{"id":1693,"date":"2013-06-28T15:03:37","date_gmt":"2013-06-28T07:03:37","guid":{"rendered":"\/?p=925"},"modified":"2025-12-03T16:06:47","modified_gmt":"2025-12-03T08:06:47","slug":"trinity-air-water-heat-pump-with-inner-buffer-tank","status":"publish","type":"post","link":"https:\/\/www.china-heatpump.com\/th\/trinity-air-water-heat-pump-with-inner-buffer-tank\/","title":{"rendered":"\u0e40\u0e04\u0e23\u0e37\u0e48\u0e2d\u0e07\u0e17\u0e33\u0e19\u0e49\u0e33\u0e2d\u0e38\u0e48\u0e19\u0e23\u0e30\u0e1a\u0e1a\u0e1b\u0e31\u0e4a\u0e21\u0e04\u0e27\u0e32\u0e21\u0e23\u0e49\u0e2d\u0e19\u0e2d\u0e32\u0e01\u0e32\u0e28-\u0e19\u0e49\u0e33 Trinity \u0e1e\u0e23\u0e49\u0e2d\u0e21\u0e16\u0e31\u0e07\u0e1a\u0e31\u0e1f\u0e40\u0e1f\u0e2d\u0e23\u0e4c\u0e20\u0e32\u0e22\u0e43\u0e19"},"content":{"rendered":"<p><img decoding=\"async\" alt=\"combined heating cooling and hot water heatpump\" src=\"\/UploadProductPic\/AH17D-buffer-tank-heat-pump.jpg \" \/><br \/>\n<strong><img decoding=\"async\" alt=\"combined heating cooling and hot water heatpump\" src=\"\/UploadProductPic\/combined%20heating%20cooling%20and%20hot%20water%20heatpump.jpg\" \/><\/strong><\/p>\n<p>&nbsp;<\/p>\n<p>1.Central heating cooling and DHW with one AC buffer\u00a0tank\u00a0and expansion tank for easy installation.<\/p>\n<p>2. With 2 circulation water pumps inside.\u00a0 All water pumps will stop to save energy when room temp is reached.\u00a0\u00a0 All water pumps can start when room required.<\/p>\n<p>3. Heating Cooling and domestic hot water multifunctional Heat Pump available for 17KW<\/p>\n<p>3. Intelligent automatic operation mode of DHW and room heating for more energy saving during different ambient temp;<\/p>\n<p>4. Intelligent auto defrost, antifreeze protection for low ambient temp operation to minus -15degree.<\/p>\n<p>5. Real weekly timer-Different setting for every dayof the week to fit your life habit the most and save energy. Imaging you will enjoy your weekend in tourism with your sweet family, then the heat pump doesn&#8217;t need to start at weekend.\u00a0 Weekly timer won&#8217;t loss memory after electricity cut off.<\/p>\n<p>6.All error code can be checked through controller display which enable you to solve the problem as soon as possible.<\/p>\n<p>\u0e02\u0e49\u0e2d\u0e21\u0e39\u0e25\u0e17\u0e32\u0e07\u0e40\u0e17\u0e04\u0e19\u0e34\u0e04<\/p>\n<table style=\"width: 635px; height: 663px;\" border=\"1\">\n<colgroup>\n<col width=\"167\" \/>\n<col width=\"178\" \/>\n<col width=\"195\" \/>\n<col width=\"53\" \/><\/colgroup>\n<tbody>\n<tr>\n<td width=\"167\" height=\"32\">Model No<\/td>\n<td width=\"178\">At air temp\/outlet water temp<\/td>\n<td width=\"195\">AHP-17D-410S<\/td>\n<td width=\"53\"><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" width=\"167\" height=\"84\">Heating Capcity\/Input Power (KW\/KW)<\/td>\n<td width=\"178\">At A20\u00baC\/W45\u00baC<\/td>\n<td width=\"195\">18.5\/4.63<\/td>\n<td width=\"53\">4<\/td>\n<\/tr>\n<tr>\n<td width=\"178\" height=\"21\">At A7\u00baC\/W45\u00baC<\/td>\n<td width=\"195\">15.1\/4.5<\/td>\n<td width=\"53\">3.36<\/td>\n<\/tr>\n<tr>\n<td width=\"178\" height=\"21\">*At\u00a0 A7\u00baC\/W35\u00baC<\/td>\n<td width=\"195\">16.95\/3.96<\/td>\n<td width=\"53\">4.28<\/td>\n<\/tr>\n<tr>\n<td