Kolant Multisource multifunksjonell øko-varmepumpe for varmegjenvinning som bruker geo, kjøletårn og luftkilde sammen

Multi-Heat Source EVI Heat Recovery and Real Multifunctional Heat Pump

  • Real multifunctional heat pump, Room heating/cooling and DHW in the same time, no need waiting
  • New heat recovery tech to heat DHW water in both heating and cooling mode.
  • Use air source and geo water source together to increase efficiency.
  • Much more reliable than other multifunctional heat pump.
  • European standard inverter varmepumpe
  • With Wifi control function
Vi har sertifikatene:TUV ISO9001, ISO45001 (helse og sikkerhet), ISO14001 (miljø), TUV EN14825 (A+++), TUV CE, TUV CB, 38 patenter på produktteknikk, 66 utmerkelser sertifikater fra regjeringen
Multisource-MultifunctionConnection2 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

Two independent refrigerant system and New Heat Recovery system built inside Kolant Multisource heat recovery heat pump

Two compressors built inside with new heat recovery technology, combined with the essence of KOLANT’s more than 20 years of air-cooled heat pump design and heat recovery technology for cooling, heating and DHW function in one solution. The heat recovery function will start recover heat to domestic hot water in both cooling and heating mode.

AC heating/cooling and DHW function will work together, no need switching AC and DHW, so when require one function, no need to stop other function. The system is much more reliable than other multifunction heat pump switching system.

Kolant professional cooling solution use groundwater or cooling tower water through a combination of “water cooling + air cooling” . The water central cooling system has small air temperature difference with room temp, which makes the room air less dry and more comfortable.  The water central heating can use various room terminals such as undefloor heating system or radiators and creat a healthy living environment of “warm feet and cool roof”.

  • Solar ready: Compatible with solar thermal panels to be the second heat source of the system.
  • 0 cost free hot water: Domestic hot water is available all year round with free cost.
  • Healthy heating: Suitable for floor heating, radiator heating or fan coil heating.
  • Comfortable Cooling: Cooling function is available when it is necessary and suitable for fan coil  cooling or area cooling.
Multisourceheatrecoveryhp | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988
6Modes-245x300S | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

5+1 Working modes

Cooling only,Cooling+DHW,Heating only,Heating + DHW,DHW only,+Strong DHW mode

Kolant multi source heat recovery multifunctional heat pump adopts the latest full heat recovery technology from Spain, combining the essence of Kolant’s 20 years of air-cooled heat pump design and heat recovery technology. It meets the needs of both cooling and heating, and provides “free” domestic hot water around the clock during summer (with heat recovery during cooling). Compared to traditional household central air conditioning and hot water equipment, it saves over 40% in operating costs

Nøyaktig tilpasning til varmebehovet

The heating capacity of KOLANT DC inverter heat pump can be precisely regulated from 20% to 100% according to the actual heat demand. Accordingly, the water temperature in the system will be steadily controlled with a very small deviation of no more than 0.5℃ so as to create a comfortable living environment.

Inverter-Heating-Cooling-Heat-Pump-e1735115724398 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech
Inverter-Heating-Cooling-Heat-Pump3-e1735115762454 | | Kolant,professional Europe style heat pump factory,Mitsubishi tec

Wider Operating Range

KOLANT DC inverter heat pump can reliably and efficiently run with a bigger operating range. For example, even when the environment temperature as cold as -20℃ , the heat pump still can provide warm water with high water temperature and high heating output. However, normalheat pumps even can not work in this situation.

Energy efficiency class A+++

KOLANT DC inverter heating technology makes a very high energy efficiency within all the permitted operating range. For example, when the ambient air is not so cold and the heat demand is not so big, the heat pump runs with low heat output but a particularly high efficiency. However, when ambient air is extremely cold, the heat pump runs with full load to reduce or eliminate the aid of the booster heater. The intelligent control system is always trying to maximize the efficiency of the whole heating system. As a matter of fact, all KOLANT DC inverter heat pumps have energy efficiency class A+++.

