Inverter Pompe à chaleur géothermique à source d'eau
- COP 5.6~9.5
- Protocole Modbus est intégré pour être contrôlé par n'importe quel autre contrôleur modbus externe. Prise en charge de la commande centralisée.
- Source de chaleur : eau souterraine, eau de lac et même eau de mer.
- Fonctionne bien même si la température de l'air est inférieure à -45°C.
- Enery Class A+++ avec les réfrigérants R32 et R290
- Norme européenne inverseur de pompe à chaleur
- Avec contrôle Wifi fonction

The energy of the ground source heat pump system comes from the underground energy. It is considered to be currently the most environmentally friendly and most efficient heating and cooling system
- Most energy saving heat pump to utilize the Geothermal, underground water, lake water even sea water heat source.
- Work well in any super cold weather. No capacity loss in even minus -45°C air temp.
- Elegant and Compact size


European Technology control
Fuzzy Logic Intelligent Control to utilize solar heating for both domestic hot water and room heating. Automatically choose best water way to use solar heat, if solar heat is enough, the heat pump doesn’t start.
Wifi & Modbus
Additional 2nd Switch function interface enable to control the heat pump through any other thermostat or switch for convenient control.
Weekly on/off timers (different for each day) help to choose the lowest electricity price working time to save bill.
Wifi cloud remote control function to check heat pump status and control your heat pump on mobile phone.
Modbus protocol and RS485 port for your new controller and PC control
Routine Legionella function (Killing bacteria)


Weather compensation
Weather compensation auto target water temp curve according to different ambient temp.
A.AU curve translate is decided by parameter(F14) , positive value means move up, negative value means move down. (-15~15) B.AC AU heat curve highest temp is decided by parameter (F13), from 30~50, default 45.
High energy efficient
*High energy efficient:
La température du sol étant relativement stable, l'efficacité du transfert de chaleur des systèmes de pompes à chaleur géothermiques est très élevée. La consommation d'énergie est inférieure de 40~60% à celle des climatiseurs centraux et des chaudières à gaz.
* Respect de l'environnement et propreté.
Système de pompe à chaleur géothermique, pas de chaudière, pas de produits de combustion. Très propre et à faible émission de carbone.
* Confortable et peu bruyant.
Il s'agit d'un système à eau, la température est stable et confortable. Très peu bruyant car il fonctionne sans ventilateur.
* Multifunction.
Heating, cooling and hot water in one solution, heat recovery function is also available. One unit can satisty most of the demands.


Used widely
It can be widely used with all type of water sources. Lake, underground water,sea, and even wasted water
Open loop
The energy of the ground source heat pump system comes from the underground energy. It is considered to be currently the most environmentally friendly and most efficient heating and cooling system


Space saving
No need of cooling tower, boiler room and other outdoor equipments. Indoor fan coil system are also much slim than traditional VRF system.
*Flexiable and reliable operation. It can work for heating or hot water only, or A/C + DHW. Working condition is stable, no capacity decreasion even in the coldest winter.
Simple control
*Long lasting life time. working condition is very stable and mild, the lifetime of water source heat pump is much longer than A/C and boiler.
*Simple control and low maintance cost. The unit is automaticlly controled by the program,easy to operate. Working condition steable no over high or over low pressure problem.


Night mode to save energy
(1) Night mode can be set valid by parameter by user.
(2) The night mode starting time and stop time can be set in parameter.
(3) When night mode is valid, hot water mode will run with the current setting temp +3° C, room heating run with current setting -2°C. Room cooling run with current setting +2°C.
Automatic DHW water temp curve.
Real water temperature in the tank adapts automatically, based on the water set temp and the outdoor air temp. Additional energy savings.

Données techniques
| Modèle | SYRB-60ECH | SYRB-120ECH | SYRB-180ECH | ||
| Power supply | V/Hz/Ph | 220-240/50-60/1 | 220-240/50-60/1 | 220-240/50-60/1 | |
| Chauffage | Nominal capacity(W10/W35) | kW/h | 6.8 | 13.1 | 17.9 |
| Power input | KW | 1.26 | 2.4 | 3.3 | |
| COP | – | 5.4 | 5.46 | 5.42 | |
| Nominal capacity(W10/W55) | kW/h | 5.76 | 11.3 | 14.55 | |
| Power input | KW | 1.34 | 2.88 | 3.73 | |
| COP | – | 4.3 | 3.92 | 3.9 | |
| Capacité (B0/W35) | kW/h | 5.37 | 10.35 | 13.9 | |
| Power input | W | 1.22 | 2.33 | 3.2 | |
| COP | – | 4.4 | 4.44 | 4.34 | |
| De refroidissement | Nominal capacity(W30/W18) | kW/h | 4.1 | 11.1 | 15.2 |
| Power input | KW | 0.7 | 1.9 | 2.65 | |
| EER | – | 5.86 | 5.84 | 5.74 | |
| ECS | Nominal capacity | kW/h | 6.52 | 12.3 | 15.8 |
| Power input | KW | 1.28 | 2.78 | 3.61 | |
| COP | – | 5.09 | 4.42 | 4.38 | |
| Rated/Max.outlet water temp. | °C | 7~45/60 | |||
| Rated water flow rate | m3/h | 0.8 | 2 | 3 | |
| Contrôleur | Micro processor based digital wire controller with LCD display | ||||
| Compresseur | Type | – | Twin Rotary | ||
| Qté. | Nos. | 1 | |||
| Réfrigérant | – | R32 | |||
| Heat exchanger | – | Plate Heat Exchanger | |||
| Water connection | Entrée et sortie | pouce | 3/4″ | 1” | 1” |
| Noise level | dB(A) | 42 | 46 | 48 | |
| Net dimension | W*D*H | mm | 982*606*634 | 982*606*634 | 982*606*634 |
| Net weight | kg | 52 | 90 | 135 | |
The above data is based on the following testing condition under European EN14511 standard.
1.Heating: W10/W35= Water source inlet/outlet temperature 10°C/7°C; User side inlet/outlet temperature 30°C/35°C;
2. Heating:B0/W35 = Brine water source inlet/outlet temperature 0°C/-3°C; User side inlet/outlet temperature 30°C/35°C;
3.Cooling: Water source inlet/outlet temperature 30°C/35°C; User side inlet/outlet temperature 23°C/18°C;
4.Domestic Hot Water: Water source inlet temperature 10°C; Water temperature in the tank 45°C (Tank not included);