Domestic Hot Water & Shower Water Heat Pump
- KOLANT domestic hot water heat pump provide High efficiency and energy saving.
- All year round operation, continuous hot water and shower water.
- High flexibility, suitable for most hot water systems.
- Maximum water temperature up to 75℃ (hightemperature series).
- All important parts from world famous brands, reliable and durable.
- CB/CE standard conformity, designed according to international standards.
We got the Certificates: TUV ISO9001, ISO45001(Health&Safety), ISO14001 (Environment), TUV EN14825( A+++), TUV CE , TUV CB
Your best choice for commercial hot water heat pump
Energy consumption of hot water accounts for a considerable percentage in commercial buildings. According to some investigation, this percentage can even be as high as 40% in some hotels, nursing homes, hospitals etc. Heat pumps, however, generate hot water mostly with renewable energy are especially suitable for commercial hot water project. Using KOLANT heat pumps as the heating devices or replacing those existed boilers in commercial buildings makes great benefits in
economic and environmental prospects. With large capacity range from 10kW to
250kW, KOLANT commercial heat pumps provides various choices for users to get the most cost-effective solution for hot water projects.
The main heat pump and the hot water tank are independent. The water pipes are connected freely and simply, the heat pump can be hung on the wall or placed on the balcony/roof, and can be installed on 99% floors.
Multi-protection function built inside
- Multi-protection function built inside Kolant hot water heat pump such as leakage protection, high/low voltage protection, high temperature protection, current overload protection start delay, water flow protection, heat exchanger anti-freezing protection and so on, to fully protect the normal operation and service life of the hot water heat pump.Water-water heat exchange has no hidden dangers such as electric leakage, fluorine leakage and corrosion, dry burning of electric water heaters, and no toxic and harmful gases such as CO, so water use is safer.
Plage de fonctionnement élargie
KOLANT hot heat pump can reliably and efficiently run with a bigger operating range. EVI model can working with good efficiency at -30℃ ambient temperature. Normal heat pumps even can not work lower than -15 ℃ ambient temperature.
Your annual energy bill by different heating devices
| Pompe à chaleur à onduleur CC | Pompe à chaleur avec mode marche/arrêt standard | Gaz | Diesel | L'électricité | |
| Valeur calorifique | 860 kcal/kWh | 860 kcal/kWh | 860 kcal/kWh | 10 200 kcal/L | 860 kcal/kWh |
| Efficacité énergétique | 425%(A++) | 300%(A) | 85% | 85% | 95% |
| Prix de l'énergie | 0,167 €/kWh | 0,167 €/kWh | 0,071 €/kWh | 1,61 €/l | 0,167 €/kWh |
| Besoin annuel en chauffage Qh | 25 445 kWh | 25 445 kWh | 25 445 kWh | 25 445 kWh | 25 445 kWh |
| Consommation énergétique annuelle | 5 987 kWh | 8 482 kWh | 29 935 kWh | 2 524 L | 26 784 kWh |
| Facture énergétique annuelle | 999.8€ | 1,416.5€ | 2,125.4€ | 4,063.6€ | 4,488.0€ |
Pompe à chaleur Kolant PLUS économique que les autres appareils
Contrôle WIFI intelligent
En téléchargeant notre application sur votre téléphone portable, il vous est possible de contrôler confortablement une pompe à chaleur DC inverter de KOLANT à tout moment et en tout lieu. Imaginez que vous allumez votre pompe à chaleur et que vous la réglez à une température confortable avant de quitter le bureau, puis que vous profitez d'un environnement agréable dès que vous rentrez chez vous, c'est fantastique, n'est-ce pas ?
Intelligent LCD controller
The smart touch screen controller is friendly to all users, users can easily operate it without big effort. It is also very convenient for service people to check all the sensor data and the running state, set parameters with the aid of the controller.
Composants de haute qualité, longue durée de vie
Tous les composants clés proviennent de fournisseurs de premier plan afin de garantir la qualité et la durée de vie. Par exemple, les compresseurs à inverseur CC sont de Panasonic, les échangeurs de chaleur à plaques à haut rendement sont de Swep, etc.
