Инверторный тепловой насос с открытым контуром постоянного тока с высоким коэффициентом полезного действия

Inverter Геотермальный тепловой насос с водяным источником тепла

 
  • КС 5.6~9.5
  • Протокол Modbus встроен внутри и может управляться любым другим внешним контроллером modbus. Поддержка центрального управления.
  • Источник тепла - подземные воды, вода из озера и даже морская вода.
  • Хорошо работает даже при температуре воздуха -45°C.
  • Класс энергопотребления A+++ с хладагентом R32 и R290
  • Европейский стандарт инверторный тепловой насос
  • С управлением через Wi-Fi функция
 
Kolant-Geothermal-heat-pump34 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

The energy of the ground source heat pump system comes from the underground energy.  It is considered to be currently the most environmentally friendly and most efficient heating and cooling system

  1. Most energy saving heat pump to utilize the Geothermal, underground water, lake water  even sea water heat source.
  2. Work well in any super cold weather. No capacity loss in even minus -45°C air temp.
  3. Elegant and Compact size
Kolant-Geothermal-heat-pump4 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988
Kolant-Geothermal-heat-pump8 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

European Technology control

 

Fuzzy Logic Intelligent Control to utilize solar heating for both domestic hot water and room heating. Automatically choose best water way to use solar heat, if solar heat is enough, the heat pump doesn’t start.

Wifi & Modbus

 

Additional 2nd Switch function interface enable to control the heat pump through any other thermostat or switch for convenient control.

Weekly on/off timers (different for each day) help to choose the lowest electricity price working time to save bill.

Wifi cloud remote control function to check heat pump status and control your heat pump on mobile phone.

Modbus protocol and RS485 port for your new controller and PC control

Routine Legionella function (Killing bacteria) 

Kolant-Geothermal-heat-pump9 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988
Kolant-Geothermal-heat-pump17 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

Weather compensation

 

Weather compensation auto target water temp curve according to different ambient temp.

A.AU curve translate is decided by parameter(F14) , positive value means move up, negative value means move down. (-15~15) B.AC AU heat curve highest temp is decided by parameter (F13), from 30~50, default 45.

High energy efficient

 

*High energy efficient:

Поскольку температура почвы относительно стабильна, эффективность теплопередачи систем тепловых насосов с грунтовым источником тепла очень высока. Потребляемая мощность на 40~60% меньше, чем у центрального кондиционера и газового котла.

* Экологически чистые и безопасные.

Система теплового насоса с наземным источником тепла, без котла, без продуктов сгорания. Очень чистая и низкоуглеродная.

* Удобный и малошумный.

Это водяная система, температура в которой стабильна и комфортна. Супернизкий уровень шума, так как работает без обдува большим вентилятором.

* Multifunction.

Heating, cooling and hot water in one solution, heat recovery function is also available. One unit can satisty most of the demands.

water-to-water-heat-pump
Kolant Geothermal heat pump18 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

Used widely

 

It can be widely used with all type of water sources. Lake, underground water,sea, and even wasted water

Open loop

The energy of the ground source heat pump system comes from the underground energy. It is considered to be currently the most environmentally friendly and most efficient heating and cooling system

Kolant-Geothermal-heat-pump-231 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988
Kolant Geothermal-heat-pump-113 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

Space saving

 

No need of cooling tower, boiler room and other outdoor equipments. Indoor fan coil system are also much slim than traditional VRF system.

*Flexiable and reliable operation. It can work for heating or hot water only, or A/C + DHW. Working condition is stable, no capacity decreasion even in the coldest winter.

Simple control

*Long lasting life time. working condition is very stable and mild, the lifetime of water source heat pump is much longer than A/C and boiler.

*Simple control and low maintance cost. The unit is automaticlly controled by the program,easy to operate. Working condition steable no over high or over low pressure problem.

water-to-water-heat-pump | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988
Kolant-Geothermal-heat-pump161 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

Night mode to save energy

 

(1) Night mode can be set valid by parameter by user.

(2) The night mode starting time and stop time can be set in parameter.

(3) When night mode is valid, hot water mode will run with the current setting temp +3° C, room heating run with current setting -2°C. Room cooling run with current setting +2°C.

Automatic DHW water temp curve.

 

Real water temperature in the tank adapts automatically, based on the water set temp and the outdoor air temp. Additional energy savings.

Kolant-Geothermal-heat-pump10 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

Technique Data

 Модель SYRB-60ECHSYRB-120ECHSYRB-180ECH
Power supply В/Гц/Ф220-240/50-60/1220-240/50-60/1220-240/50-60/1
ОтоплениеNominal capacity(W10/W35)кВт/ч6.813.117.9
Power inputKW1.262.43.3
КС5.45.465.42
Nominal capacity(W10/W55)кВт/ч5.7611.314.55
Power inputKW1.342.883.73
КС4.33.923.9
Вместимость (B0/W35)кВт/ч5.3710.3513.9
Power inputW1.222.333.2
КС4.44.444.34
ОхлаждениеNominal capacity(W30/W18)кВт/ч4.111.115.2
Power inputKW0.71.92.65
EER5.865.845.74
ГВСNominal capacityкВт/ч6.5212.315.8
Power inputKW1.282.783.61
КС5.094.424.38
Rated/Max.outlet water temp.°C7~45/60
Rated water flow rateм³/ч0.823
Контроллер  Micro processor based digital wire controller with LCD display
КомпрессорТипTwin Rotary
Qty.Нос.1
 ХладагентR32
Heat exchanger Plate Heat Exchanger
Water connectionВход и выходдюйм3/4″1”1”
Noise level дБ(A)424648
Net dimensionШ*Д*Гмм982*606*634982*606*634982*606*634
Net weight кг5290135

The above data is based on the following testing condition under European EN14511 standard.
1.Heating: W10/W35= Water source inlet/outlet temperature 10°C/7°C; User side inlet/outlet temperature 30°C/35°C;
2. Heating:B0/W35 = Brine water source inlet/outlet temperature 0°C/-3°C; User side inlet/outlet temperature 30°C/35°C;
3.Cooling: Water source inlet/outlet temperature 30°C/35°C; User side inlet/outlet temperature 23°C/18°C;
4.Domestic Hot Water: Water source inlet temperature 10°C; Water temperature in the tank 45°C (Tank not included);

оставьте нам сообщение

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Прокрутить вверх
contact | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988
Получите предложение прямо сейчас!

    ваше имя

    Ваша электронная почта

    ваше сообщение