Kolant Multisource multifunctionele warmteterugwinning eco-warmtepomp om geo, koeltoren en luchtbron samen te gebruiken

Multi-Heat Source EVI Heat Recovery and Real Multifunctional Heat Pump

  • Real multifunctional heat pump, Room heating/cooling and DHW in the same time, no need waiting
  • New heat recovery tech to heat DHW water in both heating and cooling mode.
  • Use air source and geo water source together to increase efficiency.
  • Much more reliable than other multifunctional heat pump.
  • European standard inverter-warmtepomp
  • With Wifi control function
We hebben de certificaten:TUV ISO9001, ISO45001 (Health&Safety), ISO14001 (Environment), TUV EN14825 (A++), TUV CE, TUV CB, 38 patenten van product techniek, 66 Awards Certificaten van de overheid.
Multisource-MultifunctionConnection2 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

Two independent refrigerant system and New Heat Recovery system built inside Kolant Multisource heat recovery heat pump

Two compressors built inside with new heat recovery technology, combined with the essence of KOLANT’s more than 20 years of air-cooled heat pump design and heat recovery technology for cooling, heating and DHW function in one solution. The heat recovery function will start recover heat to domestic hot water in both cooling and heating mode.

AC heating/cooling and DHW function will work together, no need switching AC and DHW, so when require one function, no need to stop other function. The system is much more reliable than other multifunction heat pump switching system.

Kolant professional cooling solution use groundwater or cooling tower water through a combination of “water cooling + air cooling” . The water central cooling system has small air temperature difference with room temp, which makes the room air less dry and more comfortable.  The water central heating can use various room terminals such as undefloor heating system or radiators and creat a healthy living environment of “warm feet and cool roof”.

  • Solar ready: Compatible with solar thermal panels to be the second heat source of the system.
  • 0 cost free hot water: Domestic hot water is available all year round with free cost.
  • Healthy heating: Suitable for floor heating, radiator heating or fan coil heating.
  • Comfortable Cooling: Cooling function is available when it is necessary and suitable for fan coil  cooling or area cooling.
Multisourceheatrecoveryhp | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988
6Modes-245x300S | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

5+1 Working modes

Cooling only,Cooling+DHW,Heating only,Heating + DHW,DHW only,+Strong DHW mode

Kolant multi source heat recovery multifunctional heat pump adopts the latest full heat recovery technology from Spain, combining the essence of Kolant’s 20 years of air-cooled heat pump design and heat recovery technology. It meets the needs of both cooling and heating, and provides “free” domestic hot water around the clock during summer (with heat recovery during cooling). Compared to traditional household central air conditioning and hot water equipment, it saves over 40% in operating costs

Precise Heat Demand Match

The heating capacity of KOLANT DC inverter heat pump can be precisely regulated from 20% to 100% according to the actual heat demand. Accordingly, the water temperature in the system will be steadily controlled with a very small deviation of no more than 0.5℃ so as to create a comfortable living environment.

Inverter-Heating-Cooling-Heat-Pump-e1735115724398 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech
Inverter-Heating-Cooling-Heat-Pump3-e1735115762454 | | Kolant,professional Europe style heat pump factory,Mitsubishi tec

Wider Operating Range

KOLANT DC inverter heat pump can reliably and efficiently run with a bigger operating range. For example, even when the environment temperature as cold as -20℃ , the heat pump still can provide warm water with high water temperature and high heating output. However, normalheat pumps even can not work in this situation.

Energy efficiency class A+++

KOLANT DC inverter heating technology makes a very high energy efficiency within all the permitted operating range. For example, when the ambient air is not so cold and the heat demand is not so big, the heat pump runs with low heat output but a particularly high efficiency. However, when ambient air is extremely cold, the heat pump runs with full load to reduce or eliminate the aid of the booster heater. The intelligent control system is always trying to maximize the efficiency of the whole heating system. As a matter of fact, all KOLANT DC inverter heat pumps have energy efficiency class A+++.

