Full heat recovery system to utilize solar hot water, or ground water source for room heating and domestic hot water.
Cool solar panel for higher efficency and use its heat for room in the same time. One side cooling or heating is free cost.
Water source is priority to save energy, lower noise.
Thanks to our Epoch-Making new technolgy, our new heat recovery heat pump efficency (COP) is up to 7.0 when central cooling + hot water; COP is up to 5.0 when central heating+hot water.
It means 1KW electricity input equal 7KW output.
Kolant Central Heating+Central Cooling+Domestic hot water with heat recovery Heat Pump available for 7KW,10KW,14KW,17KW,20KW,25KW,30KW,40KW,50KW,60KW
Product Function:
Central Heating, central cooling and domestic hot water function in one solution.
Provide free hot water when cooling
4. Environment friendly: R410a refrigerant, no pollution, no waste discharge;
5. Economic: The running cost of Kolant heat pump can be 85% less than that of a traditional gas boiler heating system;
6.Advanced timer setting function for heat pump :
Single day timer and Weekly timer are both available. Can be different setting for every day of the whole week.
Heat recovery heat pump technical data:
Model | RJ-150H/N2BPEVI-50N2 | RJ-220H/N2BPEVI-50N2 | RJ-300H/SN2BPEVI-72N2 | RJ-400H/SN2BPEVI-72N2 | ||||||||
Different condition | Add heat recovery | 40Hz working | Add heat recovery | 40Hz working | Add heat recovery | 40Hz working | Add heat recovery | 40Hz working | ||||
power supply | 1N-220V/50HZ | 3N-380V/50HZ | 3N-380V/50HZ | 3N-380V/50HZ | ||||||||
Rated heating(W) | 18000 | 22000 | 13200 | 24000 | 28000 | 16800 | 33500 | 38000 | 22800 | 44600 | 49100 | 29460 |
Rated heating power(W) | 4180 | 4180 | 1760 | 5130 | 5130 | 2310 | 7800 | 7800 | 3510 | 9630 | 9630 | 4333.5 |
COP | 4.31 | 5.26 | 7.5 | 4.68 | 5.46 | 7.27 | 4.29 | 4.87 | 6.5 | 4.63 | 5.1 | 6.8 |
Rated heating current | 19A | 23.3A | 11.8 A | 14.6 A | ||||||||
Rated cooling | 15000W | 22000W | 31000W | 41000W | ||||||||
Rated cooling power | 5003W | 4760W | 10470W | 8950W | ||||||||
Rated cooling current | 22.7A | 21.6A | 15.9A | 13.6A | ||||||||
Rated hot water | 5000W | 5000W | 7200W | 7200W | ||||||||
Rated hot water power | 1220W | 1220W | 1780W | 1780W | ||||||||
Rated hot water current | 5.54A | 5.54 A | 8.09A | 8.09A | ||||||||
Maximum input power (excluding electric heating) | 7000W | 7000W | 14650W | 14650W | ||||||||
Maximum input current (excluding electric heating) | 31.8 A | 31.8 A | 31.8A | 31.8A | ||||||||
Rated circulation volume of air conditioning water | 2500L/h | 3500 L/h | 5500 L/h | 7000 L/h | ||||||||
Hot water production | 180 L/h | 180 L/h | 240 L/h | 240 L/h | ||||||||
refrigerant | R32 | R32 | R32 | R32 | ||||||||
Compressor type | Two compressors-one Inverter + one on/off type(DHW) | |||||||||||
water side heat exchanger | Plate exchange + high efficiency tube in shell heat exchanger | |||||||||||
Hot water inlet interface | DN20 (3/4 “) | |||||||||||
Hot water outlet interface | DN20 (3/4 “) | |||||||||||
Air conditioner water inlet | DN40 (1-1/4 “) | |||||||||||
Air conditioner water outlet | DN40 (1-1/4 “) | |||||||||||
Subcooled water inlet interface | / | DN20 (3/4 “) | / | DN25 (1″) | ||||||||
Supercooling water outlet | / | DN20 (3/4 “) | / | DN25 (1″) | ||||||||
Maximum pressure on water side | 0.6MPa | |||||||||||
Minimum pressure on water side | 0.1 M p a (must be pressure-bearing) | |||||||||||
Operating noise (dB(A)) | 56 | 56 | 58 | 58 | ||||||||
Cold water inlet pressure | >=0.1 MPa |
Reliable Quality for saving maintenance cost:
Our parts are always choosend with the top brand in the world
Heat exchanger: SU316 stainless plate heat exchanger.
The compressor: Daikin, Hitachi,Toshiba,Sanyo brand
Optional water pump: Wilo brand from Germany
Four way valve: Saginomiya brand of Japan
The above parts enable our heat pump to be trouble free products.
We provide 1% free spareparts and 1 year warranty for factory fault since shipment arrival.
We will send the spare parts by courrier method after confirm it is due to factory fault.
We don’t cover the cost for failure from shipment, wrong installation and incorrect usage. Of course we can provide parts by customer’s cost after warranty period.
We can provide free heat pump installation consultation.
We can help to purchase other parts related to heat pumps or recommand reliable suppliers directly.
For heat pump samples delivery, after packing with export class thick 5 layers paper box, we will pack heat pumps with poly wood case to avoid any damage as shown attached.
There are two ways to delivery the samples.
For sea freight, we will keep the refrigerant inside of the heat pump.
For air freight cargo, due to the air line regulation, we need to drain out the refrigerant. So you need to charge the refrigerant if you find the heat pump cannot start.
For all products above 50kg, we will fix it on a good structured wood or polywood pallet as shown below.
For Container delivery, we use only export thick 5 layer paper box. After carefully loading, we will take pictures before close the container door to assure everything is ok.
If by sea, normally we export at EXW, FOB or CFR terms, we only delivery goods to the destination sea port. The customers need to cover cost for their import duty and cost. Of course the customers can use our forwarder agent to help you to clear the customs.
We can provide all necessary document such as Form A, certificate of origin, Bill of lading, Invoice and packing list.
Normally it will take about 30 days by sea and one week by air.