There is no doubt that air source heat pumps can make great economic and environmental benefits if they are properly used. However, as a matter of fact, most air source heat pumps work with very poor efficiency or even can not work when the environment temperature is lower than -10℃.
The EVI (enhanced vapor injection) heating technology indeed represents a significant innovation in the compressor and refrigerant circulation systems.
Kolant provides various capacities of EVI heat pumps for both residential or commercial applications. The heat pump can be used not only for heating in cold areas, but also for hot water or cooling as the optional function. They can be widely used for different purposes in different occasions.
The heating capacity of KOLANT EVI DC inverter heat pump can be precisely regulated from 20% to 100% according to the actual heat demand. Accordingly, the water temperature in the system will be steadily controlled with a very small deviation of no more than 0.5℃ so as to create a comfortable living environment.
KOLANT DC inverter heat pump can work under environment temperature -35℃
Obtenir une température de l'eau beaucoup plus élevée lorsque la température de l'environnement est basse
Heating capacity up to 40% higher than normal heat pumps
COP 10%-20% higher during low environment temperature
Kolant EVI heat pump has achieved an outstanding feat by attaining the prestigious energy class A+++ rating, as rigorously tested by TUV in accordance with the EN14825 and EU813 standards. This remarkable accomplishment underscores the pump’s unrivaled energy efficiency.
The EN14825 standard assesses heat pumps comprehensively, taking into account factors such as heating capacity, seasonal performance, and energy consumption under different operating conditions. By meeting this standard, Kolant EVI heat pump demonstrates its ability to provide consistent and reliable heating while consuming minimal energy.
The EU813 standard further validates the pump’s environmental friendliness and energy – saving capabilities. An A+++ energy class indicates that the Kolant EVI heat pump is among the top – tier, most energy – efficient models in the market. For consumers, this means significant savings on energy bills over time. Whether used in residential homes for cozy heating during winters or in commercial buildings to maintain a comfortable indoor climate, the Kolant EVI heat pump not only cuts down on electricity costs but also reduces the carbon footprint. It sets a high benchmark for the industry, proving that advanced technology can be harnessed to create products that are both powerful in performance and kind to the environment.
Kolant manufacture EVI heat pump capacity range 6KW~40kw of EVI heat pumps for both residential or commercial applications. The heat pump can provide Heating/cooling and domestic hot water in one solution.
Kolant heat pump built modbus protocol inside. Through the MODBUS protocol, operators gain comprehensive control. They can precisely regulate each heat pump’s temperature, ensuring a consistent indoor climate. Fan speeds can also be adjusted according to specific requirements, optimizing air circulation. By centralizing control over these 99 units, energy management becomes highly efficient. For instance, during periods of low demand, the system can be configured to run at reduced power, conserving energy while maintaining comfort levels. The maximum heating capacity of one system can be about 4,000kW via modbus control.
En téléchargeant notre application sur votre téléphone portable, il vous est possible de contrôler confortablement une pompe à chaleur DC inverter de KOLANT à tout moment et en tout lieu. Imaginez que vous allumez votre pompe à chaleur et que vous la réglez à une température confortable avant de quitter le bureau, puis que vous profitez d'un environnement agréable dès que vous rentrez chez vous, c'est fantastique, n'est-ce pas ?
The smart touch screen controller is friendly to all users, users can easily operate it without big effort. It is also very convenient for service people to check all the sensor data and the running state, set parameters with the aid of the controller.
All the key components are from leading suppliers to make sure the quality and lifetime. For example, the DC inverter compressors are from Panasonic, the high efficiency plate heat exchangers are from Swep etc
