{"id":900,"date":"2011-09-25T12:01:37","date_gmt":"2011-09-25T04:01:37","guid":{"rendered":"\/?p=900"},"modified":"2025-11-13T15:28:54","modified_gmt":"2025-11-13T07:28:54","slug":"waste-water-source-heat-pump-with-titanium-heat-exchanger","status":"publish","type":"post","link":"https:\/\/www.china-heatpump.com\/nl\/waste-water-source-heat-pump-with-titanium-heat-exchanger\/","title":{"rendered":"Afval water warmtepomp met Titanium warmtewisselaar"},"content":{"rendered":"<p><strong>Direct access to any industrial waste water, domestic waste water, sea water. <\/strong><\/p>\n<p><strong>Titanium Heat exchanger,special water source heat pump for open loop water, can use for directly access to all kinds of water source even working well with sea water. Extrimely easy installation for houses beside river,lake,sea!<\/strong><\/p>\n<p><img decoding=\"async\" src=\"\/UploadProductPic\/openloop-watersourceheatpump.jpg\" alt=\"waste water source heat pump,ground source heat pump\" \/><\/p>\n<p><img decoding=\"async\" src=\"\/UploadProductPic\/watersource-heatpump-backview.jpg\" alt=\"waste water source heat pump,ground source heat pump\" \/><\/p>\n<p><strong>Heating Cooling \u00a0and domestic hot water functions available for HC series.<\/strong><\/p>\n<p><strong>\u00a0<strong><a href=\"\/nl\/Water-source-Heat-Pump-single-unit-5-30KW-product-179.html\/\">Waste water source heat pump<\/a><\/strong>\u00a0 single unit with slim size and reliable performance.<\/strong><\/p>\n<p><strong>\u00a0<\/strong>5 Times Energy Saving as Normal Gas or Petrol Heater.<\/p>\n<p><strong>Geschikt voor koude zones.  Geen capaciteitsverlies bij zelfs -30C luchttemperatuur.<\/strong><\/p>\n<p>Rustige eenheid, vrij van klachten van buren.<\/p>\n<p><strong>Hoofdpersonen:<\/strong><\/p>\n<p>1.\u00a0\u00a0 Extrimly energy saving, super cost saving with R32 or R290 gas inside.<\/p>\n<p>2.\u00a0\u00a0 Special open loop Titanium heat exchanger can use any water source even sea water source. The installation is easy and flexible.<\/p>\n<p>3.\u00a0\u00a0 Can be connected with solar water heater system.<\/p>\n<p>4.\u00a0\u00a0 All water access parts are stainless steel and copper to keep safe, healthy and non-pollution<\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>Kwaliteit voor betrouwbaarheid en bespaart kosten voor het onderhoud van:<\/strong><\/p>\n<p>Onze delen zijn altijd choosend met het hoogste merk in de wereld<\/p>\n<p>Warmtewisselaar: Roestvrijstalen SU316 platenwarmtewisselaar.<\/p>\n<p>De compressor:\u00a0<strong>Daikin,Mitsubishi, Panasonic or Sanyo<\/strong>\u00a0merk Scroll type<\/p>\n<p>Warmte expansie ventiel:\u00a0<strong>Emerson<\/strong>\u00a0merk<\/p>\n<p>Vier weg klep:\u00a0<strong>Saginomiya\u00a0<\/strong>merk van Japan<\/p>\n<p>De bovengenoemde onderdelen maken het mogelijk onze warmtepomp worden de problemen gratis producten.<\/p>\n<p><strong>Kolant Open Loop Waste water Source heat pump can be used as Heat Recovery Heat Pump to recover heat from room to heat the domestic hot water and swimming pool.<\/strong><\/p>\n<p><strong><br \/>\n<strong>Directly access to swimming pool water with Titanium heat \u00a0exchanger<\/strong><\/strong><br \/>\n<img decoding=\"async\" src=\"\/UploadProductPic\/heatrecovery-watersourceheatpump.jpg\" alt=\"heat recovery open loop water source heat pump diagram\" \/><\/p>\n<p><strong>Flexible installation of typical waste water source heat pump application:<\/strong><\/p>\n<p>Open loop water source heat pump can use all kinds of heat source from underground water source, under ground geothermal, lake water source, sea water source, river water source and waste water source.