{"id":837,"date":"2011-09-15T16:31:00","date_gmt":"2011-09-15T08:31:00","guid":{"rendered":"\/?p=837"},"modified":"2025-12-03T16:33:37","modified_gmt":"2025-12-03T08:33:37","slug":"low-ambient-temp-split-heat-pump-to-replace-gas-boiler","status":"publish","type":"post","link":"https:\/\/www.china-heatpump.com\/es\/low-ambient-temp-split-heat-pump-to-replace-gas-boiler\/","title":{"rendered":"Bomba de calor split de baja temperatura ambiente para sustituir caldera de gas-9,11,15,18,23,30,45KW"},"content":{"rendered":"<p><strong>Minus -35 \u00baC working heating-Kolant split heat pump<\/strong><\/p>\n<p><strong>Best replacement for old gas boiler with Kolant split\u00a0<\/strong><a href=\"https:\/\/www.china-heatpump.com\/es\/\"><strong>bomba de calor<\/strong><\/a><strong>.<\/strong><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone\" title=\"replace gas boiler with heat pump\" src=\"https:\/\/www.china-heatpump.com\/wp-content\/uploads\/EVI-replaceGasboiler1.jpg\" alt=\"replace gas boiler with heat pump\" width=\"650\" height=\"487\" \/><\/p>\n<p><strong>Heating + Cooling + Domestic hot water in one solution. Similar function as popular split <\/strong><a href=\"https:\/\/www.china-heatpump.com\/es\/\"><strong>bomba de calor<\/strong><\/a><strong>.<\/strong><br \/>\n<strong>Can be working heating in super cold weather.<\/strong><br \/>\n<img decoding=\"async\" class=\"bdpimg\" src=\"\/UploadFiles\/Finland_4956S.jpg\" alt=\"Low ambient temp heat pump heating in snowing weather\" width=\"500\" \/><\/p>\n<p><strong>Products characters<\/strong><\/p>\n<p>1. It can provide air heating, air cooling and domestic hot water in one solution, similar function as LG Therma V and Daikin Altherma split heat pump.<br \/>\n2. It can utilize the existing water tank, radiator and other heating system and is idea equipment for home upgrading to energy saving house.<br \/>\n3. Built inside solar connection program enable solar for hot water and air heating together.<br \/>\n4. Excellent auto defrost for keeping heating during -20 centigrade.<br \/>\neven in electric power off accident, it still can keep no freeze for several days.<br \/>\nSpecial patent outdoor design to prevent the ice building during winter heating.<br \/>\nBuilt in crankcase heater to protect compressor during winter.<br \/>\n5. One water tank with expansion tank and backup electric heaters, other hydraulic components built inside<br \/>\n6. Timers on\/off for you to choose the lowest electricity price period for operation to save your bill the most.<br \/>\n7. Parts are always choosen with the top brand in the world to assure quality, reliability and save maintenance cost.<\/p>\n<p><strong>Reliable Quality for saving maintenance cost:<br \/>\n<\/strong>\u00a0 Our parts are always choosend with the top brand in the world<br \/>\nHeat exchanger: SU316 stainless plate heat exchanger.<br \/>\nThe compressor: Daikin, Hitachi,Toshiba,Sanyo brand<br \/>\nV\u00e1lvula de expansi\u00f3n t\u00e9rmica: <strong>Emerson<\/strong> marca<br \/>\nOptional water pump: <strong>Wilo<\/strong> brand from Germany<br \/>\nV\u00e1lvula de cuatro v\u00edas: <strong>Saginomiya <\/strong>marca de Jap\u00f3n<br \/>\nEstas piezas permiten que nuestra bomba de calor sea un producto sin problemas.