| Modèles | Température de l'air/température de l'eau à la sortie | RJ60H/N8-BPEEVI | COP | RJ85H/N8-BPEEVI | COP | RJ-110H/N8-BPE | COP | RJ-150H/SN8-BPEEVI | COP | RJ-180H/SN8-BPEEVI | COP | RJ-230H/SN8-BPEEVI | COP | RJ-300H/SN8- BPEEVI | COP | RJ-450H/SN8- BPEEVI | COP |
| Puissance calorifique / Puissance absorbée (KW/KW) | à A20/W35°C | 9.11/1.62 | 5.62 | 10.6/1.89 | 5.61 | 14.42/2.88 | 5.01 | 21.1/3.89 | 5.42 | 22.8/4.4 | 5.18 | 29.5/6.01 | 4.91 | 40.92/8.49 | 4.82 | 58.27/13.27 | 4.39 |
| à A7/W35°C | 6.7/1.45 | 4.62 | 8.59/1.87 | 4.59 | 10.6/2.55 | 4.16 | 14.7/3.31 | 4.44 | 18.8/4.4 | 4.27 | 23.1/5.34 | 4.33 | 31.6/7.8 | 4.05 | 45/12.2 | 3.69 | |
| à A7/W45°C | 6.2/1.55 | 4.00 | 7.91/2.23 | 3.55 | 9.97/3.14 | 3.18 | 13.5/4.1 | 3.29 | 17.8/5.24 | 3.4 | 22.6/6.11 | 3.7 | 29.12/9.27 | 3.14 | 41.47/14.5 | 2.86 | |
| à A2/W35°C | 6.16/1.45 | 4.25 | 7.65/1.81 | 4.23 | 9.54/2.49 | 3.83 | 13.08/3.21 | 4.07 | 16.92/4.31 | 3.93 | 20.29/5.38 | 3.77 | 29.07/7.79 | 3.73 | 41.4/12.21 | 3.39 | |
| à A2/W45°C | 5.58/1.52 | 3.67 | 7.04/2.15 | 3.27 | 8.97/3.06 | 2.93 | 12.02/3.97 | 3.03 | 16/5.12 | 3.13 | 18.7/6.4 | 2.92 | 26.5/9.17 | 2.89 | 37.74/14.35 | 2.63 | |
| à A-12/W41°C | 4.2/1.68 | 2.5 | 5.9/2.45 | 2.41 | 6.3/2.7 | 2.33 | 10.2/4.35 | 2.34 | 11.6/5.04 | 2.3 | 14.7/5.88 | 2.5 | 20.2/8.38 | 2.41 | 29.5/12.9 | 2.29 | |
| à A-20/W41°C | 3.85/2.1 | 1.83 | 5.4/2.56 | 2.11 | 5.61/2.72 | 2.06 | 8.9/4.23 | 2.1 | 10.5/4.97 | 2.11 | 13.7/5.78 | 2.37 | 18.5/8.73 | 2.12 | 26/13.7 | 1.9 | |
| Capacité de refroidissement / Puissance absorbée (KW/KW) | à A35/ W18ºC | 6.6/1.9 | 3.47 | 9.2/2.7 | 3.41 | 11/3.3 | 3.33 | 13.9/4.2 | 3.31 | 15.6/4.8 | 3.25 | 20.1/6.2 | 3.24 | 26/8.5 | 3.06 | 37.8/12.5 | 3.02 |
| à A35/W7ºC | 5.2/1.92 | 2.71 | 7.2/2.73 | 2.64 | 8.6/3.4 | 2.53 | 9.8/3.77 | 2.6 | 10.5/4.2 | 2.5 | 13.5/5.09 | 2.65 | 17.5/7.06 | 2.48 | 24/9.8 | 2.45 | |
| Max.current (A) | 13.2 | 18 | 19 | 28 | 14.3 | 18.1 | 16.7 | 24.2 | |||||||||
| Alimentation électrique | 230V/50~60HZ | 230V/50~60HZ | 400V/50~60HZ | 400V/50~60HZ | |||||||||||||
| Max.Outlet water temperature ( oC) | 60 | ||||||||||||||||
| Running temperature range (oC) | -35 ~ 43 | ||||||||||||||||
| Circuit frigorifique | Réfrigérant | R32 | |||||||||||||||
| Compresseur(s) DC Inverter | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | |||||||||
| Échange de chaleur | Ailettes en cuivre et aluminium hydrauphile | ||||||||||||||||
| Air flow (m3/h) | 2100 | 2400 | 2900 | 5800 | 6000 | 7000 | 9000 | 12000 | |||||||||
| Circuit d'eau | Échangeur de chaleur | Échangeur de chaleur à haute efficacité (tube dans enveloppe) | |||||||||||||||
| Tuyau d'entrée/sortie | DN20 | DN25(G1″) | DN25(G1″) | DN25(G1″) | DN25(G1″) | DN25(G1″) | DN32 | DN32 | |||||||||
| Water flow (m3/h) | >1 | ≥1.5 | ≥1.8 | ≥2.5 | ≥3 | ≥3.9 | >5 | >7 | |||||||||
| pression autorisée | ≤0.8MPa | ||||||||||||||||
| Unit dimensions WxHxD (mm) | 855*605*295 | 960*820*380 | 960*820*380 | 960*1270*380 | 960*1270*380 | 1030*1340*390 | 1066*1427*392 | 1185*1660*400 | |||||||||
| Pacage dimensions WxHxD (mm) | 935*725*420 | 1040*940*502 | 1040*940*502 | 1040*1390*502 | 1040*1390*502 | 1115*1510*510 | 1151*1597*512 | 1270*1830*520 | |||||||||
| Net weight (Kg) | 54 | 68 | 68 | 108 | 108 | 128 | 145 | 200 | |||||||||
| Gross weight (Kg) | 63 | 85 | 85 | 125 | 125 | 145 | 162 | 220 | |||||||||
| Noise level (dB(A)) | 54 | 56 | 56 | 59 | 59 | 60 | 62 | 65 | |||||||||
| Loading quantity for 20’/40′ (PCS) | 100/200 | 44/88 | 44/88 | 22/44 | 22/44 | 22/44 | 20/40 | 20/40 | |||||||||
Beaucoup plus avantageux pour la pluie et la neige.
Heating cooling and domestic hot water functions in one solution.
1. Optional Solar PV DC voltage connection, which enable more energy saving than other pompe à chaleur.
2. Mode de fonctionnement automatique intelligent de l'ECS et du chauffage de la pièce pour plus d'économie d'énergie en fonction de la température ambiante ;
3. Real weekly timer-Un réglage différent pour chaque jour de la semaine pour s'adapter au mieux à vos habitudes de vie et économiser de l'énergie. Si vous imaginez que vous allez profiter de votre week-end en tourisme avec votre famille, la pompe à chaleur n'a pas besoin d'être mise en marche le week-end.
4.All error code can be checked through controller display and mobile APP which enable you to solve the problem as soon as possible.