<\/p>\n<p><img decoding=\"async\" src=\"\/UploadProductPic\/openloop-watersource.jpg\" alt=\"open loop water source ground source heat pump vertical connection\" \/><\/p>\n<p><strong>Kolant Open Loop waste Water Source heat pump Well water application.<\/strong><\/p>\n<p><img decoding=\"async\" title=\"Kolant Openloop-watersource heat pump application\" src=\"\/UploadProductPic\/Openloop-watersource-application.jpg\" alt=\"Kolant Openloop-watersource heat pump application\" width=\"524\" \/><\/p>\n<p>Geothermal\u00a0Open Loop Well Water Source Heat Pump<\/p>\n<p><strong><img decoding=\"async\" src=\"\/UploadProductPic\/Open-pool-watersource-heatpump.jpg\" alt=\"water source ground source heat pump lake,pond and river application\" \/><\/strong><\/p>\n<p>Open loop water source\u00a0Heat Pump from Lake, Pond,River and sea water<\/p>\n<p><strong><img fetchpriority=\"high\" decoding=\"async\" title=\"water-source-heat-pump-with-cooling-tower\" src=\"\/UploadProductPic\/water-source-heat-pump-with-cooling-tower.jpg\" alt=\"water-source-heat-pump-with-cooling-tower\" width=\"297\" height=\"229\" \/><\/strong><\/p>\n<p>Open Loop Water Source Heat Pump to use cooling tower source.<\/p>\n<p><strong>Waste Water source heat pump parameter<\/strong><\/p>\n<table style=\"width: 562px; height: 558px;\" border=\"1\" width=\"562\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"153\" \/>\n<col width=\"201\" \/>\n<col width=\"74\" \/>\n<col span=\"6\" width=\"65\" \/>\n<col width=\"65\" \/><\/colgroup>\n<tbody>\n<tr>\n<td width=\"153\" height=\"17\">Modelnr.<\/td>\n<td width=\"201\"><\/td>\n<td width=\"74\"><\/td>\n<td width=\"65\">OH-8<\/td>\n<td width=\"65\">OH-11<\/td>\n<td width=\"65\">OH-15<\/td>\n<td width=\"65\">OH-17<\/td>\n<td width=\"65\">OH-20S<\/td>\n<td width=\"65\">OH-25S<\/td>\n<td width=\"65\">OH-30S<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\" height=\"102\">Verwarming<\/td>\n<td>Nomical Capacity(W10\u00baC\/W35\u00baC)<\/td>\n<td>KW<\/td>\n<td width=\"65\">7.8<\/td>\n<td width=\"65\">11<\/td>\n<td width=\"65\">14.6<\/td>\n<td width=\"65\">16.6<\/td>\n<td>20.58<\/td>\n<td>25.55<\/td>\n<td width=\"65\">30<\/td>\n<\/tr>\n<tr>\n<td height=\"17\">Vermogen (W10\u00baC\/W35\u00baC)<\/td>\n<td>KW<\/td>\n<td width=\"65\">1.7<\/td>\n<td width=\"65\">2.4<\/td>\n<td width=\"65\">3.36<\/td>\n<td width=\"65\">3.37<\/td>\n<td>4.2<\/td>\n<td>5.5<\/td>\n<td width=\"65\">6.5<\/td>\n<\/tr>\n<tr>\n<td height=\"17\">AGENT (W10\u00baC\/W35\u00baC)<\/td>\n<td>KW\/KW<\/td>\n<td width=\"65\">4.59<\/td>\n<td width=\"65\">4.58<\/td>\n<td width=\"65\">4.35<\/td>\n<td width=\"65\">4.93<\/td>\n<td width=\"65\">4.9<\/td>\n<td width=\"65\">4.65<\/td>\n<td width=\"65\">4.62<\/td>\n<\/tr>\n<tr>\n<td height=\"17\">Nomical Capacity(B0\u00baC\/W35\u00baC)<\/td>\n<td>KW<\/td>\n<td width=\"65\">6.8<\/td>\n<td width=\"65\">8.5<\/td>\n<td width=\"65\">12.2<\/td>\n<td width=\"65\">13.4<\/td>\n<td>17.30<\/td>\n<td>21.00<\/td>\n<td width=\"65\">25.4<\/td>\n<\/tr>\n<tr>\n<td height=\"17\">Vermogen (B0\u00baC\/W35\u00baC)<\/td>\n<td>KW<\/td>\n<td width=\"65\">1.7<\/td>\n<td width=\"65\">2.15<\/td>\n<td width=\"65\">3.12<\/td>\n<td