Kolant central air conditioner with heat recovery free cost hot water heater,Cooling EER with heat recovery>6
The Kolant Central water air conditioner, integrated with a free heat recovery hot water heat pump, represents a revolutionary advancement in climate control technology, specifically tailored to the unique demands of the South Asian region. This cutting – edge system not only offers an optimal balance of affordability and performance but also addresses the region’s specific challenges, making it the ideal choice for both residential and commercial applications.
At the heart of the Kolant system lies its innovative dual – function design. It efficiently cools indoor spaces, creating a comfortable living and working environment even in the sweltering South Asian heat. Simultaneously, it recovers the heat expelled during the cooling process and utilizes it to heat water at no additional cost. This heat recovery mechanism is a game – changer, as it maximizes energy efficiency and reduces the overall energy consumption of households and businesses.
The system's energy - saving capabilities are truly remarkable.
With an input of just 1KW of electricity, it can generate an impressive 3KW of cooling capacity for room temperature regulation and an additional 3KW of heating power for hot water production. This translates to significant savings on energy bills, which is particularly crucial in South Asia, where rising energy costs are a growing concern for consumers and businesses alike.
By leveraging this advanced technology, the Kolant system not only helps users cut down on their energy expenses but also contributes to a more sustainable future by reducing carbon emissions.Another key advantage of the Kolant Central water air conditioner is its affordability.
Priced competitively, it makes high – end climate control technology accessible to a wider range of customers in South Asia. This means that even those with budget constraints can enjoy the benefits of a state – of – the – art air conditioning and hot water system without breaking the bank. Moreover, the low operation cost further enhances its economic appeal. The system’s energy – efficient components and intelligent design ensure that it consumes minimal power during operation, resulting in long – term savings that add up over time.
Kolant heat recovery air conditioner water heater suitable for electricity short supply area
In addition to its energy – saving and cost – effective features, the Kolant system is highly adaptable to the diverse energy landscapes of South Asia. Many areas in the region face issues of unstable electricity supply, which can disrupt daily life and business operations.
To address this, the Kolant system offers optional power supply solutions, including solar PV electricity supply and fuel generator power supply. In regions with abundant sunlight, the solar PV option allows users to harness the power of the sun to operate the system, reducing their reliance on the grid and minimizing the impact of power outages.
On the other hand, the fuel generator power supply option provides a reliable backup power source during extended blackouts, ensuring continuous operation of the air conditioner and hot water heat pump. This flexibility makes the Kolant system a reliable choice for any location in South Asia, regardless of the local power situation.
Cooling/Optional heating and domestic hot water in one solution
The Kolant Central water air conditioner with free heat recovery hot water heat pump is more than just a cooling and heating device; it is a comprehensive solution that meets the specific needs of the South Asian market. Its combination of affordability, low operation cost, high energy efficiency, and adaptable power supply options makes it the perfect choice for anyone looking to upgrade their climate control system.
Whether you are a homeowner seeking a more comfortable and cost – effective living environment or a business owner aiming to improve the efficiency and sustainability of your operations, the Kolant system is sure to exceed your expectations. Embrace the future of climate control with the Kolant Central water air conditioner and experience the difference for yourself.
Heating Cooling with Heat recovery water heat pump chiller specification
| Modelos | Temperatura do ar/temperatura da água de saída | RE-60HC/NB | RE-85HC/NB | RE-110HC/NB |
|---|---|---|---|---|
| Heating capacity/Power input (KW/KW) | a A20/W35°C | 9.11/1.62 COP 5.62 | 10.6/1.89 COP 5.61 | 15.23/2.7 COP 5.64 |
| a A7/W35°C | 6.71/1.45 COP 4.62 | 8.59/1.87 COP 4.59 | 11.22/2.41 COP 4.65 | |
| a A7/W45°C | 6.21/1.55 COP 4.00 | 7.91/2.23 COP 3.55 | 10.36/2.63 COP 3.94 | |
| a A2/W35°C | 6.16/1.45 COP 4.25 | 7.65/1.81 COP 4.23 | 10.32/2.41 COP 4.27 | |
| a A2/W45°C | 5.58/1.52 COP 3.67 | 7.04/2.15 COP 3.27 | 9.32/2.57 COP 3.63 | |
| at A-12/W41°C | 4.21/1.68 COP 2.5 | 5.9/2.45 COP 2.41 | 6.32/2.7 COP 2.33 | |
| at A-20/W41°C | 3.85/2.1 COP 1.83 | 5.4/2.56 COP 2.11 | 5.61/2.72 COP 2.06 | |
| Cooling Capacity+DHW Capacity/Power input (KW/KW) | at A35/W18°C | 9.6/1.6 COP 6 | 14.2/2.3 COP 6.17 | 17/2.7 COP 6.3 |
| at A35/W7°C | 8.2/1.62 COP 5.06 | 12.2/2.33 COP 5.24 | 14.62/2.75 COP 5.32 | |
| Max current (A) | 13.2 | 18 | 19 | |
| Alimentação eléctrica | 230V/50-60HZ | |||
| Max Outlet water temperature (°C) | 60 | 60 | 60 | |
| Running temperature range (°C) | Refrigerant R32/R410a | -15 ~ 43 | -15 ~ 43 | -15 ~ 43 |
| Circuito do refrigerante | DC Inverter compressor Heat exchanger | Mitsubishi | Mitsubishi | Mitsubishi |
| Air flow (m³/h) | Permutador de calor | 2100 | 2400 | 2900 |
| Circuito de água | Tubo de entrada/saída | DN20 | DN25(G1″) | DN25(G1″) |
| Water flow (m3/h) | >1 | ≥1.5 | ≥1.8 | |
| Permitted pressure | ≤0.8MPa | ≤0.8MPa | ≤0.8MPa | |
| Unit dimensions WxHxD (mm) | 855*605*295 | 960*820*380 | 960*820*380 | |
| Package dimensions WxHxD (mm) | 935*725*420 | 1040*940*502 | 1040*940*502 | |
| Net weight (Kg) | 54 | 68 | 68 | |
| Gross weight (Kg) | 63 | 85 | 85 | |
| Noise level (dB(A)) | 54 | 56 | 56 | |
| Loading quantity for 20’/40′ (PCS) | 100/200 | 44/88 | 44/88 |