width=\"178\" height=\"21\">At\u00a0 A2\u00baC\/W<span>35\u00baC<\/span><\/td>\n<td>14.79\/4.0<\/td>\n<td width=\"53\">3.7<\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"42\">Cooling Capcity\/Input Power (KW\/KW)<\/td>\n<td width=\"178\">At\u00a0 A35\u00baC\/W18\u00baC<\/td>\n<td width=\"195\">17.8\/4.8<\/td>\n<td width=\"53\"><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"167\" height=\"65\">\u0e41\u0e2b\u0e25\u0e48\u0e07\u0e08\u0e48\u0e32\u0e22\u0e44\u0e1f<\/td>\n<td width=\"178\"><\/td>\n<td width=\"195\">2<span>30V or <\/span><span>380V\/50HZ<\/span><\/td>\n<td width=\"53\"><\/td>\n<\/tr>\n<tr>\n<td width=\"178\" height=\"33\">available model for 60hz<\/td>\n<td width=\"195\"><\/td>\n<td width=\"53\"><\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"19\">Working Range<\/td>\n<td width=\"178\">\u0e2d\u0e07\u0e28\u0e32\u0e40\u0e0b\u0e25\u0e40\u0e0b\u0e35\u0e22\u0e2a<\/td>\n<td colspan=\"2\" width=\"248\">-15 ~ 43<\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"19\">Max Output water temp<\/td>\n<td width=\"178\">\u0e2d\u0e07\u0e28\u0e32\u0e40\u0e0b\u0e25\u0e40\u0e0b\u0e35\u0e22\u0e2a<\/td>\n<td colspan=\"2\" width=\"248\">60<\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"32\">Mini water flow<br \/>\n(Heating and cooling)<\/td>\n<td width=\"178\">M3\/h<\/td>\n<td width=\"195\">&gt;=3<\/td>\n<td width=\"53\"><\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"19\">Water connection joint<\/td>\n<td width=\"178\">\u0e21\u0e21<\/td>\n<td width=\"195\">DN25<\/td>\n<td width=\"53\"><\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"16\">\u0e02\u0e19\u0e32\u0e14\u0e1a\u0e23\u0e23\u0e08\u0e38<\/td>\n<td width=\"178\">\u0e21\u0e21<\/td>\n<td width=\"195\">530*1<span>2<\/span><span>80*1430<\/span><\/td>\n<td width=\"53\"><\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"20\">Unit size<\/td>\n<td width=\"178\">\u0e21\u0e21<\/td>\n<td width=\"195\">462*1<span>1<\/span><span>90*1272<\/span><\/td>\n<td width=\"53\"><\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"19\">\u0e23\u0e30\u0e14\u0e31\u0e1a\u0e01\u0e32\u0e23\u0e1b\u0e49\u0e2d\u0e07\u0e01\u0e31\u0e19<\/td>\n<td width=\"178\"><\/td>\n<td colspan=\"2\" width=\"248\">IPx4<\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"19\">\u0e23\u0e30\u0e14\u0e31\u0e1a\u0e01\u0e31\u0e19\u0e01\u0e23\u0e30\u0e41\u0e17\u0e01<\/td>\n<td width=\"178\"><\/td>\n<td colspan=\"2\" width=\"248\">\u0e0a\u0e31\u0e49\u0e19 1<\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"19\">\u0e2a\u0e32\u0e23\u0e17\u0e33\u0e04\u0e27\u0e32\u0e21\u0e40\u0e22\u0e47\u0e19<\/td>\n<td width=\"178\"><\/td>\n<td colspan=\"2\" width=\"248\">R410a<\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"16\">\u0e40\u0e2a\u0e35\u0e22\u0e07\u0e23\u0e1a\u0e01\u0e27\u0e19<\/td>\n<td width=\"178\">dB<\/td>\n<td width=\"195\">45<\/td>\n<td width=\"53\"><\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"38\">Regulation component<\/td>\n<td width=\"178\"><\/td>\n<td colspan=\"2\" width=\"248\">Emersion Expansion valve<\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"16\">\u0e1b\u0e23\u0e30\u0e40\u0e20\u0e17\u0e02\u0e2d\u0e07\u0e04\u0e2d\u0e21\u0e40\u0e1e\u0e23\u0e2a\u0e40\u0e0b\u0e2d\u0e23\u0e4c<\/td>\n<td