width=\"65\">3.25<\/td>\n<td>3.9<\/td>\n<td>5.1<\/td>\n<td width=\"65\">6.2<\/td>\n<\/tr>\n<tr>\n<td height=\"17\">AGENT (B0\u00baC\/W35\u00baC)<\/td>\n<td>KW\/KW<\/td>\n<td width=\"65\">4<\/td>\n<td width=\"65\">3.95<\/td>\n<td width=\"65\">3.91<\/td>\n<td width=\"65\">4.12<\/td>\n<td width=\"65\">4.44<\/td>\n<td width=\"65\">4.12<\/td>\n<td width=\"65\">4.1<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" height=\"51\">Koeling<\/td>\n<td>Nomical Capacity<\/td>\n<td>KW<\/td>\n<td width=\"65\">8.2<\/td>\n<td width=\"65\">11.2<\/td>\n<td width=\"65\">15.09<\/td>\n<td width=\"65\">16.9<\/td>\n<td>20.5<\/td>\n<td>25.3<\/td>\n<td width=\"65\">30.5<\/td>\n<\/tr>\n<tr>\n<td height=\"17\">Power Input<\/td>\n<td>KW<\/td>\n<td width=\"65\">1.8<\/td>\n<td width=\"65\">2.52<\/td>\n<td width=\"65\">3.67<\/td>\n<td width=\"65\">3.67<\/td>\n<td>4.3<\/td>\n<td>5.8<\/td>\n<td width=\"65\">6.8<\/td>\n<\/tr>\n<tr>\n<td height=\"17\">EER<\/td>\n<td>KW\/KW<\/td>\n<td width=\"65\">4.56<\/td>\n<td width=\"65\">4.44<\/td>\n<td width=\"65\">4.11<\/td>\n<td width=\"65\">4.6<\/td>\n<td width=\"65\">4.77<\/td>\n<td width=\"65\">4.36<\/td>\n<td width=\"65\">4.49<\/td>\n<\/tr>\n<tr>\n<td width=\"153\" height=\"37\">Voeding<\/td>\n<td width=\"201\"><\/td>\n<td width=\"74\"><\/td>\n<td colspan=\"4\" width=\"195\">220-230V\/50HZ<\/td>\n<td colspan=\"3\" width=\"195\"><\/td>\n<\/tr>\n<tr>\n<td width=\"153\" height=\"20\">Max. temp uitgangswater<\/td>\n<td width=\"201\"><\/td>\n<td width=\"74\">\u00baC<\/td>\n<td colspan=\"7\" width=\"390\">60<\/td>\n<\/tr>\n<tr>\n<td width=\"153\" height=\"36\">Mini water flow(L\/H)(Water Source side)<\/td>\n<td width=\"201\"><\/td>\n<td width=\"74\">Litre\/Hour<\/td>\n<td width=\"65\">1800<\/td>\n<td width=\"65\">2800<\/td>\n<td width=\"65\">4000<\/td>\n<td width=\"65\">5000<\/td>\n<td width=\"65\">5800<\/td>\n<td width=\"65\">7000<\/td>\n<td width=\"65\">8500<\/td>\n<\/tr>\n<tr>\n<td width=\"153\" height=\"20\">Mini water flow(L\/H)(Heatpump side)<\/td>\n<td width=\"201\"><\/td>\n<td width=\"74\">Litre\/Hour<\/td>\n<td width=\"65\">1000<\/td>\n<td width=\"65\">1750<\/td>\n<td width=\"65\">2400<\/td>\n<td width=\"65\">3000<\/td>\n<td width=\"65\">3500<\/td>\n<td width=\"65\">4300<\/td>\n<td width=\"65\">5200<\/td>\n<\/tr>\n<tr>\n<td width=\"153\" height=\"20\">Water source side Diameter(mm)<\/td>\n<td width=\"201\"><\/td>\n<td width=\"74\">mm<\/td>\n<td colspan=\"4\" width=\"195\">DN25<\/td>\n<td colspan=\"3\" width=\"195\">DN32<\/td>\n<\/tr>\n<tr>\n<td width=\"153\" height=\"20\">Heatpump side diameter(mm)<\/td>\n<td width=\"201\"><\/td>\n<td width=\"74\">mm<\/td>\n<td colspan=\"5\" width=\"260\">DN25<\/td>\n<td colspan=\"2\" width=\"130\">DN32<\/td>\n<\/tr>\n<tr>\n<td width=\"153\" height=\"20\">Verpakkingsgrootte (mm)<\/td>\n<td width=\"201\">L*H*B<\/td>\n<td width=\"74\">mm<\/td>\n<td width=\"65\">650x1080x490<\/td>\n<td colspan=\"2\" width=\"130\">770x1130x580<\/td>\n<td colspan=\"4\" width=\"260\">770x1230x580<\/td>\n<\/tr>\n<tr>\n<td width=\"153\" height=\"20\">Unit size(mm)<\/td>\n<td width=\"201\">L*H*B<\/td>\n<td width=\"74\">mm<\/td>\n<td width=\"65\">600x960x430<\/td>\n<td colspan=\"2\" width=\"130\">720x1010x520<\/td>\n<td colspan=\"4\" width=\"260\">720x1110x520<\/td>\n<\/tr>\n<tr>\n<td width=\"153\" height=\"20\">Beschermingsklasse<\/td>\n<td width=\"201\"><\/td>\n<td width=\"74\"><\/td>\n<td colspan=\"7\" width=\"390\">IPx4<\/td>\n<\/tr>\n<tr>\n<td