There is no doubt that air source heat pumps can make great economic and environmental benefits if they are properly used. However, as a matter of fact, most air source heat pumps work with very poor efficiency or even can not work when the environment temperature is lower than -10℃.
The EVI (enhanced vapor injection) heating technology indeed represents a significant innovation in the compressor and refrigerant circulation systems.
Kolant provides various capacities of EVI heat pumps for both residential or commercial applications. The heat pump can be used not only for heating in cold areas, but also for hot water or cooling as the optional function. They can be widely used for different purposes in different occasions.
The heating capacity of KOLANT EVI DC inverter heat pump can be precisely regulated from 20% to 100% according to the actual heat demand. Accordingly, the water temperature in the system will be steadily controlled with a very small deviation of no more than 0.5℃ so as to create a comfortable living environment.
KOLANT DC inverter heat pump can work under environment temperature -35℃
Getting much higher water temperature during low environment temperature
Heating capacity up to 40% higher than normal heat pumps
COP 10%-20% higher during low environment temperature
Kolant EVI heat pump has achieved an outstanding feat by attaining the prestigious energy class A+++ rating, as rigorously tested by TUV in accordance with the EN14825 and EU813 standards. This remarkable accomplishment underscores the pump’s unrivaled energy efficiency.
The EN14825 standard assesses heat pumps comprehensively, taking into account factors such as heating capacity, seasonal performance, and energy consumption under different operating conditions. By meeting this standard, Kolant EVI heat pump demonstrates its ability to provide consistent and reliable heating while consuming minimal energy.
The EU813 standard further validates the pump’s environmental friendliness and energy – saving capabilities. An A+++ energy class indicates that the Kolant EVI heat pump is among the top – tier, most energy – efficient models in the market. For consumers, this means significant savings on energy bills over time. Whether used in residential homes for cozy heating during winters or in commercial buildings to maintain a comfortable indoor climate, the Kolant EVI heat pump not only cuts down on electricity costs but also reduces the carbon footprint. It sets a high benchmark for the industry, proving that advanced technology can be harnessed to create products that are both powerful in performance and kind to the environment.
Kolant manufacture EVI heat pump capacity range 6KW~40kw of EVI heat pumps for both residential or commercial applications. The heat pump can provide Heating/cooling and domestic hot water in one solution.
Kolant heat pump built modbus protocol inside. Through the MODBUS protocol, operators gain comprehensive control. They can precisely regulate each heat pump’s temperature, ensuring a consistent indoor climate. Fan speeds can also be adjusted according to specific requirements, optimizing air circulation. By centralizing control over these 99 units, energy management becomes highly efficient. For instance, during periods of low demand, the system can be configured to run at reduced power, conserving energy while maintaining comfort levels. The maximum heating capacity of one system can be about 4,000kW via modbus control.
By downloading our APP in your mobile phone, it is possible for you to conveniently control a DC inverter heat pump from KOLANT at any time, anywhere. Just imagine that you turn on your heat pump and set it to a comfortable temperature before you leave office, then you will enjoy the pleasant environment as soon as you get home, It is fantastic, isn’t it?
The smart touch screen controller is friendly to all users, users can easily operate it without big effort. It is also very convenient for service people to check all the sensor data and the running state, set parameters with the aid of the controller.
All the key components are from leading suppliers to make sure the quality and lifetime. For example, the DC inverter compressors are from Panasonic, the high efficiency plate heat exchangers are from Swep etc
