Bomba de calor ar-água Trinity com reservatório de compensação interior

combined heating cooling and hot water heatpump
combined heating cooling and hot water heatpump

 

1.Central heating cooling and DHW with one AC buffer tank and expansion tank for easy installation.

2. With 2 circulation water pumps inside.  All water pumps will stop to save energy when room temp is reached.   All water pumps can start when room required.

3. Heating Cooling and domestic hot water multifunctional Heat Pump available for 17KW

3. Intelligent automatic operation mode of DHW and room heating for more energy saving during different ambient temp;

4. Intelligent auto defrost, antifreeze protection for low ambient temp operation to minus -15degree.

5. Real weekly timer-Different setting for every dayof the week to fit your life habit the most and save energy. Imaging you will enjoy your weekend in tourism with your sweet family, then the heat pump doesn’t need to start at weekend.  Weekly timer won’t loss memory after electricity cut off.

6.All error code can be checked through controller display which enable you to solve the problem as soon as possible.

Dados técnicos

Modelo n At air temp/outlet water temp AHP-17D-410S
Capacidade de aquecimento/potência de entrada (KW/KW) At A20ºC/W45ºC 18.5/4.63 4
At A7ºC/W45ºC 15.1/4.5 3.36
*At  A7ºC/W35ºC 16.95/3.96 4.28
At  A2ºC/W35ºC 14.79/4.0 3.7
Cooling Capcity/Input Power (KW/KW) At  A35ºC/W18ºC 17.8/4.8
Fonte de alimentação 230V or 380V/50HZ
available model for 60hz
Gama de trabalho ºC -15 ~ 43
Temperatura máxima da água de saída ºC 60
Mini-caudal de água
(Heating and cooling)
M3/h >=3
Junta de ligação de água mm DN25
Tamanho da embalagem mm 530*1280*1430
Tamanho da unidade mm 462*1190*1272
Classe de proteção IPx4
Classe anti-choque Classe 1
Refrigerante R410a
Ruído dB 45
Componente de regulação Emersão Válvula de expansão
Tipo de compressor Pergaminho
Aquecimento Arrefecimento permutador de calor Permutador de calor de placas
Quantidade de carga para 20’/40′ peças 21/42
Peso bruto kg 185
Nota:
1.  The above list all the data during different condition.  For example: AT A7ºC/W35ºC , means the test condition is air temp is 7 ºC, The Outlet water temp is 35ºC according to EN14511 standard.
2.2 circulation water pumps with 1 buffer tank inside. The 2 water pumps will be stopped when room temp reach target temp.

 

TEST UNDER European heat pump standard EN14511 STANDARD CONDITION