• Heat Pump Tech Since 1988! Contact us now for high quality heat pump!
  • info@china-heatpump.com
  • ru_RURussian
  • de_DEGerman
  • fr_FRFrench
  • en_USEnglish
KolantLogosssKolantLogoicoKolantLogosssKolantLogosss
  • Home
  • Kolant Heat Pumpmany kinds of heat pumps
    • Air to Water heat pump
      • R290 Inverter Multifunctional Monobloc heat pump
      • R32 inverter Heating Cooling DHW heat pump
      • Split EVI Inverter Heat Pump
      • Hot water heat pump
      • Swimming Pool Heat Pump
    • Geo-Water Source Heat Pump
      • R290 Inverter High Temp Geothermal Heat Pump
      • R32 inverter Geothermal Water Source Heat Pump
    • Multi Source Inverter Heat Pump
    • Solar PV hybrid eco heat pump
    • Multifunctional heat pump dryer
  • About Us
    • Awards
    • Warranty
    • Our Teams
    • Policy
    • Installation Reference
    • FAQ about our heat pump
  • Heat Pump News

Low ambient temp split heat pump-to replace gas boiler-9,11,15,18,23KW

  • Home
  • Special page heat pumps Featured Heat Pumps
  • Low ambient temp split heat pump-to replace gas boiler-9,11,15,18,23KW
Split Sanitary Hot Water Heat pump 3.5KW-5KW-8KW
08/24/2011
combined-heating-cooling-and-hot-water-heat-pump-17kw
09/17/2011
Categories
  • Featured Heat Pumps
  • Split EVI Inverter Heat Pump
Tags
  • air source heat pump
  • heat pump
  • Low temperature heat pump
  • replace gas boiler
  • split heat pump

Minus -35 ºC working heating-Kolant split heat pump

Best replacement for old gas boiler with Kolant split heat pump.

replace gas boiler with heat pump

Heating + Cooling + Domestic hot water in one solution. Similar function as popular split heat pump.
Can be working heating in super cold weather.
Low ambient temp heat pump heating in snowing weather

Products characters

1. It can provide air heating, air cooling and domestic hot water in one solution, similar function as LG Therma V and Daikin Altherma split heat pump.
2. It can utilize the existing water tank, radiator and other heating system and is idea equipment for home upgrading to energy saving house.
3. Built inside solar connection program enable solar for hot water and air heating together.
4. Excellent auto defrost for keeping heating during -20 centigrade.
even in electric power off accident, it still can keep no freeze for several days.
Special patent outdoor design to prevent the ice building during winter heating.
Built in crankcase heater to protect compressor during winter.
5. One water tank with expansion tank and backup electric heaters, other hydraulic components built inside
6. Timers on/off for you to choose the lowest electricity price period for operation to save your bill the most.
7. Parts are always choosen with the top brand in the world to assure quality, reliability and save maintenance cost.

Reliable Quality for saving maintenance cost:
  Our parts are always choosend with the top brand in the world
Heat exchanger: SU316 stainless plate heat exchanger.
The compressor: Daikin, Hitachi,Toshiba,Sanyo brand
Heat expansion valve: Emerson brand
Optional water pump: Wilo brand from Germany
Four way valve: Saginomiya brand of Japan
The above parts enable our heat pump to be trouble free products.

Kolant EVI split inverter heat pump specification:

Models Air temp/outlet water temp RJ85/N8-BPEEVI COP RJ-110H/N8-BPE COP RJ-150H/SN8-BPEEVI COP RJ-180H/SN8-BPEEVI COP RJ-230H/SN8-BPEEVI COP
Heating capacity/Power input (KW) at A20/W35°C 10.6/1.89 5.61 14.42/2.88 5.01 21.1/3.89 5.42 22.8/4.4 5.18 29.5/6.01 4.91
at A7/W35°C 8.59/1.87 4.59 10.6/2.55 4.16 14.7/3.31 4.44 18.8/4.4 4.27 23.1/5.34 4.33
at A7/W45°C 7.91/2.23 3.55 9.97/3.14 3.18 13.5/4.1 3.29 17.8/5.24 3.4 22.6/6.11 3.7
at A2/W35°C 7.65/1.81 4.23 9.54/2.49 3.83 13.08/3.21 4.07 16.92/4.31 3.93 20.29/5.38 3.77
at A2/W45°C 7.04/2.15 3.27 8.97/3.06 2.93 12.02/3.97 3.03 16/5.12 3.13 18.7/6.4 2.92
at A-12/W41°C 5.9/2.45 2.41 6.3/2.7 2.33 10.2/4.35 2.34 11.6/5.04 2.3 14.7/5.88 2.5
at A-20/W41°C 5.4/2.56 2.11 5.61/2.72 2.06 8.9/4.23 2.1 10.5/4.97 2.11 13.7/5.78 2.37
Cooling Capacity/Power input(KW) at A35/ W18ºC 9.2/2.7 3.41 11/3.3 3.33 13.9/4.2 3.31 15.6/4.8 3.25 20.1/6.2 3.24
at A35/W7ºC 7.2/2.73 2.64 8.6/3.4 2.53 9.8/3.77 2.6 10.5/4.2 2.5 13.5/5.09 2.65
Max.current                      (A) 18 19 28 14.3 18.1
Electric supply 230V/50~60HZ 400V/50~60HZ 400V/50~60HZ
Max.Outlet water temperature ( oC) 60
Running temperature range    (oC) -30 ~ 43
Refrigerant circuit Refrigerant R32
DC Inverter compressor MITSUBISHI MITSUBISHI MITSUBISHI MITSUBISHI MITSUBISHI
Heat exchanger Copper and Hydrauphilic Aluminum Fin
Air flow     (m3/h) 2400 5800 6000 7000
Water circuit Heat exchanger High efficiency tube in shell heat exchanger
In/Out pipe DN25(G1″) DN25(G1″) DN25(G1″) DN25(G1″) DN25(G1″)
Water flow  (m3/h) ≥1.5 ≥1.8 ≥2.5 ≥3 ≥3.9
permitted pressure ≤0.8MPa
Unit dimensions   WxHxD   (mm) 960*820*380 960*820*380 960*1270*380 960*1270*380 1030*1340*390
Pacage dimensions   WxHxD   (mm) 1040*940*502 1040*940*502 1040*1390*502 1040*1390*502 1115*1510*510
Net weight     (Kg) 68 68 108 108 128
Gross weight       (Kg) 85 85 125 125 145
Noise level        dB(A) 56 56 59 59 60
Loading quantity for 20’/40′ 44/88 44/88 22/44 22/44 22/44