<\/p>\n<p><strong>Kolant EVI split inverter heat pump specification:<\/strong><\/p>\n<table width=\"677\">\n<tbody>\n<tr>\n<td width=\"81\">Modelos<\/td>\n<td width=\"81\">Temperatura del aire\/temperatura del agua de salida<\/td>\n<td width=\"71\">RJ85\/N8-BPEEVI<\/td>\n<td width=\"35\">COP<\/td>\n<td width=\"68\">RJ-110H\/N8-BPE<\/td>\n<td width=\"34\">COP<\/td>\n<td width=\"75\">RJ-150H\/SN8-BPEEVI<\/td>\n<td width=\"36\">COP<\/td>\n<td width=\"67\">RJ-180H\/SN8-BPEEVI<\/td>\n<td width=\"30\">COP<\/td>\n<td width=\"68\">RJ-230H\/SN8-BPEEVI<\/td>\n<td width=\"31\">COP<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"7\" width=\"81\">Heating capacity\/Power input (KW)<\/td>\n<td>a A20\/W35\u00b0C<\/td>\n<td>10.6\/1.89<\/td>\n<td width=\"35\">5.61<\/td>\n<td width=\"68\">14.42\/2.88<\/td>\n<td width=\"34\">5.01<\/td>\n<td>21.1\/3.89<\/td>\n<td width=\"36\">5.42<\/td>\n<td>22.8\/4.4<\/td>\n<td width=\"30\">5.18<\/td>\n<td>29.5\/6.01<\/td>\n<td width=\"31\">4.91<\/td>\n<\/tr>\n<tr>\n<td>a A7\/W35\u00b0C<\/td>\n<td>8.59\/1.87<\/td>\n<td width=\"35\">4.59<\/td>\n<td width=\"68\">10.6\/2.55<\/td>\n<td width=\"34\">4.16<\/td>\n<td>14.7\/3.31<\/td>\n<td width=\"36\">4.44<\/td>\n<td>18.8\/4.4<\/td>\n<td width=\"30\">4.27<\/td>\n<td>23.1\/5.34<\/td>\n<td width=\"31\">4.33<\/td>\n<\/tr>\n<tr>\n<td>a A7\/W45\u00b0C<\/td>\n<td>7.91\/2.23<\/td>\n<td width=\"35\">3.55<\/td>\n<td width=\"68\">9.97\/3.14<\/td>\n<td width=\"34\">3.18<\/td>\n<td>13.5\/4.1<\/td>\n<td width=\"36\">3.29<\/td>\n<td>17.8\/5.24<\/td>\n<td width=\"30\">3.4<\/td>\n<td>22.6\/6.11<\/td>\n<td width=\"31\">3.7<\/td>\n<\/tr>\n<tr>\n<td>a A2\/W35\u00b0C<\/td>\n<td>7.65\/1.81<\/td>\n<td width=\"35\">4.23<\/td>\n<td width=\"68\">9.54\/2.49<\/td>\n<td width=\"34\">3.83<\/td>\n<td>13.08\/3.21<\/td>\n<td width=\"36\">4.07<\/td>\n<td>16.92\/4.31<\/td>\n<td width=\"30\">3.93<\/td>\n<td>20.29\/5.38<\/td>\n<td width=\"31\">3.77<\/td>\n<\/tr>\n<tr>\n<td>a A2\/W45\u00b0C<\/td>\n<td>7.04\/2.15<\/td>\n<td width=\"35\">3.27<\/td>\n<td width=\"68\">8.97\/3.06<\/td>\n<td width=\"34\">2.93<\/td>\n<td>12.02\/3.97<\/td>\n<td width=\"36\">3.03<\/td>\n<td>16\/5.12<\/td>\n<td width=\"30\">3.13<\/td>\n<td>18.7\/6.4<\/td>\n<td width=\"31\">2.92<\/td>\n<\/tr>\n<tr>\n<td>a A-12\/W41\u00b0C<\/td>\n<td>5.9\/2.45<\/td>\n<td width=\"35\">2.41<\/td>\n<td width=\"68\">6.3\/2.7<\/td>\n<td width=\"34\">2.33<\/td>\n<td>10.2\/4.35<\/td>\n<td width=\"36\">2.34<\/td>\n<td>11.6\/5.04<\/td>\n<td width=\"30\">2.3<\/td>\n<td>14.7\/5.88<\/td>\n<td width=\"31\">2.5<\/td>\n<\/tr>\n<tr>\n<td>a A-20\/W41\u00b0C<\/td>\n<td>5.4\/2.56<\/td>\n<td>2.11<\/td>\n<td>5.61\/2.72<\/td>\n<td width=\"34\">2.06<\/td>\n<td>8.9\/4.23<\/td>\n<td width=\"36\">2.1<\/td>\n<td>10.5\/4.97<\/td>\n<td width=\"30\">2.11<\/td>\n<td>13.7\/5.78<\/td>\n<td width=\"31\">2.37<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"81\">Cooling Capacity\/Power input(KW)<\/td>\n<td>a A35\/ W18\u00baC<\/td>\n<td>9.2\/2.7<\/td>\n<td width=\"35\">3.41<\/td>\n<td width=\"68\">11\/3.3<\/td>\n<td width=\"34\">3.33<\/td>\n<td>13.9\/4.2<\/td>\n<td width=\"36\">3.31<\/td>\n<td>15.6\/4.8<\/td>\n<td width=\"30\">3.25<\/td>\n<td>20.1\/6.2<\/td>\n<td width=\"31\">3.24<\/td>\n<\/tr>\n<tr>\n<td>a A35\/W7\u00baC<\/td>\n<td>7.2\/2.73<\/td>\n<td width=\"35\">2.64<\/td>\n<td width=\"68\">8.6\/3.4<\/td>\n<td width=\"34\">2.53<\/td>\n<td>9.8\/3.77<\/td>\n<td width=\"36\">2.6<\/td>\n<td>10.5\/4.2<\/td>\n<td width=\"30\">2.5<\/td>\n<td>13.5\/5.09<\/td>\n<td width=\"31\">2.65<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Corriente m\u00e1x. (A)<\/td>\n<td>18<\/td>\n<td><\/td>\n<td>19<\/td>\n<td><\/td>\n<td>28<\/td>\n<td><\/td>\n<td>14.3<\/td>\n<td><\/td>\n<td>18.1<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Suministro el\u00e9ctrico<\/td>\n<td colspan=\"4\">230V\/50~60HZ<\/td>\n<td colspan=\"2\">400V\/50~60HZ<\/td>\n<td colspan=\"4\">400V\/50~60HZ<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Max.Outlet water temperature (\u00a0oC)<\/td>\n<td colspan=\"10\">60<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Rango de temperatura de funcionamiento (oC)<\/td>\n<td colspan=\"10\">-30 ~ 