Inverter-Heating-Cooling-Heat-Pump35 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

Heat Recovery Function is working at both Heating and Cooling mode to Save cost

HeatRecoveryforDHW | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

With 35 years experience in heat pump field, Kolant use the newest heat recovery tech in this Multisource heat recovery multifunctional heat pump.  The heat recovery can heat DHW(SHW) tank water to maximum 60°C in both cooling and heating mode. With free cost SHW water, it can also improve heating and cooling efficiency.

Multi function for heating cooling and DHW together

variousterminals | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

Professional cooling design to use geo or cooling tower

Creative design to combine water and air source together

water system temp difference small with stable water temp for more comfortable central air conditioning

water heating use underfloor heating to create warm feet and cool head for more healthy life

Compare Kolant Multisource heat recovery heat pump & others

ItemKolant Integrated Heat Recovery Multi-supplyAir Conditioner + Gas Water Heater
TypeIntegrated unitAir conditioning and water heating are independent devices
Cooling Air OutputAir output temperature 15-18°C, small temperature difference between supply and return air, gentle air supplyAir output temperature 7-12°C, large temperature difference between supply and return air, strong air supply
ComfortUses water system for cooling, small room temperature fluctuation, uses floor heating for heating, no dry indoor environment, excellent comfortUses refrigerant for cooling, large room temperature fluctuation, uses refrigerant heating, dry indoor environment, poor comfort
SafetyRefrigerant is sealed within the unit, only low-pressure water pipe in the room, stable and safe systemIndoor refrigerant pipe, prone to refrigerant leakage, water heater has the risk of natural gas leakage and explosion
MaintenanceEasy maintenance, easy to find leaks, water system pressure test, condensate drainage test, low maintenance costComplex system maintenance, difficult to find leaks, refrigerant leakage, high cost of recharge
Warm WaterProvided all year round, free hot water in summer, can use off-peak electricity to produce hot waterNo free hot water, high cost of hot water operation
Floor HeatingPossibleNot possible
Winter HeatingFloor heating and fan coil heating can be switched freely through indoor temperature controller, can achieve rapid heating and short-term heating without needing to turn on floor heating, more energy-efficientOnly air conditioning heating, poor heating comfort
Electromagnetic InterferenceNo electromagnetic interferenceHas electromagnetic interference
Energiebesparing40% energy saving/

Slimme WIFI-bediening

By downloading our APP in your mobile phone, it is possible for you to conveniently control a DC inverter heat pump from KOLANT at any time, anywhere. Just imagine that you turn on your heat pump and set it to a comfortable temperature before you leave office, then you will enjoy the pleasant environment as soon as you get home, It is fantastic, isn’t it?

Inverter-Heating-Cooling-Heat-Pump7 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988
tempcontrol-1 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

System Temp control

Kolant heat pump Temperature control system can adjust the outlet water temperature with room temperature controllers in different zones, which can be turned on and off as required, meet different temperature requirements and usage habits, and output on demand without waste.

Wide Working Range

Kolant Heat pumps stand out for their remarkable ability to operate stably in a wide range of ambient temperatures in both cooling and heating.
In summer, they deftly extract heat from indoor air, releasing it outside to cool the interior. When winter arrives, they reverse the process, drawing heat from the cold outside air and transferring it indoors for warmth. This adaptability is made possible by advanced compressors and intelligent controls. They adjust operation in response to temperature changes, ensuring consistent performance regardless of extreme heat or cold.

Wideworkingrange | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988
defrostcompareE | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

Kolant Intelligient Defrost

Kolant Intelligient Defrost function is a big step to improve heat pump performance. Through real-time monitoring of the heat pump working, the system in cold regions can perform intelligent defrosting based on the real-time operation to improve heating efficiency in winter.

Componenten van hoge kwaliteit, lange levensduur

All the key components are from leading suppliers to make sure the quality and lifetime. For example, the DC inverter compressors are from Panasonic, the high efficiency plate heat exchangers are from Swep etc.

Panasonic-compressor | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988
Kolant condenser | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988
Intelligent-compressor-driver | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988
ECFanmotor | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988
TwoEEVs | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

Volledig warmteterugwinningssysteem om warm water uit zonne-energie of grondwater te gebruiken voor ruimteverwarming en sanitair warm water.

