Two independent compressor and refrigeration system. Real Heating cooling and DHW system.
Recover heat for domestic hot water heating in both heating and cooling function.
Add in cooling tower and geo source to increase COP and EER dramatically to save cost the most
Full heat recovery system to utilize solar hot water, or ground water source for room heating and domestic hot water.
Cool solar panel for higher efficiency and use its heat for room in the same time. One side cooling or heating is free cost.
Water source is priority to save energy, lower noise.
Thanks to our Epoch-Making new technology, our new heat recovery heat pump efficiency (COP) is up to 7.0 when central cooling + hot water; El COP es de hasta 5,0 con calefacción central+agua caliente.
Esto significa que 1 kW de entrada de electricidad equivale a 7 kW de salida.
Kolant Central Heating+Central Cooling+Domestic hot water with heat recovery Heat Pump available for 15KW,22KW,30KW,40KW.
Función del producto:
Calefacción central, refrigeración central y agua caliente sanitaria en una sola solución.
Provide free hot water at both heating and cooling function.
4. Environment friendly: R410a,R32 refrigerant, no pollution, no waste discharge;
5. Economic: The running cost of Kolant heat pump can be 85% less than that of a traditional gas boiler heating system;
6.Advanced timer setting function for bomba de calor :
Single day timer and Weekly timer are both available. Can be different setting for every day of the whole week.
Datos técnicos de la bomba de calor con recuperación de calor:
| Modelo | RJ-150H/N2BPEVI-50N2 | RJ-220H/N2BPEVI-50N2 | RJ-300H/SN2BPEVI-72N2 | RJ-400H/SN2BPEVI-72N2 | ||||||||
| Different condition | Add heat recovery | 40Hz working | Add heat recovery | 40Hz working | Add heat recovery | 40Hz working | Add heat recovery | 40Hz working | ||||
| power supply | 1N-220V/50HZ | 3N-380V/50HZ | 3N-380V/50HZ | 3N-380V/50HZ | ||||||||
| Rated heating(W) | 18000 | 22000 | 13200 | 24000 | 28000 | 16800 | 33500 | 38000 | 22800 | 44600 | 49100 | 29460 |
| Rated heating power(W) | 4180 | 4180 | 1760 | 5130 | 5130 | 2310 | 7800 | 7800 | 3510 | 9630 | 9630 | 4333.5 |
| COP | 4.31 | 5.26 | 7.5 | 4.68 | 5.46 | 7.27 | 4.29 | 4.87 | 6.5 | 4.63 | 5.1 | 6.8 |
| Rated heating current | 19A | 23.3A | 11.8 A | 14.6 A | ||||||||
| Rated cooling | 15000W | 22000W | 31000W | 41000W | ||||||||
| Rated cooling power | 5003W | 4760W | 10470W | 8950W | ||||||||
| Rated cooling current | 22.7A | 21.6A | 15.9A | 13.6A | ||||||||
| Rated hot water | 5000W | 5000W | 7200W | 7200W | ||||||||
| Rated hot water power | 1220W | 1220W | 1780W | 1780W | ||||||||
| Rated hot water current | 5.54A | 5.54 A | 8.09A | 8.09A | ||||||||
| Maximum input power (excluding electric heating) | 7000W | 7000W | 14650W | 14650W | ||||||||
| Maximum input current (excluding electric heating) | 31.8 A | 31.8 A | 31.8A | 31.8A | ||||||||
| Rated circulation volume of air conditioning water | 2500L/h | 3500 L/h | 5500 L/h | 7000 L/h | ||||||||
| Hot water production | 180 L/h | 180 L/h | 240 L/h | 240 L/h | ||||||||
| refrigerant | R32 | R32 | R32 | R32 | ||||||||
| Tipo de compresor | Two compressors-one Inverter + one on/off type(DHW) | |||||||||||
| water side heat exchanger | Plate exchange + high efficiency tube in shell heat exchanger | |||||||||||
| Hot water inlet interface | DN20 (3/4 “) | |||||||||||
| Hot water outlet interface | DN20 (3/4 “) | |||||||||||
| Air conditioner water inlet | DN40 (1-1/4 “) | |||||||||||
| Air conditioner water outlet | DN40 (1-1/4 “) | |||||||||||
| Subcooled water inlet interface | / | DN20 (3/4 “) | / | DN25 (1″) | ||||||||
| Supercooling water outlet | / | DN20 (3/4 “) | / | DN25 (1″) | ||||||||
| Maximum pressure on water side | 0.6MPa | |||||||||||
| Minimum pressure on water side | 0.1 M p a (must be pressure-bearing) | |||||||||||
| Operating noise (dB(A)) | 56 | 56 | 58 | 58 | ||||||||
| Cold water inlet pressure | >=0.1 MPa | |||||||||||
Calidad fiable para ahorrar en costes de mantenimiento:
Nuestros recambios siempre se seleccionan entre las mejores marcas del mundo.
Intercambiador de calor: intercambiador de calor de placas de acero inoxidable SU316.
The compressor: Daikin, Hitachi,Toshiba,Sanyo brand
Estas piezas permiten que nuestra bomba de calor sea un producto sin problemas.
Garantía
We provide 1% free spare parts and 2 year warranty for factory fault since shipment arrival.
We will send the spare parts by courier method after confirm it is due to factory fault.
No cubrimos los gastos derivados de averías causadas por el transporte, una instalación incorrecta o un uso inadecuado. Por supuesto, podemos suministrar piezas a cargo del cliente una vez finalizado el periodo de garantía.
Atención al cliente
Le asesoramos gratuitamente sobre la instalación de una bomba de calor.
We can help to purchase other parts related to heat pumps or recommend reliable suppliers directly.
Envío
Para el envío de muestras de bombas de calor, tras embalarlas en una caja de cartón de 5 capas de gran grosor, apta para la exportación, las colocaremos en una caja de madera y polietileno para evitar cualquier daño, tal y como se muestra en el archivo adjunto.
Hay dos formas de enviar las muestras.
En el caso del transporte marítimo, mantendremos el refrigerante dentro de la bomba de calor.
En el caso del transporte aéreo de mercancías, debido a la normativa de las compañías aéreas, debemos purgar el refrigerante. Por lo tanto, deberá recargar el refrigerante si observa que la bomba de calor no arranca.
Para todos los productos que pesen más de 50 kg, los fijaremos en un palé de madera o de polimero bien estructurado, tal y como se muestra a continuación.
Para el envío en contenedor, utilizamos exclusivamente cajas de cartón de 5 capas, resistentes para la exportación. Tras cargar la mercancía con cuidado, tomaremos fotografías antes de cerrar la puerta del contenedor para asegurarnos de que todo está en orden.

Si el envío se realiza por mar, normalmente exportamos en condiciones EXW, FOB o CFR, y solo entregamos la mercancía en el puerto marítimo de destino. Los clientes deben hacerse cargo de los aranceles de importación y los gastos correspondientes. Por supuesto, los clientes pueden recurrir a nuestro agente de transporte para que les ayude con los trámites aduaneros.
Podemos facilitar toda la documentación necesaria, como el formulario A, el certificado de origen, el conocimiento de embarque, la factura y la lista de embalaje.
Normalmente, el envío tarda unos 30 días por mar y una semana por vía aérea.