width=\"153\" height=\"20\">Anti-schok klasse<\/td>\n<td width=\"201\"><\/td>\n<td width=\"74\"><\/td>\n<td colspan=\"7\" width=\"390\">Klasse 1<\/td>\n<\/tr>\n<tr>\n<td width=\"153\" height=\"20\">Koelmiddel<\/td>\n<td width=\"201\"><\/td>\n<td width=\"74\"><\/td>\n<td colspan=\"7\" width=\"390\">R32<\/td>\n<\/tr>\n<tr>\n<td width=\"153\" height=\"20\">Geluidsniveau<\/td>\n<td width=\"201\"><\/td>\n<td width=\"74\">dB<\/td>\n<td width=\"65\">29<\/td>\n<td width=\"65\">30<\/td>\n<td width=\"65\">31<\/td>\n<td width=\"65\">32<\/td>\n<td width=\"65\">33<\/td>\n<td width=\"65\">34<\/td>\n<td width=\"65\">36<\/td>\n<\/tr>\n<tr>\n<td width=\"153\" height=\"24\">Onderdeel regelgeving<\/td>\n<td width=\"201\"><\/td>\n<td width=\"74\"><\/td>\n<td colspan=\"7\" width=\"390\">Emersion expansion valve<\/td>\n<\/tr>\n<tr>\n<td width=\"153\" height=\"17\">Condenser HX<\/td>\n<td width=\"201\"><\/td>\n<td width=\"74\"><\/td>\n<td colspan=\"7\" width=\"390\">Plate heat exchanger<\/td>\n<\/tr>\n<tr>\n<td width=\"153\" height=\"17\">Evaporator HX<\/td>\n<td width=\"201\"><\/td>\n<td width=\"74\"><\/td>\n<td colspan=\"7\" width=\"390\">Plate heat exchanger<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">Nettogewicht<\/td>\n<td><\/td>\n<td>kg<\/td>\n<td align=\"right\">83<\/td>\n<td align=\"right\">118<\/td>\n<td align=\"right\">125<\/td>\n<td align=\"right\">135<\/td>\n<td align=\"right\">181<\/td>\n<td align=\"right\">202<\/td>\n<td align=\"right\">225<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">Brutogewicht<\/td>\n<td><\/td>\n<td>kg<\/td>\n<td align=\"right\">88<\/td>\n<td align=\"right\">123<\/td>\n<td align=\"right\">130<\/td>\n<td align=\"right\">140<\/td>\n<td align=\"right\">186<\/td>\n<td align=\"right\">217<\/td>\n<td align=\"right\">230<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Two Year Warranty!<\/h3>\n<p>Wij bieden 1% gratis reserveonderdelen met gecontainerede bestelling en 2 jaar garantie van de belangrijkste onderdelen voor fabrieksfouten sinds de aankomst van de zending.<\/p>\n<p>We sturen de reserveonderdelen per koerier nadat we hebben bevestigd dat het om een fabrieksfout gaat.<\/p>\n<p>We dekken geen kosten voor defecten bij verzending, verkeerde installatie en onjuist gebruik. Natuurlijk kunnen we onderdelen leveren op kosten van de klant na de garantieperiode.<\/p>\n<h3>Klantenservice<\/h3>\n<p>We kunnen gratis advies geven over de installatie van een warmtepomp.<\/p>\n<p>We kunnen zorgen voor service na verkoop, technische assistent.<\/p>\n<p>We kunnen helpen bij de aankoop van andere onderdelen voor warmtepompen of rechtstreeks betrouwbare leveranciers aanbevelen.<\/p>\n<h3>Verzending<\/h3>\n<p>Voor warmtepomp monsters levering, na verpakking met export klasse dikke 5 lagen papier doos, zullen we warmtepompen verpakken met poly hout geval om eventuele schade te voorkomen zoals weergegeven in bijlage.<\/p>\n<p><strong>Er zijn twee manieren om de monsters af te leveren.<\/strong><\/p>\n<p>Bij zeevracht bewaren we het koelmiddel in de warmtepomp.<\/p>\n<p>Bij luchtvracht moet het koelmiddel worden afgetapt vanwege de luchtlijnregeling. Je moet dus het koelmiddel bijvullen als de warmtepomp niet kan starten.<\/p>\n<p>Voor alle producten boven 50kg zetten we het vast op een goed gestructureerde houten of polywood pallet zoals hieronder afgebeeld.