Bomba de calor solar con accionamiento solar fotovoltaico directo sin batería

Kolant Solar PV direct drive Solar Heat Pump

Photovoltaic and network power are connected to heat pump power supply at the same time, and the green power is directly driven. No need inverter or transformer to change solar DC electricity to AC power. So the efficiency will be higher than normal heat pump. The green solar power can be tracked in real time and given priority. When the photovoltaic output is insufficient, the electricity network power can be automatically introduced to ensure the stability of the unit. When there is no solar electricity at all, it can be driven only by grid power, and the system can be intelligently controlled and supervised remotely. In the whole process, no need battery.

Kolant Cross-industry integrated new energy

uses innovative green energy modes such as solar power generation, wind energy storage and photovoltaic power storage with heat pump energy consumption, realizing seamless switching between dual power inputs, giving priority to photovoltaic energy without secondary conversion, greatly reducing the energy consumption . Kolant solar PV direct drive heat pump is the first choice for green energy saving.

Kolant Enthalpy-Increasing and Inverter technology

Ultra-low temperature and more energy-saving at -35℃ stable operation,
multi-energy integration scheme,
quieter and more comfortable,
multi-noise reduction,
less temperature fluctuation.

Kolant Solar PV direct drive solar heat pump Striking characters distinguishing from other products.

 

Sunny mode, zero electricity cost for cooling/heating and DHW.

When the weather is sunny, and the photovoltaic system can fully meet all the electricity demand, realizing “zero electricity fee” for cooling/heating. Intelligent compensation system for photovoltaic power generation in power grid

Cloudy mode, intelligent compensation, zero worry.

In rainy weather, when the sunshine is insufficient, the photovoltaic system provides a power grid to supplement photovoltaic power generation and sub-supply, and intelligently compensates the commercial power to ensure the stable operation of the unit.

Night mode, direct power supply from power grid.

During the night, the photovoltaic power generation system does not generate electricity, and the power grid compensates the power grid to supplement all the power supply of photovoltaic power generation, and the energy consumption is equivalent to that of the conventional inverter heat pump.

Wifi control

El sistema de control de la bomba de calor se puede controlar a distancia mediante APP móvil a través del servidor en la nube

Save Energy

Saves 75% power consumption compared with traditional electric water heater,0 cost during sunny day, .

Environmental

Environmentally-friendly refrigerants R410A/R32, and the COP energy efficiency ratio is as high as 10 when running at low speed.

Stable

The water and electricity are separated, and multiple protections are provided. It still runs stably in the cold climate of-35 C with ultra-low noise and a full DC fan motor, which has a longer service life.

All in one

The heat pump has a dedicated high-efficiency compressor to realize the three functions of heating, cooling and hot water.

Modbus

Incorpora el protocolo Modbus para que el distribuidor o el cliente puedan utilizar cualquier otro controlador para controlar la bomba de calor.

Bomba de calor solar fotovoltaica de accionamiento directo Especificación

Modelos Temperatura del aire/temperatura del agua de salidaGFRB-85H/N8 -BBPEEVICOPGFRB-110H/N8 -BBPEEVICOPGFRB-150H/N8 -BBPEEVICOPGFRB-185H/N8 -BBPEEVICOPGFRB-240H/N8 -BBPEEVICOP
Heating capacity/Power input (KW) a A20/W35°C10.6/1.895.6114.42/2.885.0121.1/3.895.4222.8/4.45.1829.5/6.014.91
a A7/W35°C8.59/1.874.5910.6/2.554.1614.7/3.314.4418.8/4.44.2723.1/5.344.33
a A7/W45°C7.91/2.233.559.97/3.143.1813.5/4.13.2917.8/5.243.422.6/6.113.7
a A2/W35°C7.65/1.814.239.54/2.493.8313.08/3.214.0716.92/4.313.9320.29/5.383.77
a A2/W45°C7.04/2.153.278.97/3.062.9312.02/3.973.0316/5.123.1318.7/6.42.92
a A-12/W41°C5.9/2.452.416.3/2.72.3310.2/4.352.3411.6/5.042.314.7/5.882.5
a A-20/W41°C5.4/2.562.115.61/2.722.068.9/4.232.110.5/4.972.1113.7/5.782.37
Cooling Capacity/Power input(KW) a A35/ W18ºC9.2/2.73.4111/3.33.3313.9/4.23.3115.6/4.83.2520.1/6.23.24
a A35/W7ºC7.2/2.732.648.6/3.42.539.8/3.772.610.5/4.22.513.5/5.092.65
Max.current  (A)18 19 28 14.3 18.1 
Max power input 4KW 5KW 6KW 7KW 9KW 
Solar working max voltage 340VDC
Suministro eléctrico 230V/50~60HZ400V/50~60HZ400V/50~60HZ
Max.Outlet water temperature60oC
Working temperature range (°C)-30 ~ 43
Circuito refrigerante Refrigerante R32
DC Inverter compressor MITSUBISHI MITSUBISHI MITSUBISHI MITSUBISHI MITSUBISHI 
Intercambio de calor Aleta de cobre y aluminio hidrófilo  
Air flow (m3/h) 2400   5800 6000 7000 
Circuito de agua Intercambiador de calor Intercambiador de calor de tubo en carcasa de alto rendimiento  
Inlet/Outlet pipe sizeDN25(G1″) DN25(G1″) DN25(G1″) DN25(G1″) DN25(G1″) 
Caudal de agua (m3/h)≥1.5 ≥1.8 ≥2.5 ≥3 ≥3.9 
presión permitida≤0,8MPa
Dimensiones de la unidad AnxAlxPr (mm) 960*820*380 960*820*380 960*1270*380 960*1270*380 1030*1340*390 
Pakage dimensions WxHxD (mm)1040*940*502 1040*940*502 1040*1390*502 1040*1390*502 1115*1510*510 
Peso neto (Kg) 68 68 108 108 128 
Peso bruto (Kg) 85 85 125 125 145 
Nivel de ruido (dB(A))56 56 59 59 60 
Loading quantity for 20’/40′ container44/88 44/88 22/44 22/44 22/44 

Referencia del proyecto de instalación de la bomba de calor Kolant