43<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" width=\"81\">Circuito refrigerante<\/td>\n<td>Refrigerante<\/td>\n<td colspan=\"10\">R32<\/td>\n<\/tr>\n<tr>\n<td width=\"81\">DC Inverter compressor<\/td>\n<td>MITSUBISHI<\/td>\n<td><\/td>\n<td>MITSUBISHI<\/td>\n<td><\/td>\n<td>MITSUBISHI<\/td>\n<td><\/td>\n<td>MITSUBISHI<\/td>\n<td><\/td>\n<td>MITSUBISHI<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td width=\"81\">Intercambiador de calor<\/td>\n<td colspan=\"8\">Aleta de cobre y aluminio hidr\u00f3filo<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Caudal de aire (m3\/h)<\/td>\n<td>2400<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td>5800<\/td>\n<td><\/td>\n<td>6000<\/td>\n<td><\/td>\n<td>7000<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" width=\"81\">Circuito de agua<\/td>\n<td>Intercambiador de calor<\/td>\n<td colspan=\"8\" width=\"416\">Intercambiador de calor de tubo en carcasa de alto rendimiento<\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Tuber\u00eda de entrada\/salida<\/td>\n<td>DN25(G1\u2033)<\/td>\n<td><\/td>\n<td>DN25(G1\u2033)<\/td>\n<td><\/td>\n<td>DN25(G1\u2033)<\/td>\n<td><\/td>\n<td>DN25(G1\u2033)<\/td>\n<td><\/td>\n<td>DN25(G1\u2033)<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Caudal de agua (m3\/h)<\/td>\n<td>\u22651.5<\/td>\n<td><\/td>\n<td>\u22651.8<\/td>\n<td><\/td>\n<td>\u22652.5<\/td>\n<td><\/td>\n<td>\u22653<\/td>\n<td><\/td>\n<td>\u22653.9<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>presi\u00f3n permitida<\/td>\n<td colspan=\"10\">\u22640,8MPa<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Dimensiones de la unidad AnxAlxPr (mm)<\/td>\n<td>960*820*380<\/td>\n<td><\/td>\n<td>960*820*380<\/td>\n<td><\/td>\n<td>960*1270*380<\/td>\n<td><\/td>\n<td>960*1270*380<\/td>\n<td><\/td>\n<td>1030*1340*390<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Dimensiones del paquete AnxAlxPr (mm)<\/td>\n<td>1040*940*502<\/td>\n<td><\/td>\n<td>1040*940*502<\/td>\n<td><\/td>\n<td>1040*1390*502<\/td>\n<td><\/td>\n<td>1040*1390*502<\/td>\n<td><\/td>\n<td>1115*1510*510<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Net weight\u00a0\u00a0\u00a0\u00a0 (Kg)<\/td>\n<td>68<\/td>\n<td><\/td>\n<td>68<\/td>\n<td><\/td>\n<td>108<\/td>\n<td><\/td>\n<td>108<\/td>\n<td><\/td>\n<td>128<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Gross weight\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 (Kg)<\/td>\n<td>85<\/td>\n<td><\/td>\n<td>85<\/td>\n<td><\/td>\n<td>125<\/td>\n<td><\/td>\n<td>125<\/td>\n<td><\/td>\n<td>145<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Noise level\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 dB(A)<\/td>\n<td>56<\/td>\n<td><\/td>\n<td>56<\/td>\n<td><\/td>\n<td>59<\/td>\n<td><\/td>\n<td>59<\/td>\n<td><\/td>\n<td>60<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Loading quantity for 20\u2019\/40\u2032<\/td>\n<td>44\/88<\/td>\n<td><\/td>\n<td>44\/88<\/td>\n<td><\/td>\n<td>22\/44<\/td>\n<td><\/td>\n<td>22\/44<\/td>\n<td><\/td>\n<td>22\/44<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"color: revert; font-size: 25px;\">Two Year Warranty !<\/span><\/p>\n<p><span style=\"font-family: arial;\"><span style=\"font-family: arial;\">We provide 1% free spareparts with containered order and 2 year warranty of main parts for factory fault since shipment arrival.<\/span><br \/>\nWe will send the spare parts by courrier method after confirm it is due to factory fault.<br \/>\nWe don&#8217;t cover the cost for failure from shipment, wrong installation and incorrect usage. Of course we can provide parts by customer&#8217;s cost after warranty period.