{"id":6201,"date":"2026-05-04T21:58:18","date_gmt":"2026-05-04T13:58:18","guid":{"rendered":"https:\/\/www.china-heatpump.com\/?p=6201"},"modified":"2026-05-04T22:05:30","modified_gmt":"2026-05-04T14:05:30","slug":"kolant-split-evi-inverter-heat-pump-won-ul-certificate-2","status":"publish","type":"post","link":"https:\/\/www.china-heatpump.com\/fr\/kolant-split-evi-inverter-heat-pump-won-ul-certificate-2\/","title":{"rendered":"Kolant Split EVI Inverter pompe \u00e0 chaleur a remport\u00e9 certificat UL"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"6201\" class=\"elementor elementor-6201\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1915f53 e-flex e-con-boxed e-con e-parent\" data-id=\"1915f53\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b37d4b0 elementor-widget elementor-widget-text-editor\" data-id=\"b37d4b0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>La pompe \u00e0 chaleur Kolant 16KW(55000BTU) EVI split Inverter a obtenu le certificat UL pour le march\u00e9 des Etats-Unis et du Canada.<br \/>Les pompes \u00e0 chaleur Kolant EVI split deviennent des pompes \u00e0 chaleur certifi\u00e9es UL et des pompes \u00e0 chaleur europ\u00e9ennes certifi\u00e9es EN14825 et EN813.<\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ee11748 e-flex e-con-boxed e-con e-parent\" data-id=\"ee11748\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-9756c23 e-con-full e-flex e-con e-child\" data-id=\"9756c23\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3bd62e0 elementor-widget elementor-widget-text-editor\" data-id=\"3bd62e0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Kolant EVI split heat pump pass the strict requirement of UL standard and won the UL certificate for Canadian and USA market. Undertake max to 70C outlet water, 21 bar water pressure and all other hard hard testing. Compressor keep running 72 hours.<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-409ba96 elementor-widget elementor-widget-image\" data-id=\"409ba96\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"848\" src=\"https:\/\/www.china-heatpump.com\/wp-content\/uploads\/Kolant-heat-pump-UL-certificates.jpg\" class=\"attachment-full size-full wp-image-3606\" alt=\"\" srcset=\"https:\/\/www.china-heatpump.com\/wp-content\/uploads\/Kolant-heat-pump-UL-certificates.jpg 600w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/Kolant-heat-pump-UL-certificates-212x300.jpg 212w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/Kolant-heat-pump-UL-certificates-8x12.jpg 8w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/Kolant-heat-pump-UL-certificates-103x146.jpg 103w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/Kolant-heat-pump-UL-certificates-35x50.jpg 35w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/Kolant-heat-pump-UL-certificates-53x75.jpg 53w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9ac0c10 e-flex e-con-boxed e-con e-parent\" data-id=\"9ac0c10\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-be2ab35 elementor-widget elementor-widget-text-editor\" data-id=\"be2ab35\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Pompe \u00e0 chaleur Kolant full inverter int\u00e9gr\u00e9e dans un compresseur et un moteur de ventilateur inverter. Conception EVI pour les temp\u00e9ratures ambiantes tr\u00e8s froides. Chauffage, refroidissement et eau chaude sanitaire en une seule solution.<\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-27994e4 e-flex e-con-boxed e-con e-parent\" data-id=\"27994e4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-707ff01 e-con-full e-flex e-con e-child\" data-id=\"707ff01\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-63b6bdf elementor-widget elementor-widget-text-editor\" data-id=\"63b6bdf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>La pompe \u00e0 chaleur Kolant EVI est la meilleure solution pour les zones ultra-froides pour fournir le chauffage, le refroidissement et l'eau chaude sanitaire en une seule solution.<\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bf0e7f8 elementor-widget elementor-widget-text-editor\" data-id=\"bf0e7f8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h4>Forte de Chauffage dans Super Froid la temp\u00e9rature de l&#039;Air.