Pilote de compresseur intelligent
Tube-in-shell condenser
Commerical heat pump axial fan
Scroll Compressor
Données techniques
![]() | ![]() | ![]() | ![]() | |||
| Modèle | RJ-90H/N2-BP | RJ-120H/N2-BP | RJ-160H/N2-BP | RJ-200H/N2-BPD | ||
| Performance data according to EN14511 | ||||||
| Heating output/power input/COP at A7/W35 | kW/kW/- | 8.7/1.90/4.58 | 12.0/2.70/4.44 | 15.6/3.60/4.33 | 19.5/4.61/4.23 | |
| Heating output/power input/COP at A2/W35 | kW/kW/- | 8.8/2.18/4.04 | 11.5/2.90/3.97 | 15.5/3.99/3.88 | 19.6/5.12/3.83 | |
| Heating output/power input/COP at A-7/W35 | kW/kW/- | 7.1/2.39/2.97 | 9.3/3.08/3.02 | 12.8/4.52/2.83 | 16.3/5.78/2.82 | |
| Heating output/power input/COP at A7/W45 | kW/kW/- | 8.5/2.40/3.54 | 11.4/3.12/3.65 | 14.7/4.28/3.43 | 18.8/5.52/3.41 | |
| Heating output/power input/COP at A-7/W45 | kW/kW/- | 6.8/2.87/2.37 | 9.0/3.74/2.41 | 12.3/5.46/2.25 | 14.7/6.46/2.28 | |
| Heating output/power input/COP at A7/W55 | kW/kW/- | 8.0/2.64/3.03 | 10.8/3.53/3.06 | 14.1/4.66/3.03 | 17.6/5.99/2.94 | |
| Cooling output/power input/EER at A35/W7 | kW/kW/- | 7.1/2.50/2.84 | 9.6/3.30/2.91 | 12.0/4.50/2.67 | 15.1/5.89/2.56 | |
| Energy efficiency class according to EN14825 | ||||||
| Average climate for floor heating | A++ | A++ | A++ | A++ | ||
| Average climate for radiator heating | A++ | A++ | A++ | A++ | ||
| Electrical data | ||||||
| Alimentation électrique | 230V/50Hz | 230V/50Hz | 230V/51Hz | 230V/52Hz | ||
| Maximum power consumption | kW | 3.7 | 4.8 | 6 | 6.8 | |
| Maximum input current | Un | 16.2 | 21 | 26.2 | 29.8 | |
| Application range | ||||||
| Water temperature range | Chauffage | ℃ | 18~60 | 18~61 | 18~62 | 18~63 |
| De refroidissement | ℃ | 8~28 | 8~29 | 8~30 | 8~31 | |
| Ambient air temperature range | Chauffage | ℃ | -20~43 | -20~44 | -20~45 | -20~46 |
| De refroidissement | ℃ | 15~43 | 15~44 | 15~45 | 15~46 | |
| Other technical data | ||||||
| Type of refrigerant | R410A | R411A | R412A | R413A | ||
| Maximum operating pressure | MPa | 4.2 | 5.2 | 6.2 | 7.2 | |
| Type of evaporator | Fine-tube | Fine-tube | Fine-tube | Fine-tube | ||
| Débit d'eau nominal | m3/h | R410A | R411A | R412A | R413A | |
| Internal water pressure loss | KPa | 19 | 20 | 22 | 24 | |
| Diameter of water connection | mm | DN25 | DN25 | DN32 | DN33 | |
| Noise level at 1 meter | dB(A) | 54 | 56 | 57 | 58 | |
| Net dimensions (W*D*H) | mm | 1115*450*926 | 115*450*1076 | 1115*450*1276 | 1115*450*1480 | |
| Packing dimensions (W*D*H) | mm | 1170*490*1055 | 1170*490*1205 | 1170*490*1420 | 1170*490*1620 | |