<\/span><\/p>\n<h3>Atenci\u00f3n al cliente<\/h3>\n<p><span style=\"font-family: arial;\">Le asesoramos gratuitamente sobre la instalaci\u00f3n de una bomba de calor. <\/span><\/p>\n<p><span style=\"font-family: arial;\">We can provide after sales service, technical assistant. <\/span><span style=\"font-family: arial;\"><br \/>\nPodemos ayudarle a adquirir otras piezas relacionadas con las bombas de calor o recomendarle directamente proveedores fiables.<\/span><\/p>\n<h3>Env\u00edo<\/h3>\n<p><span style=\"font-family: arial;\">For heat pump samples delivery, after packing with export class thick 5 layers paper box, we will pack heat pumps with poly wood case to avoid any damage as shown attached.<\/span><\/p>\n<p><span style=\"font-family: arial;\"><strong>There are two ways to delivery the samples.<br \/>\n<\/strong>For sea freight, we will keep the refrigerant inside of the heat pump.<br \/>\nFor air freight cargo, due to the air line regulation, we need to drain out the refrigerant. So you need to charge the refrigerant if you find the heat pump cannot start.<br \/>\nFor all products above 50kg, we will fix it on a good structured wood or polywood pallet as shown below.<\/p>\n<p><\/span><\/p>\n<p><span style=\"font-family: arial;\">For Container delivery, we use only export thick 5 layer paper box. After carefully loading, we will take pictures before close the container door to assure everything is ok.<br \/>\n<img decoding=\"async\" title=\"heatpump loading by container\" src=\"\/UploadFiles\/Loading9013-1.jpg\" alt=\"\" width=\"650\" \/><\/span><\/p>\n<p>If by sea, normally we export at EXW, FOB or CFR terms, we only delivery goods to the destination sea port. The customers need to cover cost for their import duty and cost. Of course the customers can use our forwarder agent to help you to clear the customs.<br \/>\nWe can provide all necessary document such as Form A, certificate of origin, Bill of lading, Invoice and packing list.<\/p>\n<p>Normally it will take about 30 days by sea and one week by air.<\/p>","protected":false},"excerpt":{"rendered":"<p>Calefacci\u00f3n con funcionamiento a menos -35 \u00baC-Bomba de calor split Kolant El mejor sustituto para la vieja caldera de gas con la bomba de calor split Kolant. Calefacci\u00f3n + [...]<\/p>","protected":false},"author":2,"featured_media":4765,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[56,51],"tags":[102,28,60,103,55],"faqcat":[],"class_list":["post-837","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-featured-heat-pumps","category-split-evi-inverter-heat-pump","tag-air-source-heat-pump","tag-heat-pump","tag-low-temperature-heat-pump","tag-replace-gas-boiler","tag-split-heat-pump"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.china-heatpump.com\/es\/wp-json\/wp\/v2\/posts\/837","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.china-heatpump.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.china-heatpump.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.china-heatpump.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.china-heatpump.com\/es\/wp-json\/wp\/v2\/comments?post=837"}],"version-history":[{"count":0,"href":"https:\/\/www.china-heatpump.com\/es\/wp-json\/wp\/v2\/posts\/837\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.china-heatpump.com\/es\/wp-json\/wp\/v2\/media\/4765"}],"wp:attachment":[{"href":"https:\/\/www.china-heatpump.com\/es\/wp-json\/wp\/v2\/media?parent=837"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.china-heatpump.com\/es\/wp-json\/wp\/v2\/categories?post=837"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.china-heatpump.com\/es\/wp-json\/wp\/v2\/tags?post=837"},{"taxonomy":"faqcat","embeddable":true,"href":"https:\/\/www.china-heatpump.com\/es\/wp-json\/wp\/v2\/faqcat?post=837"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}