<\/h4>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-18b2610 elementor-widget elementor-widget-text-editor\" data-id=\"18b2610\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Con\u00e7ue sp\u00e9cialement pour la technologie de chauffage \u00e0 temp\u00e9rature ambiante ultra-froide avec un compresseur EVI et deux EEV pour former un syst\u00e8me de jet \u00e0 COP \u00e9lev\u00e9 afin d'augmenter la capacit\u00e9 d'aspiration du compresseur \u00e0 une temp\u00e9rature de l'air tr\u00e8s basse et d'augmenter l'efficacit\u00e9 et les performances de chauffage de l'ensemble du syst\u00e8me. Cette technologie permet \u00e0 la pompe \u00e0 chaleur de continuer \u00e0 chauffer normalement sans l'aide d'un chauffage \u00e9lectrique \u00e0 des temp\u00e9ratures ambiantes ultra-froides.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9cf3859 e-con-full e-flex e-con e-child\" data-id=\"9cf3859\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c3ea69e elementor-widget elementor-widget-image\" data-id=\"c3ea69e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.china-heatpump.com\/wp-content\/uploads\/supercoldEVIhp.jpg\" class=\"attachment-large size-large wp-image-4756\" alt=\"\" srcset=\"https:\/\/www.china-heatpump.com\/wp-content\/uploads\/supercoldEVIhp.jpg 600w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/supercoldEVIhp-300x300.jpg 300w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/supercoldEVIhp-12x12.jpg 12w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/supercoldEVIhp-146x146.jpg 146w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/supercoldEVIhp-50x50.jpg 50w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/supercoldEVIhp-75x75.jpg 75w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/supercoldEVIhp-85x85.jpg 85w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/supercoldEVIhp-80x80.jpg 80w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ecb649d e-flex e-con-boxed e-con e-parent\" data-id=\"ecb649d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-a075b86 e-con-full e-flex e-con e-child\" data-id=\"a075b86\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8cb3999 elementor-widget elementor-widget-image\" data-id=\"8cb3999\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"435\" height=\"829\" src=\"https:\/\/www.china-heatpump.com\/wp-content\/uploads\/Energylabel15K.jpg\" class=\"attachment-large size-large wp-image-3169\" alt=\"\" srcset=\"https:\/\/www.china-heatpump.com\/wp-content\/uploads\/Energylabel15K.jpg 435w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/Energylabel15K-157x300.jpg 157w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/Energylabel15K-6x12.jpg 6w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/Energylabel15K-77x146.jpg 77w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/Energylabel15K-26x50.jpg 26w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/Energylabel15K-39x75.jpg 39w\" sizes=\"(max-width: 435px) 100vw, 435px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e825af4 e-con-full e-flex e-con e-child\" data-id=\"e825af4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-655625d elementor-widget elementor-widget-text-editor\" data-id=\"655625d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h4>Label \u00e9nerg\u00e9tique A++<\/h4><hr class=\"no_line\" \/><p>Kolant&#8217;s R32 refrigerant heat pump has achieved the prestigious A+++ energy class, a testament to its exceptional efficiency under the rigorous European standards EU813 and EN14825. This top-tier rating underscores the product&#8217;s ability to deliver superior performance while minimizing energy consumption, aligning perfectly with Europe&#8217;s stringent environmental and energy efficiency goals.\u200b<br \/>R32 refrigerant, known for its lower global warming potential compared to many traditional alternatives, is a key component in Kolant&#8217;s commitment to sustainability. When paired with the heat pump&#8217;s advanced engineering, it creates a system that excels in converting energy into usable heat, even in varying climatic conditions. The compliance with EU813, which sets requirements for the energy performance of space heating and cooling equipment, and EN14825, specifying testing methods for air-source heat pumps, ensures that every unit meets consistent, high-quality standards.\u200b<br \/>For European consumers and businesses, the A+++ rating translates to tangible benefits. It means significantly reduced energy bills over the product&#8217;s lifespan, as the heat pump operates with maximum efficiency. Additionally, it contributes to lowering carbon footprints, supporting both individual and collective efforts to combat climate change.\u200b<br \/>Kolant&#8217;s achievement in securing this elite energy class reinforces its position as a leader in sustainable heating solutions. By combining innovative refrigerant technology with adherence to strict European standards, the R32 heat pump not only meets but exceeds expectations, offering a reliable, efficient, and eco-friendly choice for modern heating needs.