<\/p>\n<p><strong>Good\u00a0<\/strong><a href=\"https:\/\/www.china-heatpump.com\/nl\/\"><strong>warmtepomp<\/strong><\/a><strong>\u00a0packing and be careful with every details.<\/strong><\/p>\n<p><img decoding=\"async\" title=\"warmtepompVerpakking\" src=\"\/UploadProductPic\/geothermal-foot.jpg\" alt=\"\" width=\"650\" \/><\/p>\n<p><strong>\u00a0<\/strong><strong>Polywood case packing and Pallet support for safety and no pollution.<\/strong><img decoding=\"async\" title=\"warmtepompVerpakking\" src=\"\/UploadFiles\/heatpumpspacking2.jpg\" alt=\"\" width=\"650\" height=\"487\" \/><\/p>\n<p>Voor levering per container gebruiken we alleen een exportdikke papieren doos met 5 lagen. Na het zorgvuldig laden, nemen we foto's voordat we de containerdeur sluiten om er zeker van te zijn dat alles in orde is.<\/p>\n<p><img decoding=\"async\" title=\"laden van warmtepompen per container\" src=\"\/UploadFiles\/Loading9013-1.jpg\" alt=\"\" width=\"650\" \/><\/p>\n<p>Als het over zee gaat, exporteren we normaal gesproken tegen EXW-, FOB- of CFR-voorwaarden en leveren we alleen goederen af in de zeehaven van bestemming. De klanten moeten de kosten voor hun invoerrechten en kosten dekken. Natuurlijk kunnen klanten gebruik maken van onze expediteur agent om u te helpen om de douane in te klaren.<\/p>\n<p>We kunnen alle benodigde documenten leveren, zoals formulier A, certificaat van oorsprong, vrachtbrief, factuur en paklijst.<\/p>\n<p>Normaal gesproken duurt het ongeveer 30 dagen over zee en een week door de lucht.<\/p>","protected":false},"excerpt":{"rendered":"<p>Direct access to any industrial waste water, domestic waste water, sea water. Titanium Heat exchanger,special water source heat pump for open loop water, can use for directly access to all kinds of water source even working well with sea water. Extrimely easy installation for houses beside river,lake,sea! Heating Cooling \u00a0and domestic hot water functions available<span class=\"excerpt-hellip\"> [...]<\/span><\/p>","protected":false},"author":2,"featured_media":4659,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[56,96,29],"tags":[151],"class_list":["post-900","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-featured-heat-pumps","category-geothermal-water-source-heat-pump","category-heating-knowledge","tag-waste-water-heat-pump"],"_links":{"self":[{"href":"https:\/\/www.china-heatpump.com\/nl\/wp-json\/wp\/v2\/posts\/900","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.china-heatpump.com\/nl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.china-heatpump.com\/nl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.china-heatpump.com\/nl\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.china-heatpump.com\/nl\/wp-json\/wp\/v2\/comments?post=900"}],"version-history":[{"count":2,"href":"https:\/\/www.china-heatpump.com\/nl\/wp-json\/wp\/v2\/posts\/900\/revisions"}],"predecessor-version":[{"id":4661,"href":"https:\/\/www.china-heatpump.com\/nl\/wp-json\/wp\/v2\/posts\/900\/revisions\/4661"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.china-heatpump.com\/nl\/wp-json\/wp\/v2\/media\/4659"}],"wp:attachment":[{"href":"https:\/\/www.china-heatpump.com\/nl\/wp-json\/wp\/v2\/media?parent=900"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.china-heatpump.com\/nl\/wp-json\/wp\/v2\/categories?post=900"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.china-heatpump.com\/nl\/wp-json\/wp\/v2\/tags?post=900"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}