Direct access to any industrial waste water, domestic waste water, sea water.
Titanium Heat exchanger,special water source heat pump for open loop water, can use for directly access to all kinds of water source even working well with sea water. Extrimely easy installation for houses beside river,lake,sea!
Heating Cooling and domestic hot water functions available for HC series.
Waste water source heat pump single unit with slim size and reliable performance.
5 Times Energy Saving as Normal Gas or Petrol Heater.
Convient pour la zone Glaciale de la zone. Aucune perte de capacité dans le même -30 ° C la température de l'air.
Assez unité, sans voisin à se plaindre.
Personnages Principaux:
1. Extrimly energy saving, super cost saving with R410a gas inside.
2. Special open loop Titanium heat exchanger can use any water source even sea water source. The installation is easy and flexible.
3. Can be connected with solar water heater system.
4. All water access parts are stainless steel and copper to keep safe, healthy and non-pollution
Qualité, fiabilité et économiser les coûts de maintenance:
Nos pièces sont toujours choosend avec la marque de haut niveau dans le monde
Échangeur de chaleur: acier Inoxydable SU316 échangeur de chaleur à plaques.
Le compresseur: Daikin,Mitsubishi, Panasonic or Sanyo marque type de Défilement
La chaleur vanne d'expansion: Emerson marque
Quatre valve: Saginomiya marque du Japon
Les éléments ci-dessus permettent à notre pompe à chaleur pour le problème des produits gratuits.
Kolant Open Loop Waste water Source heat pump can be used as Heat Recovery Heat Pump to recover heat from room to heat the domestic hot water and swimming pool.
Directly access to swimming pool water with Titanium heat exchanger
Flexible installation of typical waste water source heat pump application:
Open loop water source heat pump can use all kinds of heat source from underground water source, under ground geothermal, lake water source, sea water source, river water source and waste water source.
Kolant Open Loop waste Water Source heat pump Well water application.
Geothermal Open Loop Well Water Source Heat Pump
Open loop water source Heat Pump from Lake, Pond,River and sea water
Open Loop Water Source Heat Pump to use cooling tower source.
Waste Water source heat pump parameter
Model No | OH-8 | OH-11 | OH-15 | OH-17 | OH-20S | OH-25S | OH-30S | ||
Chauffage | Nomical Capacity(W10ºC/W35ºC) | KW | 7.8 | 11 | 14.6 | 16.6 | 20.58 | 25.55 | 30 |
Power Input (W10ºC/W35ºC) | KW | 1.7 | 2.4 | 3.36 | 3.37 | 4.2 | 5.5 | 6.5 | |
COP(W10ºC/W35ºC) | KW/KW | 4.59 | 4.58 | 4.35 | 4.93 | 4.9 | 4.65 | 4.62 | |
Nomical Capacity(B0ºC/W35ºC) | KW | 6.8 | 8.5 | 12.2 | 13.4 | 17.30 | 21.00 | 25.4 | |
Power Input (B0ºC/W35ºC) | KW | 1.7 | 2.15 | 3.12 | 3.25 | 3.9 | 5.1 | 6.2 | |
COP(B0ºC/W35ºC) | KW/KW | 4 | 3.95 | 3.91 | 4.12 | 4.44 | 4.12 | 4.1 | |
De refroidissement | Nomical Capacity | KW | 8.2 | 11.2 | 15.09 | 16.9 | 20.5 | 25.3 | 30.5 |
Power Input | KW | 1.8 | 2.52 | 3.67 | 3.67 | 4.3 | 5.8 | 6.8 | |
EER | KW/KW | 4.56 | 4.44 | 4.11 | 4.6 | 4.77 | 4.36 | 4.49 | |
Alimentation | 220-230V/50HZ | ||||||||
Max Output water temp | ºC | 60 | |||||||
Mini water flow(L/H)(Water Source side) | Litre/Hour | 1800 | 2800 | 4000 | 5000 | 5800 | 7000 | 8500 | |
Mini water flow(L/H)(Heatpump side) | Litre/Hour | 1000 | 1750 | 2400 | 3000 | 3500 | 4300 | 5200 | |
Water source side Diameter(mm) | mm | DN25 | DN32 | ||||||
Heatpump side diameter(mm) | mm | DN25 | DN32 | ||||||
Packing size(mm) | L*H*W | mm | 650x1080x490 | 770x1130x580 | 770x1230x580 | ||||
Unit size(mm) | L*H*W | mm | 600x960x430 | 720x1010x520 | 720x1110x520 | ||||
Protection class | IPx4 | ||||||||
Anti Shock class | Class 1 | ||||||||
Refrigerant | R410a | ||||||||
Noise Level | dB | 29 | 30 | 31 | 32 | 33 | 34 | 36 | |
Regulation component | Emersion expansion valve | ||||||||
Condenser HX | Plate heat exchanger | ||||||||
Evaporator HX | Plate heat exchanger | ||||||||
Net weight | kg | 83 | 118 | 125 | 135 | 181 | 202 | 225 | |
Gross weight | kg | 88 | 123 | 130 | 140 | 186 | 217 | 230 |
We provide 1% free spareparts with containered order and 2 year warranty of main parts for factory fault since shipment arrival.
We will send the spare parts by courrier method after confirm it is due to factory fault.
We don’t cover the cost for failure from shipment, wrong installation and incorrect usage. Of course we can provide parts by customer’s cost after warranty period.
We can provide free heat pump installation consultation.
We can provide after sales service, technical assistant.
We can help to purchase other parts related to heat pumps or recommand reliable suppliers directly.
For heat pump samples delivery, after packing with export class thick 5 layers paper box, we will pack heat pumps with poly wood case to avoid any damage as shown attached.
There are two ways to delivery the samples.
For sea freight, we will keep the refrigerant inside of the heat pump.
For air freight cargo, due to the air line regulation, we need to drain out the refrigerant. So you need to charge the refrigerant if you find the heat pump cannot start.
For all products above 50kg, we will fix it on a good structured wood or polywood pallet as shown below.
Good pompe à chaleur packing and be careful with every details.
Polywood case packing and Pallet support for safety and no pollution.
For Container delivery, we use only export thick 5 layer paper box. After carefully loading, we will take pictures before close the container door to assure everything is ok.
If by sea, normally we export at EXW, FOB or CFR terms, we only delivery goods to the destination sea port. The customers need to cover cost for their import duty and cost. Of course the customers can use our forwarder agent to help you to clear the customs.
We can provide all necessary document such as Form A, certificate of origin, Bill of lading, Invoice and packing list.
Normally it will take about 30 days by sea and one week by air.