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-50a5bd1 e-flex e-con-boxed e-con e-parent\" data-id=\"50a5bd1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bd9e96c elementor-widget elementor-widget-heading\" data-id=\"bd9e96c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Avantage de la technologie de chauffage Kolant EVl<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-269a687 e-flex e-con-boxed e-con e-parent\" data-id=\"269a687\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3dcde48 elementor-widget elementor-widget-text-editor\" data-id=\"3dcde48\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"column mcb-column mcb-item-06a603bce one column_column\"><div class=\"column_attr clearfix\"><p>There is no doubt that air source heat pumps can make great economic and environmental benefits if they are properly used. However, as a matter of fact, most air source heat pumps work with very poor efficiency or even can not work when the environment temperature is lower than -10\u2103. It also extend the compressor working ambient temp to -35C. The EVl (enhanced vapor injection) heating technology is an innovation in the compressor and the refrigerant circulation. By this technology the permitted operating range of a heat pump is extended to a much lower air temperature region, and the heating performance under low environment temperature is greatly improved.<\/p><\/div><\/div><div class=\"column mcb-column mcb-item-krx1ar2u2 one column_column\"><div class=\"column_attr clearfix\"><hr class=\"no_line\" \/><p>Reliable running under environment temperature to -35C air temp Getting much higher water temperature during low environment temperature Heating capacity up to 40% higher than normal heat pumps COP 10%-20% higher during low environment temperature.<\/p><\/div><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5fc1768 e-flex e-con-boxed e-con e-parent\" data-id=\"5fc1768\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-753ca04 elementor-widget__width-initial elementor-position-top elementor-widget elementor-widget-image-box\" data-id=\"753ca04\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-image-box-wrapper\"><figure class=\"elementor-image-box-img\"><img loading=\"lazy\" decoding=\"async\" width=\"839\" height=\"658\" src=\"https:\/\/www.china-heatpump.com\/wp-content\/uploads\/Compressor.png\" class=\"attachment-full size-full wp-image-3166\" alt=\"\" srcset=\"https:\/\/www.china-heatpump.com\/wp-content\/uploads\/Compressor.png 839w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/Compressor-383x300.png 383w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/Compressor-16x12.png 16w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/Compressor-186x146.png 186w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/Compressor-50x39.png 50w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/Compressor-96x75.png 96w\" sizes=\"(max-width: 839px) 100vw, 839px\" \/><\/figure><div class=\"elementor-image-box-content\"><h3 class=\"elementor-image-box-title\">Compresseur \u00e0 inverseur EVl DC de marque internationale<\/h3><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8ed4d90 elementor-widget__width-initial elementor-position-top elementor-widget elementor-widget-image-box\" data-id=\"8ed4d90\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-image-box-wrapper\"><figure class=\"elementor-image-box-img\"><img loading=\"lazy\" decoding=\"async\" width=\"803\" height=\"646\" src=\"https:\/\/www.china-heatpump.com\/wp-content\/uploads\/WaterElectricitySep.png\" class=\"attachment-full size-full wp-image-3168\" alt=\"\" srcset=\"https:\/\/www.china-heatpump.com\/wp-content\/uploads\/WaterElectricitySep.png 803w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/WaterElectricitySep-373x300.png 373w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/WaterElectricitySep-16x12.png 16w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/WaterElectricitySep-181x146.png 181w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/WaterElectricitySep-50x40.png 50w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/WaterElectricitySep-93x75.png 93w\" sizes=\"(max-width: 803px) 100vw, 803px\" \/><\/figure><div class=\"elementor-image-box-content\"><h3 class=\"elementor-image-box-title\">Pas de fuite d'\u00e9lectricit\u00e9, pas de fuite de r\u00e9frig\u00e9rant<\/h3><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4c010cf elementor-position-top