luxury fashion style water source heat pump,ground source heat pump

Heating Cooling Ground source/ Water source HeatPump single unit with slim size (7-60KW)
Water source heat pump Heat recovery is optional.
5 Times Energy Saving as Normal Gas or Petrol Heater.
Suitable for Frigid zone area. No capacity loss in even -30C air temp.
Quite unit, free of neighbour complain.
Personajes principales:
5. Extrimly energy saving, super cost saving with R410a gas inside.
6. Installation is easy and flexible.
8. Can be connected with solar water heater system.
9. All water access parts are stainless steel and copper to keep safe, healthy and non-pollution
Calidad para la fiabilidad y ahorrar costes de mantenimiento:
Our parts are always choosend with the top brand in the world
Intercambiador de calor: Intercambiador de calor de placas SU316 de acero inoxidable.
The compressor: Daikin brand Scroll type
Válvula de expansión térmica: Emerson marca
Water pump: Wilo brand from Germany (optional parts)
Válvula de cuatro vías: Saginomiya marca de Japón
Estas piezas permiten que nuestra bomba de calor sea un producto sin problemas.
Warer source heat pump (ground source heat pump) working theory diagram.

Flexible installation of typical water source heat pump application:
For Open Loop Water Source Heat Pump, please check our special open loop water source heat pump models at /open-loop-water-source-heat-pump-water-to-water-heat-pump-7-60kw.html

Geotermia Heat Pump for Lake, Pond and River

Geothermal Heat Pump Horizontal Ground loop

Bomba de calor geotérmica de bucle vertical
Water source heat pump parameter
| Modelo | GH-2 | GH-5 | GH-8 | GH-11 | GH-15 | GH-19 | GH-25 | GH-30 | ||
| Calefacción | Nomical Capacity (W10ºC/W35ºC) |
KW | 2 | 4.5 | 8.17 | 10.95 | 14.55 | 18.81 | 25.55 | 30 |
| Power Input (W10ºC/W35ºC) |
KW | 0.44 | 0.92 | 1.83 | 2.2 | 3.36 | 3.75 | 5.2 | 6.1 | |
| COP(W10ºC/W35ºC) | KW/KW | 4.55 | 4.89 | 4.46 | 4.98 | 4.33 | 5.02 | 4.91 | 4.92 | |
| Nomical Capacity (B0ºC/W35ºC) |
KW | 1.7 | 3.2 | 7.2 | 9.1 | 12.2 | 15.1 | 21.00 | 25.4 | |
| Power Input (B0ºC/W35ºC) |
KW | 0.42 | 0.8 | 1.8 | 2.25 | 3.12 | 3.5 | 4.80 | 5.8 | |
| COP(B0ºC/W35ºC) | KW/KW | 4.05 | 4 | 4 | 4.04 | 3.91 | 4.31 | 4.38 | 4.38 | |
| Refrigeración | Nomical Capacity | KW | 2.1 | 4.1 | 9.64 | 12.35 | 15.09 | 18.88 | 25.3 | 30.5 |
| Power Input | KW | 0.46 | 0.91 | 1.81 | 2.29 | 3.67 | 4.32 | 5.20 | 6.2 | |
| EER | KW/KW | 4.57 | 4.51 | 5.33 | 5.39 | 4.11 | 4.37 | 4.87 | 4.92 | |
| COP for heat recovery model | KW/KW | 7.3 | 7.52 | 7.83 | 8.3 | 6.75 | 7.51 | 7.82 | 7.87 | |
| Fuente de alimentación | 220-230V/50HZ | 380-415V/50hz | ||||||||
| Temperatura máxima del agua de salida | ºC | 60 | ||||||||
| Mini caudal de agua (Water Source side) |
Litre/Hour | 340 | 680 | 1000 | 1750 | 2400 | 3000 | 4300 | 5200 | |
| Mini caudal de agua (Heatpump side) |
Litre/Hour | 340 | 680 | 1000 | 1750 | 2400 | 3000 | 4300 | 5200 | |
| Water source side Diameter | mm | DN25 | DN20 | DN25 | DN32 | |||||
| Heatpump side diameter | mm | DN25 | DN20 | DN25 | DN32 | |||||
| Tamaño del embalaje (mm) | L*H*W | mm | 600x880x410 | 700×1080*460 | ||||||
| Tamaño de la unidad (mm) | L*H*W | mm | 550x760x350 | 650x960x400 | ||||||
| Clase de protección | IPx4 | |||||||||
| Clase antichoque | Clase 1 | |||||||||
| Refrigerante | R410a | |||||||||
| Noise Level | dB | 22 | 23 | 29 | 30 | 31 | 34 | 36 | ||
| Componente de regulación | Emersion expansion valve | |||||||||
| Condenser HX | Intercambiador de placas | |||||||||
| Evaporator HX | Intercambiador de placas | |||||||||
| Peso neto | kg | 28 | 35 | 73 | 108 | 115 | 125 | 192 | 215 | |
| Peso bruto | kg | 33 | 39 | 78 | 113 | 120 | 130 | 197 | 220 | |
Two Years Warranty !
We provide 1% free spare parts with container order and 2 year warranty of main parts for factory fault since shipment arrival.
We will send the spare parts by courier method after confirm it is due to factory fault.
We don’t cover the cost for failure from shipment, wrong installation and incorrect usage. Of course we can provide parts by customer’s cost after warranty period.
Atención al cliente
Le asesoramos gratuitamente sobre la instalación de una bomba de calor.
We can provide after sales service, technical assistant.
We can help to purchase other parts related to heat pumps or recommend reliable suppliers directly.
Envío
For heat pump samples delivery, after packing with export class thick 5 layers paper box, we will pack heat pumps with poly wood case to avoid any damage as shown attached.
There are two ways to delivery the samples.
For sea freight, we will keep the refrigerant inside of the heat pump.
For air freight cargo, due to the air line regulation, we need to drain out the refrigerant. So you need to charge the refrigerant if you find the heat pump cannot start.
For all products above 50kg, we will fix it on a good polywood pallet as shown below.
We use good bomba de calor packing and are careful with every details.

Polywood case packing and Pallet support for safety and no pollution.

For Container delivery, we use only export thick 5 layer paper box. After carefully loading, we will take pictures before close the container door to assure everything is ok.

If by sea, normally we export at EXW, FOB or CFR terms, we only delivery goods to the destination sea port. The customers need to cover cost for their import duty and cost. Of course the customers can use our forwarder agent to help you to clear the customs.
We can provide all necessary document such as Form A, certificate of origin, Bill of lading, Invoice and packing list.
Normally it will take about 30 days by sea and one week by air.