| Models | Air temp/outlet water temp | RJ60H/N8-BPEEVI | COP | RJ85H/N8-BPEEVI | COP | RJ-110H/N8-BPE | COP | RJ-150H/SN8-BPEEVI | COP | RJ-180H/SN8-BPEEVI | COP | RJ-230H/SN8-BPEEVI | COP | RJ-300H/SN8- BPEEVI | COP | RJ-450H/SN8- BPEEVI | COP |
| Heating capacity/Power input (KW/KW) | at A20/W35°C | 9.11/1.62 | 5.62 | 10.6/1.89 | 5.61 | 14.42/2.88 | 5.01 | 21.1/3.89 | 5.42 | 22.8/4.4 | 5.18 | 29.5/6.01 | 4.91 | 40.92/8.49 | 4.82 | 58.27/13.27 | 4.39 |
| at A7/W35°C | 6.7/1.45 | 4.62 | 8.59/1.87 | 4.59 | 10.6/2.55 | 4.16 | 14.7/3.31 | 4.44 | 18.8/4.4 | 4.27 | 23.1/5.34 | 4.33 | 31.6/7.8 | 4.05 | 45/12.2 | 3.69 | |
| at A7/W45°C | 6.2/1.55 | 4.00 | 7.91/2.23 | 3.55 | 9.97/3.14 | 3.18 | 13.5/4.1 | 3.29 | 17.8/5.24 | 3.4 | 22.6/6.11 | 3.7 | 29.12/9.27 | 3.14 | 41.47/14.5 | 2.86 | |
| at A2/W35°C | 6.16/1.45 | 4.25 | 7.65/1.81 | 4.23 | 9.54/2.49 | 3.83 | 13.08/3.21 | 4.07 | 16.92/4.31 | 3.93 | 20.29/5.38 | 3.77 | 29.07/7.79 | 3.73 | 41.4/12.21 | 3.39 | |
| at A2/W45°C | 5.58/1.52 | 3.67 | 7.04/2.15 | 3.27 | 8.97/3.06 | 2.93 | 12.02/3.97 | 3.03 | 16/5.12 | 3.13 | 18.7/6.4 | 2.92 | 26.5/9.17 | 2.89 | 37.74/14.35 | 2.63 | |
| at A-12/W41°C | 4.2/1.68 | 2.5 | 5.9/2.45 | 2.41 | 6.3/2.7 | 2.33 | 10.2/4.35 | 2.34 | 11.6/5.04 | 2.3 | 14.7/5.88 | 2.5 | 20.2/8.38 | 2.41 | 29.5/12.9 | 2.29 | |
| at A-20/W41°C | 3.85/2.1 | 1.83 | 5.4/2.56 | 2.11 | 5.61/2.72 | 2.06 | 8.9/4.23 | 2.1 | 10.5/4.97 | 2.11 | 13.7/5.78 | 2.37 | 18.5/8.73 | 2.12 | 26/13.7 | 1.9 | |
| Cooling Capacity/Power input(KW/KW) | at A35/ W18ºC | 6.6/1.9 | 3.47 | 9.2/2.7 | 3.41 | 11/3.3 | 3.33 | 13.9/4.2 | 3.31 | 15.6/4.8 | 3.25 | 20.1/6.2 | 3.24 | 26/8.5 | 3.06 | 37.8/12.5 | 3.02 |
| at A35/W7ºC | 5.2/1.92 | 2.71 | 7.2/2.73 | 2.64 | 8.6/3.4 | 2.53 | 9.8/3.77 | 2.6 | 10.5/4.2 | 2.5 | 13.5/5.09 | 2.65 | 17.5/7.06 | 2.48 | 24/9.8 | 2.45 | |
| Max.current (A) | 13.2 | 18 | 19 | 28 | 14.3 | 18.1 | 16.7 | 24.2 | |||||||||
| Electric supply | 230V/50~60HZ | 230V/50~60HZ | 400V/50~60HZ | 400V/50~60HZ | |||||||||||||
| Max.Outlet water temperature ( oC) | 60 | ||||||||||||||||
| Running temperature range (oC) | -35 ~ 43 | ||||||||||||||||
| Refrigerant circuit | Refrigerant | R32 | |||||||||||||||
| DC Inverter compressor(s) | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | |||||||||
| Heat exchange | Copper and Hydrauphilic Aluminum Fin | ||||||||||||||||
| Air flow (m3/h) | 2100 | 2400 | 2900 | 5800 | 6000 | 7000 | 9000 | 12000 | |||||||||
| Water circuit | Heat exchanger | High efficiency tube in shell heat exchanger | |||||||||||||||
| In/Out pipe | DN20 | DN25(G1″) | DN25(G1″) | DN25(G1″) | DN25(G1″) | DN25(G1″) | DN32 | DN32 | |||||||||
| Water flow (m3/h) | >1 | ≥1.5 | ≥1.8 | ≥2.5 | ≥3 | ≥3.9 | >5 | >7 | |||||||||
| permitted pressure | ≤0.8MPa | ||||||||||||||||
| Unit dimensions WxHxD (mm) | 855*605*295 | 960*820*380 | 960*820*380 | 960*1270*380 | 960*1270*380 | 1030*1340*390 | 1066*1427*392 | 1185*1660*400 | |||||||||
| Pacage dimensions WxHxD (mm) | 935*725*420 | 1040*940*502 | 1040*940*502 | 1040*1390*502 | 1040*1390*502 | 1115*1510*510 | 1151*1597*512 | 1270*1830*520 | |||||||||
| Net weight (Kg) | 54 | 68 | 68 | 108 | 108 | 128 | 145 | 200 | |||||||||
| Gross weight (Kg) | 63 | 85 | 85 | 125 | 125 | 145 | 162 | 220 | |||||||||
| Noise level (dB(A)) | 54 | 56 | 56 | 59 | 59 | 60 | 62 | 65 | |||||||||
| Loading quantity for 20’/40′ (PCS) | 100/200 | 44/88 | 44/88 | 22/44 | 22/44 | 22/44 | 20/40 | 20/40 | |||||||||
Much more advantage for rain, snow proof.
Heating cooling and domestic hot water functions in one solution.
1. Optional Solar PV DC voltage connection, which enable more energy saving than other heat pump.
2. Intelligent automatic operation mode of DHW and room heating for more energy saving during different ambient temp;
3. Real weekly timer-Different setting for every day of the week to fit your life habit the most and save energy. Imaging you will enjoy your weekend in tourism with your sweet family, then the heat pump doesn’t need to start at weekend.
4.All error code can be checked through controller display and mobile APP which enable you to solve the problem as soon as possible.