elementor-widget elementor-widget-image-box\" data-id=\"4c010cf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-image-box-wrapper\"><figure class=\"elementor-image-box-img\"><img loading=\"lazy\" decoding=\"async\" width=\"773\" height=\"640\" src=\"https:\/\/www.china-heatpump.com\/wp-content\/uploads\/HeatingCoolingDHW.png\" class=\"attachment-full size-full wp-image-3167\" alt=\"\" srcset=\"https:\/\/www.china-heatpump.com\/wp-content\/uploads\/HeatingCoolingDHW.png 773w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/HeatingCoolingDHW-362x300.png 362w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/HeatingCoolingDHW-14x12.png 14w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/HeatingCoolingDHW-176x146.png 176w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/HeatingCoolingDHW-50x41.png 50w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/HeatingCoolingDHW-91x75.png 91w\" sizes=\"(max-width: 773px) 100vw, 773px\" \/><\/figure><div class=\"elementor-image-box-content\"><h3 class=\"elementor-image-box-title\">Chauffage, refroidissement et ECS en une seule solution pour des temp\u00e9ratures ambiantes tr\u00e8s basses.<\/h3><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4b0aa1c e-flex e-con-boxed e-con e-parent\" data-id=\"4b0aa1c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bc27746 elementor-widget elementor-widget-heading\" data-id=\"bc27746\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Les pompes \u00e0 chaleur Kolant sont con\u00e7ues avec une s\u00e9rie de d\u00e9tails de conception et de production uniques qui fonctionnent en harmonie pour r\u00e9pondre \u00e0 trois priorit\u00e9s essentielles :<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-037f4cf e-flex e-con-boxed e-con e-parent\" data-id=\"037f4cf\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-15c0644 elementor-widget elementor-widget-text-editor\" data-id=\"15c0644\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Preventing leakage, minimizing noise, and maximizing performance. Each feature is meticulously crafted to set the product apart in the competitive heat pump market, delivering exceptional value to users.<br>First and foremost, the full insulation design is a testament to Kolant&#8217;s commitment to efficiency. Unlike conventional heat pumps from other factories, which often suffer from energy loss due to inadequate insulation, Kolant&#8217;s system employs a comprehensive insulation solution that covers all key components. This not only reduces heat dissipation during operation but also ensures that the system maintains optimal working temperatures even in extreme environments. The result is a remarkable 2% increase in COP (Coefficient of Performance) compared to industry counterparts. This seemingly modest percentage translates to significant long-term energy savings, making Kolant heat pumps a more cost-effective choice for both residential and commercial applications.<br>Another standout feature is the integration of two electronic expansion valves, a design choice that revolutionizes EVI (Enhanced Vapor Injection) control. Traditional heat pumps rely on thermal expansion valves, which are prone to imprecise regulation due to their dependence on temperature changes. In contrast, Kolant&#8217;s dual electronic expansion valves use advanced sensors and microprocessors to adjust refrigerant flow with pinpoint accuracy. This precise control over the EVI process ensures that the heat pump operates at peak efficiency across a wide range of operating conditions, from mild to extreme temperatures. The impact is substantial: a 15% increase in COP compared to systems using thermal expansion valves. This boost in efficiency not only reduces energy consumption but also enhances the heat pump&#8217;s ability to deliver consistent performance when it matters most.<\/p>\n<p><span style=\"font-family: &quot;Nunito Sans&quot;, Arial, Tahoma, sans-serif; font-size: 14px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400;\">Kolant&#8217;s smart pre-design anti-vibration kits are a key factor in preventing leakage and ensuring long-term reliability. These kits are far more sophisticated than the standard anti-vibration solutions commonly displayed in the market. They are engineered to absorb and dampen vibrations at multiple points within the heat pump, from the compressor to the refrigerant lines. By minimizing vibration, the kits reduce stress on connections and seals, which are often the primary sources of leakage in heat pumps. This proactive approach to vibration control not only prevents costly and inconvenient leaks but also contributes to the heat pump&#8217;s ability to operate without the need for frequent aftersales service. Users can enjoy peace of mind knowing that their Kolant heat pump is designed to be virtually maintenance-free, with a focus on durability and longevity.