Geotermisk vannkildevarmepumpe med høy temperatur 145 ~ 210 kW

Geotermisk vannkildevarmepumpe med høy temperatur 145 ~ 210 kW

  • High-temperature industrial hot water
  • Outlet water  90°C temp.
  • Modbus protocol is built inside to be controlled by any other external modbus controller. Support central control.
  • Underground water, lake water  even sea water heat source.
  • European standard inverter varmepumpe

Vi har sertifikatene: TUV ISO9001, ISO45001 (helse og sikkerhet), ISO14001 (miljø), TUV EN14825 (A+++), TUV CE, TUV CB, 38 patenter på produktteknikk, 66 utmerkelser sertifikater fra regjeringen

Arbeidsprinsipp

Kolant-Geothermal-heat-pump34 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

The energy of the ground source heat pump system comes from the underground energy.  It is considered to be currently the most environmentally friendly and most efficient heating and cooling system

  1. Most energy saving heat pump to utilize the Geothermal, underground water, lake water  even sea water heat source.
  2. Work well in any super cold weather. No capacity loss in even minus -45°C air temp.
  3. Elegant and Compact size
Kolant-Geothermal-heat-pump4 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988
Kolant-Geothermal-heat-pump9 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

Wifi & Modbus

Additional 2nd Switch function interface enable to control the heat pump through any other thermostat or switch for convenient control.

Weekly on/off timers (different for each day) help to choose the lowest electricity price working time to save bill.

Wifi cloud remote control function to check heat pump status and control your heat pump on mobile phone.

Modbus protocol and RS485 port for your new controller and PC control

Routine Legionella function (Killing bacteria) .

Kolant Geothermal water source heatpump Benefits

High energy efficient

*High energy efficient:

As the soil temperature is relatively stable, ground source heat pump systems heat transfer efficiency is very high.The power consumption is 40~60% less than central air conditioner and gas boiler.

* Environmentally friendly and clean.

Ground source heat pump system, no boiler, no combustion products. Very clean and low-carbon.

* Comfortable and low noise.

It is a water system, the temperature is steable and comfortable. Super low noise as it works without big fan motor blowing.

* Multifunction.

Heating, cooling and hot water in one solution, heat recovery function is also available. One unit can satisty most of the demands.

High-Temperature-Geothermal-Water-Source-heat-pump7 | | Kolant,professional Europe style heat pump factory,Mitsubishi te
Kolant-Geothermal-heat-pump18 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

Used widely

It can be widely used with all type of water sources. Lake, underground water,sea, and even wasted water

Close loop

The energy of the ground source heat pump system comes from the underground energy. It is considered to be currently the most environmentally friendly and most efficient heating and cooling system

Kolant-Geothermal-heat-pump123 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

Kolant Geothermal water source heatpump strength

Space saving

 

No need of cooling tower, boiler room and other outdoor equipments. Indoor fan coil system are also much slim than traditional VRF system.

*Flexiable and reliable operation. It can work for heating or hot water only, or A/C + DHW. Working condition is stable, no capacity decreasion even in the coldest winter.

Kolant-Geothermal-heat-pump3 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988
| | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

Simple control

*Long lasting life time. working condition is very stable and mild, the lifetime of water source heat pump is much longer than A/C and boiler.

*Simple control and low maintance cost. The unit is automaticlly controled by the program,easy to operate. Working condition steable no over high or over low pressure problem.

Applications

It can produce hot water at high temperatures and has a wide range of applications, such as in high-temperature heating, high-temperature drying, high-temperature industrial manufacturing processes, and scenarios of waste heat or exhaust heat recovery, etc.

High-Temperature-Geothermal-Water-Source-heat-pump5 | | Kolant,professional Europe style heat pump factory,Mitsubishi te

Tekniske data

ModellSYRB-1500EH/SN3SYRB-2100EH/SN3
Heat Pump Operation 1 (Hot Water)Nominell varmekapasitet (kW)145210
Rated Heating Input Power (kW)4052
COP (Coefficient of Performance)3.634
Heat Pump Operation 2 (Hot Water)Nominell varmekapasitet (kW)115170
Rated Heating Input Power (kW)3650
COP (Coefficient of Performance)3.193.4
Heat Pump Operation 3 (Hot Water)Nominell varmekapasitet (kW)163220
Rated Heating Input Power (kW)3545
COP (Coefficient of Performance)4.654.89
Heat Pump Operation 4 (Hot Water)Nominell varmekapasitet (kW)123180
Rated Heating Input Power (kW)3243
COP (Coefficient of Performance)3.844.19
Heat Pump Operation 5 (Hot Water)Nominell varmekapasitet (kW)135
Rated Heating Input Power (kW)43
COP (Coefficient of Performance)3.14
KuldemediumTypeR515BR134a
System Number22
Control MethodMicrocomputerMicrocomputer
KompressorModellScrew TypeScrew Type
Quantity (Units x HP)2 (2X25HP)2 (2X25HP)
FordamperFormPlate TypePlate Type
Vannstrøm (m³/t)2030
Pressure Drop (kPa)5060
Water Inlet DiameterDN65DN65
Connection MethodExternal ThreadExternal Thread
KondensatorFormHigh Efficiency TubeHigh Efficiency Tube
Vannstrøm (m³/t)2536
Pressure Drop (kPa)5060
Water Inlet DiameterDN80DN80
Connection MethodFlangeFlange
Product Dimensions (L x W x H mm)1600x1200x12001600x1200x1200
Safety ProtectionHigh/Low Pressure/Anti-freeze/Overheat Protection
Machine Noise (dB(A))6566

Installasjonseksempler

CommercialWatersourceHeatpump3 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988
CommercialWatersourceHeatpump2 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988
CommercialWatersourceHeatpump1 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

legg igjen en beskjed til oss

Din e-postadresse vil ikke bli publisert. Obligatoriske felt er merket med *

Skroll til toppen
contact | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988
Få et tilbud nå!

    Ditt navn

    Din e-post

    Din melding