Inverter-Heating-Cooling-Heat-Pump35 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

Heat Recovery Function is working at both Heating and Cooling mode to Save cost

HeatRecoveryforDHW | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

With 35 years experience in heat pump field, Kolant use the newest heat recovery tech in this Multisource heat recovery multifunctional heat pump.  The heat recovery can heat DHW(SHW) tank water to maximum 60°C in both cooling and heating mode. With free cost SHW water, it can also improve heating and cooling efficiency.

Multi function for heating cooling and DHW together

variousterminals | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

Professional cooling design to use geo or cooling tower

Creative design to combine water and air source together

water system temp difference small with stable water temp for more comfortable central air conditioning

water heating use underfloor heating to create warm feet and cool head for more healthy life

Compare Kolant Multisource heat recovery heat pump & others

ItemKolant Integrated Heat Recovery Multi-supplyAir Conditioner + Gas Water Heater
TypeIntegrated unitAir conditioning and water heating are independent devices
Cooling Air OutputAir output temperature 15-18°C, small temperature difference between supply and return air, gentle air supplyAir output temperature 7-12°C, large temperature difference between supply and return air, strong air supply
ComfortUses water system for cooling, small room temperature fluctuation, uses floor heating for heating, no dry indoor environment, excellent comfortUses refrigerant for cooling, large room temperature fluctuation, uses refrigerant heating, dry indoor environment, poor comfort
SafetyRefrigerant is sealed within the unit, only low-pressure water pipe in the room, stable and safe systemIndoor refrigerant pipe, prone to refrigerant leakage, water heater has the risk of natural gas leakage and explosion
MaintenanceEasy maintenance, easy to find leaks, water system pressure test, condensate drainage test, low maintenance costComplex system maintenance, difficult to find leaks, refrigerant leakage, high cost of recharge
Varmt vann til husholdningenProvided all year round, free hot water in summer, can use off-peak electricity to produce hot waterNo free hot water, high cost of hot water operation
Floor HeatingPossibleNot possible
Winter HeatingFloor heating and fan coil heating can be switched freely through indoor temperature controller, can achieve rapid heating and short-term heating without needing to turn on floor heating, more energy-efficientOnly air conditioning heating, poor heating comfort
Electromagnetic InterferenceNo electromagnetic interferenceHas electromagnetic interference
Energy Saving40% energy saving/

Smart WIFI-kontroll

Ved å laste ned appen vår på mobiltelefonen din kan du enkelt styre en DC-inverter-varmepumpe fra KOLANT når som helst og hvor som helst. Tenk deg at du slår på varmepumpen og stiller den inn på en behagelig temperatur før du forlater kontoret, så kan du nyte et behagelig inneklima så snart du kommer hjem. Det er fantastisk, ikke sant?

Inverter-Heating-Cooling-Heat-Pump7 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988
tempcontrol-1 | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

System Temp control

Kolant heat pump Temperature control system can adjust the outlet water temperature with room temperature controllers in different zones, which can be turned on and off as required, meet different temperature requirements and usage habits, and output on demand without waste.

Bredt arbeidsområde

Kolant Heat pumps stand out for their remarkable ability to operate stably in a wide range of ambient temperatures in both cooling and heating.
In summer, they deftly extract heat from indoor air, releasing it outside to cool the interior. When winter arrives, they reverse the process, drawing heat from the cold outside air and transferring it indoors for warmth. This adaptability is made possible by advanced compressors and intelligent controls. They adjust operation in response to temperature changes, ensuring consistent performance regardless of extreme heat or cold.

Wideworkingrange | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988
defrostcompareE | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

Kolant Intelligient Defrost

Kolant Intelligient Defrost function is a big step to improve heat pump performance. Through real-time monitoring of the heat pump working, the system in cold regions can perform intelligent defrosting based on the real-time operation to improve heating efficiency in winter.

Komponenter av høy kvalitet, lang levetid

All the key components are from leading suppliers to make sure the quality and lifetime. For example, the DC inverter compressors are from Panasonic, the high efficiency plate heat exchangers are from Swep etc.

Panasonic-compressor | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988
Kolant condenser | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988
Intelligent-compressor-driver | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988
ECFanmotor | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988
TwoEEVs | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988

Fullt varmegjenvinningssystem for å utnytte solvarme eller grunnvannskilde til romoppvarming og varmt tappevann.