width=\"178\"><\/td>\n<td colspan=\"2\" width=\"248\">\u0e40\u0e25\u0e37\u0e48\u0e2d\u0e19<\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"31\">Heating Cooling heat exchanger<\/td>\n<td width=\"178\"><\/td>\n<td colspan=\"2\" width=\"248\">Plate heat exchanger<\/td>\n<\/tr>\n<tr>\n<td height=\"28\">Loading quantity for 20&#8217;\/40&#8242;<\/td>\n<td>pcs<\/td>\n<td>21\/42<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td height=\"28\">Gross Weight<\/td>\n<td>k<span>\u0e08\u0e35<\/span><\/td>\n<td>185<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"345\" height=\"28\">Note:<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"345\" height=\"84\">1.\u00a0 The above list all the data during different condition.\u00a0 For example: AT A7\u00baC\/W35\u00baC , means the test condition is air temp is 7 \u00baC, The Outlet water temp is 35\u00baC according to EN14511 standard.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"345\" height=\"58\">2.2 circulation water pumps with 1 buffer tank inside. The 2 water pumps will be stopped when room temp reach target temp.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>TEST UNDER European heat pump standard EN14511 STANDARD CONDITION<\/p>","protected":false},"excerpt":{"rendered":"<p>&nbsp; 1.Central heating cooling and DHW with one AC buffer\u00a0tank\u00a0and expansion tank for easy installation. 2. With 2 circulation water pumps inside.\u00a0 All water pumps will stop to save energy when room temp is reached.\u00a0\u00a0 All water pumps can start when room required. 3. Heating Cooling and domestic hot water multifunctional Heat Pump available for<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>","protected":false},"author":2,"featured_media":4762,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[87],"tags":[155,171,172,99],"class_list":["post-1693","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-air-source-heat-pump","tag-air-water-heat-pump","tag-central-heating-cooling-heat-pump","tag-heat-pump-with-inner-buffer-tank","tag-multifunctional-heat-pump"],"_links":{"self":[{"href":"https:\/\/www.china-heatpump.com\/th\/wp-json\/wp\/v2\/posts\/1693","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.china-heatpump.com\/th\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.china-heatpump.com\/th\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.china-heatpump.com\/th\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.china-heatpump.com\/th\/wp-json\/wp\/v2\/comments?post=1693"}],"version-history":[{"count":1,"href":"https:\/\/www.china-heatpump.com\/th\/wp-json\/wp\/v2\/posts\/1693\/revisions"}],"predecessor-version":[{"id":4763,"href":"https:\/\/www.china-heatpump.com\/th\/wp-json\/wp\/v2\/posts\/1693\/revisions\/4763"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.china-heatpump.com\/th\/wp-json\/wp\/v2\/media\/4762"}],"wp:attachment":[{"href":"https:\/\/www.china-heatpump.com\/th\/wp-json\/wp\/v2\/media?parent=1693"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.china-heatpump.com\/th\/wp-json\/wp\/v2\/categories?post=1693"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.china-heatpump.com\/th\/wp-json\/wp\/v2\/tags?post=1693"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}