Domestic Hot Water & Shower Water Heat Pump

Domestic Hot Water & Shower Water Heat Pump

  • KOLANT domestic hot water heat pump provide High efficiency and energy saving.
  • All year round operation, continuous hot water and shower water.
  • High flexibility, suitable for most hot water systems.
  • Maximum water temperature up to 75℃ (hightemperature series).
  • All important parts from world famous brands, reliable and durable.
  • CB/CE standard conformity, designed according to international standards.
We got the Certificates: TUV ISO9001, ISO45001(Health&Safety), ISO14001 (Environment), TUV EN14825( A+++), TUV CE , TUV CB

Your best choice for commercial hot water heat pump

Energy consumption of hot water accounts for a considerable percentage in commercial buildings. According to some investigation, this percentage can even be as high as 40% in some hotels, nursing homes, hospitals etc. Heat pumps, however, generate hot water mostly with renewable energy are especially suitable for commercial hot water project. Using KOLANT heat pumps as the heating devices or replacing those existed boilers in commercial buildings makes great benefits in
economic and environmental prospects. With large capacity range from 10kW to
250kW, KOLANT commercial heat pumps provides various choices for users to get the most cost-effective solution for hot water projects.

Kolant hot water heat pump versatile Solution for Diverse Applications
Kolant heat pumps have gained extensive popularity across various fields, owing to the high – efficiency, energy – saving features, and environmental – friendliness.
In residential areas, whether it’s houses, flats, or villas, heat pumps can adapt to seasonal changes. They provide heating in winter and cooling in summer, reducing reliance on traditional fossil fuels and cutting down energy costs.
In the hospitality industry, hotels, inns, and clubs use heat pumps to maintain a comfortable indoor temperature, enhancing guests’ experiences. Public facilities like hospitals and airports, which demand strict temperature stability, can benefit from heat pumps’ precise temperature control. This not only meets their requirements but also significantly reduces energy consumption.
For factories, schools, and gymnasiums, heat pumps enable energy – efficient temperature regulation, improving the quality of the working and learning environment. Moreover, in special scenarios such as high – temperature disinfection, constant – temperature breeding centers, and swimming pool water heating, heat pumps play a crucial role. As technology advances, heat pumps will surely play an even more significant role in promoting green development across diverse industries.

The main heat pump and the hot water tank are independent. The water pipes are connected freely and simply, the heat pump can be hung on the wall or placed on the balcony/roof, and can be installed on 99% floors.

Multi-protection function built inside

Wider Operating Range

KOLANT hot heat pump can reliably and efficiently run with a bigger operating range. EVI model can working  with good efficiency at -30℃ ambient temperature. Normal heat pumps even can not work lower than -15 ℃ ambient temperature.

Your annual energy bill by different heating devices

 DC Inverter Heat pumpNormal ON/OFF Heat pumpGasDieselElectricity
Calorific value860kcal/kWh860kcal/kWh860kcal/kWh10,200kcal/L860kcal/kWh
Energy efficiency425%(A++)300%(A)85%85%95%
Energy price0.167€/kWh0.167€/kWh0.071€/kWh1.61€/L0.167€/kWh
Annual heating demand Qh25,445kWh25,445kWh25,445kWh25,445kWh25,445kWh
Annual energy consumption5,987kWh8,482kWh29,935kWh2,524L26,784kWh
Annual energy bill999.8€1,416.5€2,125.4€4,063.6€4,488.0€

Kolant Heat pump MORE saving than other devices

pool7 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

Smart WIFI control

By downloading our APP in your mobile phone, it is possible for you to conveniently control a DC inverter heat pump from KOLANT at any time, anywhere. Just imagine that you turn on your heat pump and set it to a comfortable temperature before you leave office, then you will enjoy the pleasant environment as soon as you get home, It is fantastic, isn’t it?

Intelligent LCD controller

The smart touch screen controller is friendly to all users, users can easily operate it without big effort. It is also very convenient for service people to check all the sensor data and the running state, set parameters with the aid of the controller.

High quality components, long lifetime

All the key components are from leading suppliers to make sure the quality and lifetime. For example, the DC inverter compressors are from Panasonic, the high efficiency plate heat exchangers are from Swep etc.

Intelligent compressor driver

Tube-in-shell condenser

Commerical heat pump axial fan

Scroll Compressor

Technical Data

 RJ-90HN2-BPDRJ-120HN2-BPDRJ-160HN2-BPDRJ-200HN2-BPD
ModelRJ-90H/N2-BPRJ-120H/N2-BPRJ-160H/N2-BPRJ-200H/N2-BPD
Performance data according to EN14511
Heating output/power input/COP at A7/W35kW/kW/-8.7/1.90/4.5812.0/2.70/4.4415.6/3.60/4.3319.5/4.61/4.23
Heating output/power input/COP at A2/W35kW/kW/-8.8/2.18/4.0411.5/2.90/3.9715.5/3.99/3.8819.6/5.12/3.83
Heating output/power input/COP at A-7/W35kW/kW/-7.1/2.39/2.979.3/3.08/3.0212.8/4.52/2.8316.3/5.78/2.82
Heating output/power input/COP at A7/W45kW/kW/-8.5/2.40/3.5411.4/3.12/3.6514.7/4.28/3.4318.8/5.52/3.41
Heating output/power input/COP at A-7/W45kW/kW/-6.8/2.87/2.379.0/3.74/2.4112.3/5.46/2.2514.7/6.46/2.28
Heating output/power input/COP at A7/W55kW/kW/-8.0/2.64/3.0310.8/3.53/3.0614.1/4.66/3.0317.6/5.99/2.94
Cooling output/power input/EER at A35/W7kW/kW/-7.1/2.50/2.849.6/3.30/2.9112.0/4.50/2.6715.1/5.89/2.56
Energy efficiency class according to EN14825
Average climate for floor heating A++A++A++A++
Average climate for radiator heating A++A++A++A++
Electrical data     
Power supply 230V/50Hz230V/50Hz230V/51Hz230V/52Hz
Maximum power consumptionkW3.74.866.8
Maximum input currentA16.22126.229.8
Application range
Water temperature rangeHeating18~6018~6118~6218~63
 Cooling8~288~298~308~31
Ambient air temperature rangeHeating-20~43-20~44-20~45-20~46
 Cooling15~4315~4415~4515~46
Other technical data
Type of refrigerant R410AR411AR412AR413A
Maximum operating pressureMPa4.25.26.27.2
Type of evaporator Fine-tubeFine-tubeFine-tubeFine-tube
Rated water flow ratem³/hR410AR411AR412AR413A
Internal water pressure lossKPa19202224
Diameter of water connectionmmDN25DN25DN32DN33
Noise level at 1 meterdB(A)54565758
Net dimensions (W*D*H)mm1115*450*926115*450*10761115*450*12761115*450*1480
Packing dimensions (W*D*H)mm1170*490*10551170*490*12051170*490*14201170*490*1620
Net/gross weightkg100/115120/138130/150150/170