<\/span><br style=\"box-sizing: inherit;\"><span style=\"font-family: &quot;Nunito Sans&quot;, Arial, Tahoma, sans-serif; font-size: 14px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400;\">Last but not least, the combination of a flying bird wing fan and an EC (Electronically Commutated) fan motor is a masterstroke in noise reduction. The flying bird wing fan is inspired by nature, with a blade design that minimizes air turbulence and reduces noise generation. This aerodynamic design allows the fan to move air efficiently while producing less sound. Complementing this, the EC fan motor operates with greater precision and lower energy consumption than traditional motors. It adjusts its speed dynamically based on the heat pump&#8217;s cooling needs, further reducing noise levels during operation. Together, these components create a significantly quieter working environment, making Kolant heat pumps ideal for use in residential areas, offices, and other spaces where noise pollution is a concern.<\/span><br><\/p><p><span style=\"font-family: &quot;Nunito Sans&quot;, Arial, Tahoma, sans-serif; font-size: 14px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400;\">En r\u00e9sum\u00e9, les pompes \u00e0 chaleur Kolant se distinguent sur le march\u00e9 par leur conception r\u00e9fl\u00e9chie et innovante. Qu'il s'agisse de l'isolation compl\u00e8te qui am\u00e9liore l'efficacit\u00e9, du double d\u00e9tendeur \u00e9lectronique, des kits anti-vibrations intelligents qui pr\u00e9viennent les fuites ou du syst\u00e8me de ventilation qui r\u00e9duit le bruit, chaque d\u00e9tail est con\u00e7u pour offrir des performances, une fiabilit\u00e9 et un confort d'utilisation sup\u00e9rieurs. Ces caract\u00e9ristiques distinguent Kolant de ses concurrents et font de ses pompes \u00e0 chaleur un choix judicieux pour tous ceux qui recherchent une solution de chauffage de haute qualit\u00e9, efficace et n\u00e9cessitant peu d'entretien.<\/span><span style=\"font-family: &quot;Nunito Sans&quot;, Arial, Tahoma, sans-serif; font-size: 14px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400;\"><br><\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-662c42e e-flex e-con-boxed e-con e-parent\" data-id=\"662c42e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-847ed16 e-con-full e-flex e-con e-child\" data-id=\"847ed16\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6544e16 elementor-widget elementor-widget-image\" data-id=\"6544e16\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"480\" height=\"480\" src=\"https:\/\/www.china-heatpump.com\/wp-content\/uploads\/FullInsulation.jpg\" class=\"attachment-large size-large wp-image-3999\" alt=\"\" srcset=\"https:\/\/www.china-heatpump.com\/wp-content\/uploads\/FullInsulation.jpg 480w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/FullInsulation-300x300.jpg 300w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/FullInsulation-12x12.jpg 12w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/FullInsulation-146x146.jpg 146w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/FullInsulation-50x50.jpg 50w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/FullInsulation-75x75.jpg 75w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/FullInsulation-85x85.jpg 85w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/FullInsulation-80x80.jpg 80w\" sizes=\"(max-width: 480px) 100vw, 480px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b6ab76a e-con-full e-flex e-con e-child\" data-id=\"b6ab76a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cd07ff1 elementor-widget elementor-widget-image\" data-id=\"cd07ff1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"452\" height=\"452\" src=\"https:\/\/www.china-heatpump.com\/wp-content\/uploads\/EVIHeatpump2EEV.jpg\" class=\"attachment-large size-large wp-image-4000\" alt=\"\" srcset=\"https:\/\/www.china-heatpump.com\/wp-content\/uploads\/EVIHeatpump2EEV.jpg 452w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/EVIHeatpump2EEV-300x300.jpg 300w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/EVIHeatpump2EEV-12x12.jpg 12w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/EVIHeatpump2EEV-146x146.jpg 146w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/EVIHeatpump2EEV-50x50.jpg 