Two Year Warranty !

We provide 1% free spareparts with containered order and 2 year warranty of main parts for factory fault since shipment arrival.
We will send the spare parts by courrier method after confirm it is due to factory fault.
We don’t cover the cost for failure from shipment, wrong installation and incorrect usage. Of course we can provide parts by customer’s cost after warranty period.

Customer Service

We can provide free heat pump installation consultation.

We can provide after sales service, technical assistant.
We can help to purchase other parts related to heat pumps or recommand reliable suppliers directly.

Shipping

For heat pump samples delivery, after packing with export class thick 5 layers paper box, we will pack heat pumps with poly wood case to avoid any damage as shown attached.

There are two ways to delivery the samples.
For sea freight, we will keep the refrigerant inside of the heat pump.
For air freight cargo, due to the air line regulation, we need to drain out the refrigerant. So you need to charge the refrigerant if you find the heat pump cannot start.
For all products above 50kg, we will fix it on a good structured wood or polywood pallet as shown below.

For Container delivery, we use only export thick 5 layer paper box. After carefully loading, we will take pictures before close the container door to assure everything is ok.

If by sea, normally we export at EXW, FOB or CFR terms, we only delivery goods to the destination sea port. The customers need to cover cost for their import duty and cost. Of course the customers can use our forwarder agent to help you to clear the customs.
We can provide all necessary document such as Form A, certificate of origin, Bill of lading, Invoice and packing list.

Normally it will take about 30 days by sea and one week by air.

Related posts

08/20/2025

Kolant EVI Inverter heat pump to replace boiler working at -35°C


Read more
07/15/2025

R290 inverter 70°C degree High temperature geo ground source water source Trinity Heat pump


Read more
10/22/2024

Kolant Split EVI Inverter heat pump won UL certificate


Read more
07/05/2024

Kolant heat pump Parts Comparation with F and Y brands


Read more

Send us Inquiry: Cancel reply

Your email address will not be published. Required fields are marked *

Our Address


Add:Area B, No. 6, Xinji Road East, Leyi Industrial Park, Nancun Town, Panyu District, Guangzhou,  China 511442

Tel: +86-020-31071023

Email:info@china-heatpump.com

Skype:chinaheatpump

Whatsapp:+8613719378805

Why Choose China Heat Pump

  • 1. Heating Cooling & DHW in one solution.
  • 2. Original European Heat Pump Technology
  • 3. Reliable with world Top Brand Parts
  • 4. All heat pumps can work intergratedly with solar heating
  • 5. With Wifi APP cloud control option for convenient control and maintenance
  • 6. Our Good Service

Recent Products

  • 0
    Kolant R290 Swimming Pool Heat Pump Heater
    09/18/2025
  • 0
    Kolant Heat Recovery Close loop heat pump Dryer-Most energy heat pump dryer
    09/10/2025
  • 0
    Open loop DC inverter ground water source heat pump with high COP
    09/01/2025

Contact us online





Your Name

Your Email

Your Message

Copyright © China heat pump Co.,Ltd-European style factory for heat pumps
Call our skype:chinaheatpump info@china-heatpump.com
  • Heat Pump Tech Since 1988! Contact us now for high quality heat pump!
  • info@china-heatpump.com
  • ru_RURussian
  • de_DEGerman
  • fr_FRFrench
  • en_USEnglish

Your Name

Your Email

Your Message