Cool solar panel for higher efficency and use its heat for room in the same time. One side cooling or heating is free cost. 

Produktfunksjon:

Sentralvarme, sentralkjøling og varmtvannsfunksjon i én og samme løsning.

Sørg for effektivt varmtvann ved oppvarming.
Produktkarakterer:
1. Energibesparende 50-60% sammenlignet med tradisjonelle klimaanlegg;
2. Om sommeren produseres gratis varmtvann ved kjøling; Om vinteren produseres varmtvann og sentralvarme synkront med høy virkningsgrad på opptil 5,0;
3. Egnet for -15c ~ +45 C omgivelsestemperatur;

4. Miljøvennlig: R410a kjølemiddel, ingen forurensning, ingen avfallsutslipp;

5. Økonomisk: Driftskostnadene for Kolant varmepumpe kan være 85% lavere enn for et tradisjonelt oppvarmingssystem med gasskjele;

6. avansert tidsinnstillingsfunksjon for varmepumpe :
Både enkeltdagstimer og ukentlig timer er tilgjengelig. Kan ha forskjellige innstillinger for hver dag i hele uken.

Tekniske data for varmepumpe med varmegjenvinning:

ModellRJ-150H/N2BPEVI-50N2RJ-220H/N2BPEVI-50N2RJ-300H/SN2BPEVI-72N2RJ-400H/SN2BPEVI-72N2
Annen tilstand Legg til varmegjenvinning40Hz arbeider Legg til varmegjenvinning40Hz arbeider Legg til varmegjenvinning40Hz arbeider Legg til varmegjenvinning40Hz arbeider
Strømforsyning1N-220V/50HZ3N-380V/50HZ3N-380V/50HZ3N-380V/50HZ
Nominell oppvarming (W)180002200013200240002800016800335003800022800446004910029460
Nominell varmeeffekt (W)418041801760513051302310780078003510963096304333.5
COP4.315.267.54.685.467.274.294.876.54.635.16.8
Nominell varmestrøm19A  23.3A  11.8 A  14.6 A  
Nominell kjøling15000W  22000W  31000W  41000W  
Nominell kjøleeffekt5003W  4760W  10470W  8950W  
Nominell kjølestrøm22.7A  21.6A  15.9A  13.6A  
Nominelt varmt vann5000W  5000W  7200W  7200W  
Nominell varmtvannseffekt1220W  1220W  1780W  1780W  
Nominell varmtvannsstrøm5.54A  5.54 A  8.09A  8.09A  
Maksimal tilført effekt (unntatt elektrisk oppvarming)7000W  7000W  14650W  14650W  
Maksimal inngangsstrøm (unntatt elektrisk oppvarming)31.8 A  31.8 A  31.8A  31.8A  
Nominelt sirkulasjonsvolum for vann til klimaanlegg2500 l/t  3500 l/t  5500 l/t  7000 l/t  
Produksjon av varmt vann180 l/t  180 l/t  240 l/t  240 l/t  
kjølemiddelR32  R32  R32  R32  
KompressortypeTo kompressorer - en inverter + en av/på-type (varmtvann)
varmeveksler på vannsidenPlateveksler + høyeffektiv rør i skallvarmeveksler
Grensesnitt for varmtvannsinntakDN20 (3/4 “)
Grensesnitt for varmtvannsuttakDN20 (3/4 “)
Vanninntak for klimaanleggDN40 (1-1/4 “)
Vannuttak for klimaanleggDN40 (1-1/4 “)
Grensesnitt for inntak av underkjølt vann/  DN20 (3/4 “)  /  DN25 (1″)  
Utløp for underkjølt vann/  DN20 (3/4 “)  /  DN25 (1″)  
Maksimalt trykk på vannsiden0,6 MPa
Minimumstrykk på vannsiden0,1 M p a (må være trykkbærende)
Støy under drift (dB(A))56  56  58  58  
Innløpstrykk for kaldt vann>=0,1 MPa

legg igjen en beskjed til oss

Din e-postadresse vil ikke bli publisert. Obligatoriske felt er merket med *

Skroll til toppen
contact | | Kolant,professional Europe style heat pump factory,Mitsubishi tech since 1988
Få et tilbud nå!

    Ditt navn

    Din e-post

    Din melding