50w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/EVIHeatpump2EEV-75x75.jpg 75w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/EVIHeatpump2EEV-85x85.jpg 85w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/EVIHeatpump2EEV-80x80.jpg 80w\" sizes=\"(max-width: 452px) 100vw, 452px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0b5a887 e-con-full e-flex e-con e-child\" data-id=\"0b5a887\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bd073b8 elementor-widget elementor-widget-image\" data-id=\"bd073b8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"480\" height=\"480\" src=\"https:\/\/www.china-heatpump.com\/wp-content\/uploads\/AntivibrationDesign3.jpg\" class=\"attachment-large size-large wp-image-4001\" alt=\"\" srcset=\"https:\/\/www.china-heatpump.com\/wp-content\/uploads\/AntivibrationDesign3.jpg 480w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/AntivibrationDesign3-300x300.jpg 300w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/AntivibrationDesign3-12x12.jpg 12w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/AntivibrationDesign3-146x146.jpg 146w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/AntivibrationDesign3-50x50.jpg 50w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/AntivibrationDesign3-75x75.jpg 75w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/AntivibrationDesign3-85x85.jpg 85w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/AntivibrationDesign3-80x80.jpg 80w\" sizes=\"(max-width: 480px) 100vw, 480px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5ca05bc e-con-full e-flex e-con e-child\" data-id=\"5ca05bc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f004185 elementor-widget elementor-widget-image\" data-id=\"f004185\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"795\" height=\"793\" src=\"https:\/\/www.china-heatpump.com\/wp-content\/uploads\/FlyingbirdwingFan.jpg\" class=\"attachment-large size-large wp-image-4002\" alt=\"\" srcset=\"https:\/\/www.china-heatpump.com\/wp-content\/uploads\/FlyingbirdwingFan.jpg 795w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/FlyingbirdwingFan-301x300.jpg 301w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/FlyingbirdwingFan-12x12.jpg 12w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/FlyingbirdwingFan-146x146.jpg 146w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/FlyingbirdwingFan-50x50.jpg 50w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/FlyingbirdwingFan-75x75.jpg 75w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/FlyingbirdwingFan-85x85.jpg 85w, https:\/\/www.china-heatpump.com\/wp-content\/uploads\/FlyingbirdwingFan-80x80.jpg 80w\" sizes=\"(max-width: 795px) 100vw, 795px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Kolant 16KW(55000BTU) EVI split Inverter Heat Pump won UL certificate for USA and Canada market Kolant EVI split heat pump become UL certified heat pumps and European EN14825 and EN813 certified heat pumps Kolant EVI split heat pump pass the strict requirement of UL standard and won the UL certificate for Canadian and USA market.<span class=\"excerpt-hellip\"> [...]<\/span><\/p>","protected":false},"author":2,"featured_media":4749,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[29,51],"tags":[284,327,328],"class_list":["post-6201","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-heating-knowledge","category-split-evi-inverter-heat-pump","tag-evi-heat-pump","tag-evi-split-heat-pump","tag-inverter-evi-heat-pump"],"_links":{"self":[{"href":"https:\/\/www.china-heatpump.com\/fr\/wp-json\/wp\/v2\/posts\/6201","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.china-heatpump.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.china-heatpump.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.china-heatpump.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.china-heatpump.com\/fr\/wp-json\/wp\/v2\/comments?post=6201"}],"version-history":[{"count":4,"href":"https:\/\/www.china-heatpump.com\/fr\/wp-json\/wp\/v2\/posts\/6201\/revisions"}],"predecessor-version":[{"id":6205,"href":"https:\/\/www.china-heatpump.com\/fr\/wp-json\/wp\/v2\/posts\/6201\/revisions\/6205"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.china-heatpump.com\/fr\/wp-json\/wp\/v2\/media\/4749"}],"wp:attachment":[{"href":"https:\/\/www.china-heatpump.com\/fr\/wp-json\/wp\/v2\/media?parent=6201"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.china-heatpump.com\/fr\/wp-json\/wp\/v2\/categories?post=6201"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.china-heatpump.com\/fr\/wp-json\/wp\/v2\/tags?post=6201"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}