Cool solar panel for higher efficency and use its heat for room in the same time. One side cooling or heating is free cost. 

Productfunctie:

Centrale verwarming, centrale koeling en sanitair warm water in één oplossing.

Zorg voor efficiënt warm water bij het verwarmen.
Productkenmerken:
1. Energiebesparende 50-60% vergeleken met traditionele airconditioner;
2. In de zomer produceren ze gratis warm water tijdens het koelen; in de winter worden warm water en centrale verwarming synchroon geproduceerd met een hoog rendement tot 5,0 ;
3. Suitable for -15c~+45 C ambient temperature;

4. Environment friendly: R410a refrigerant, no pollution, no waste discharge;

5. Economisch: De bedrijfskosten van de Kolant warmtepomp kunnen 85% lager zijn dan die van een traditioneel verwarmingssysteem met gasboiler;

6. Geavanceerde timerfunctie voor warmtepomp :
Zowel een ééndagstimer als een weektimer zijn beschikbaar. Kan voor elke dag van de hele week anders worden ingesteld.

Technische gegevens warmtepomp met warmteterugwinning:

ModelRJ-150H/N2BPEVI-50N2RJ-220H/N2BPEVI-50N2RJ-300H/SN2BPEVI-72N2RJ-400H/SN2BPEVI-72N2
Andere voorwaarde Warmteterugwinning toevoegen40Hz werking Warmteterugwinning toevoegen40Hz werking Warmteterugwinning toevoegen40Hz werking Warmteterugwinning toevoegen40Hz werking
stroomvoorziening1N-220V/50HZ3N-380V/50HZ3N-380V/50HZ3N-380V/50HZ
Nominale verwarming (W)180002200013200240002800016800335003800022800446004910029460
Nominaal verwarmingsvermogen (W)418041801760513051302310780078003510963096304333.5
COP4.315.267.54.685.467.274.294.876.54.635.16.8
Nominale verwarmingsstroom19A  23.3A  11.8 A  14.6 A  
Nominale koeling15000W  22000W  31000W  41000W  
Nominaal koelvermogen5003W  4760W  10470W  8950W  
Nominale koelstroom22.7A  21.6A  15.9A  13.6A  
Warm water5000W  5000W  7200W  7200W  
Nominaal warmwatervermogen1220W  1220W  1780W  1780W  
Nominale warmwaterstroom5.54A  5.54 A  8.09A  8.09A  
Maximaal ingangsvermogen (exclusief elektrische verwarming)7000W  7000W  14650W  14650W  
Maximale ingangsstroom (exclusief elektrische verwarming)31.8 A  31.8 A  31.8A  31.8A  
Nominaal circulatievolume van water voor airconditioning2500L/u  3500 L/u  5500 L/u  7000 L/u  
Warm water productie180 L/u  180 L/u  240 L/u  240 L/u  
koelmiddelR32  R32  R32  R32  
Type compressorTwee compressoren - één inverter + één aan/uit type (DHW)
warmtewisselaar waterzijdigPlaatuitwisseling + hoogefficiënte buis in shell warmtewisselaar
Interface warmwatertoevoerDN20 (3/4 “)
Interface warmwateruitlaatDN20 (3/4 “)
Waterinlaat airconditionerDN40 (1-1/4 “)
Wateruitlaat airconditionerDN40 (1-1/4 “)
Interface voor onderkoeld waterinlaat/  DN20 (3/4 “)  /  DN25 (1″)  
Waterkoeleruitlaat/  DN20 (3/4 “)  /  DN25 (1″)  
Maximale druk aan waterzijde0,6MPa
Minimumdruk aan waterzijde0,1 M p a (moet drukhoudend zijn)
Bedrijfsgeluid (dB(A))56  56  58  58  
Koudwaterinlaatdruk>=0,1 MPa

laat een bericht voor ons achter

Het e-mailadres wordt niet gepubliceerd. Vereiste velden zijn gemarkeerd met *

Scroll naar boven
contact | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988
Vraag nu een offerte aan!

    Uw Naam

    Uw E-Mail

    Uw Bericht