swep etc.

Intelligent compressor driver

EVI Inverter Compressors

Plate heat exchanger

Two EEV expansion valves

Alco water flow switch

Technical Data

Models  Air temp/outlet water tempRJP-60H/N8-BPGCOPRJP-90H/N8-BPGCOPRJP-120H/N8-BPGCOPRJP-160H/N8-BPGCOPRJP-190H/N8-BPGCOP
Heating capacity/Power input (KW)at A20/W35°C 8.44/1.415.9912.1/2.025.9916.32/2.775.8921.88/3.665.9825.4/4.55.64
at A7/W35°C 6.21/1.264.938.9/1.814.9212/2.54.816.3/3.344.8818.7/4.064.61
at A7/W45°C 5.91/1.483.998.46/2.123.9911.29/3.083.6715.31/3.883.9517.78/4.753.74
at A2/W35°C 5.56/1.224.567.97/1.764.5310.8/2.444.4314.49/3.234.4916.8/3.974.23
at A2/W45°C 5.32/1.453.677.61/2.073.6810.16/3.013.3813.78/3.83.6316/4.653.44
Cooling Capacity/Power input(KW)at A35/ W18ºC6.35/1.63.978.1/2.083.8911/3.123.5315.6/4.33.6316.6/4.53.69
at A35/W7ºC4.9/1.652.975.9/22.958.1/2.832.8611.4/42.8512/4.22.86
Compressor Mitsubishi Mitsubishi Mitsubishi Mitsubishi Mitsubishi 
Max.currentt                           (A)13 13 19 25 9 
Electric supply230V/50-60Hz230V/1Phase or 400V/3Phase 50~60HZ
Max.water temperature   ( oC)60
Running temperature range  (oC)-25 ~ 43
Refrigerant circuitRefrigerantR32
DC Inverter compressor(s)Twin Rotary
Heat exchangeCopper and Hydrauphilic Aluminum Fin
Air flow     (m3/h)2100 2400 2900 5600 5600 
Water circuitHeat exchangerPlate heat exchanger   
In/Out pipeDN25(1”) DN25(1”) DN32
Water flow  (m3/h)≥0.8 ≥1.2 ≥1.8 ≥2.3 ≥2.3 
permitted pressure≤0.8MPa
Unit dimensions   WxHxD   (mm)1115*710*425 1115*710*425 1115*960*425 1115*1280*425 1115*1280*425 
Pacage dimensions   WxHxD   (mm)1170*870*500 1170*870*500 1170*1250*500 1170*1550*500 1170*1550*500 
Net weight                               (Kg)90 90 105 140 140 
Gross weight                            (Kg)110 110 115 150 150 
Noise level                             (dB(A))46 46 50 52 52 
Loading quantity for 20’/40′44/88 44/88 44/88 22/44 22/44 

1 thought on “DC inverter air source heat pump 6KW-9KW-12KW-16KW-19KW-product”

leave a message to us

Your email address will not be published. Required fields are marked *

Scroll to Top
contact | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988
Get a quotation now!

    Your Name

    Your Email

    Your Message