{"id":1696,"date":"2014-09-05T17:15:43","date_gmt":"2014-09-05T09:15:43","guid":{"rendered":"\/?p=1166"},"modified":"2025-04-07T15:00:32","modified_gmt":"2025-04-07T07:00:32","slug":"dc-inverter-heat-pump-9kw-with-highest-cop","status":"publish","type":"post","link":"https:\/\/www.china-heatpump.com\/de\/dc-inverter-heat-pump-9kw-with-highest-cop\/","title":{"rendered":"DC-Inverter-W\u00e4rmepumpe 9KW mit h\u00f6chstem COP"},"content":{"rendered":"<p><strong><img decoding=\"async\" alt=\"\" src=\"\/UploadProductPic\/DC-inverter-air-source-heatpump.jpg\" \/><\/strong><\/p>\n<p><strong style=\"line-height: 1.5em;\">COP 5,97 f\u00fcr 9KW DC-Inverter-Luft-W\u00e4rmepumpe mit Heiz- und K\u00fchlfunktion und Warmwasserbereitung, R410a,\u00a0<\/strong><\/p>\n<p><strong>Mit fortschrittlichster europ\u00e4ischer Technologie, die auch bei Minus 25\u00baC funktioniert<\/strong><\/p>\n<p>viel h\u00f6herer Wirkungsgrad als normale Luftw\u00e4rmepumpe.<\/p>\n<p><strong>Wichtigsten Zeichen:<\/strong><\/p>\n<p>1. Viel h\u00f6herer COP als normale DC-Inverter-W\u00e4rmepumpe<\/p>\n<p>2.  Die Installation ist einfach und flexibel...<\/p>\n<p>3.  Kann mit Solar-Wasser-Heizung-System verbunden werden.<\/p>\n<p>4.  Alle Wasser-Zugangsteile sind aus Edelstahl, um sicher, gesund und nicht-Verschmutzung zu halten<\/p>\n<p><strong>\u00a0<\/strong><strong>Qualit\u00e4t f\u00fcr Zuverl\u00e4ssigkeit und sparen Wartung Kosten:<br \/>\n<\/strong>\u00a0 Unsere Teile sind immer choosend mit die top Marke in der Welt<br \/>\nW\u00e4rmetauscher:\u00a0<strong>SWEP<\/strong>\u00a0Marken-Plattenw\u00e4rmetauscher aus Schweden.<br \/>\nW\u00e4rme expansion Ventil:\u00a0<strong>Emerson<\/strong>\u00a0Marke<br \/>\nVier-Wege-Ventil:\u00a0<strong>Saginomiya\u00a0<\/strong>Marke Japans<br \/>\nDie oben genannten Teile damit unsere W\u00e4rmepumpe zu werden st\u00f6rungsfreien Produkte.<\/p>\n<p>Daten zur W\u00e4rmepumpe:<\/p>\n<table style=\"width: 501px; height: 587px;\" width=\"501\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"237\" \/>\n<col width=\"153\" \/>\n<col width=\"157\" \/>\n<col span=\"3\" width=\"120\" \/><\/colgroup>\n<tbody>\n<tr>\n<td width=\"237\" height=\"28\">Modelle<\/td>\n<td width=\"153\">Lufttemperatur\/Wasseraustrittstemperatur<\/td>\n<td width=\"157\">AH-6AC-410DC<\/td>\n<td width=\"120\">AH-9AC-410DC<\/td>\n<td width=\"120\">AH-11AC-410DC<\/td>\n<td width=\"120\">AH-15AC-410DC<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" width=\"237\" height=\"80\">Heizleistung \/ Eingangsleistung \/ COP (KW)<\/td>\n<td>bei A20\/W35\u00b0C<\/td>\n<td width=\"157\">8.85\/1.49\/5.94<\/td>\n<td width=\"120\">12.06\/1.69\/7.14<\/td>\n<td width=\"120\">13\/2.67\/4.87<\/td>\n<td width=\"120\">18.4\/3.92\/4.69<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">bei A7\/W35\u00b0C<\/td>\n<td width=\"157\">6.57\/1.32\/4.98<\/td>\n<td width=\"120\">8.95\/1.5\/5.97<\/td>\n<td width=\"120\">10.6\/2.5\/4.24<\/td>\n<td width=\"120\">14.6\/3.71\/3.94<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">bei A7\/W45\u00b0C<\/td>\n<td width=\"157\">6.25\/1.55\/4.03<\/td>\n<td width=\"120\">8.51\/1.76\/4.84<\/td>\n<td width=\"120\">9.86\/3.03\/3.25<\/td>\n<td width=\"120\">12.9\/3.63\/3.55<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">bei A2\/W35\u00b0C<\/td>\n<td width=\"157\">5.85\/1.28\/4.57<\/td>\n<td width=\"120\">7.97\/1.45\/5.5<\/td>\n<td width=\"120\">9.02\/2.57\/3.51<\/td>\n<td width=\"120\">12.99\/3.59\/3.62<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">bei A2\/W45\u00b0C<\/td>\n<td width=\"157\">5.56\/1.5\/3.71<\/td>\n<td width=\"120\">7.57\/1.7\/4.45<\/td>\n<td width=\"120\">8.8\/2.86\/3.08<\/td>\n<td width=\"120\">11.66\/3.74\/3.12<\/td>\n<\/tr>\n<tr>\n<td width=\"237\" height=\"32\">K\u00fchlleistung\/Eingangsleistung\/ EER<\/td>\n<td>bei A35\/ W18\u00baC<\/td>\n<td width=\"157\">6.51\/1.4\/4.65<\/td>\n<td width=\"120\">8.14\/1.78\/4.57<\/td>\n<td width=\"120\">10.81\/2.60\/4.16<\/td>\n<td width=\"120\">15.2\/3.98\/3.82<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" height=\"16\">Max. Stromst\u00e4rke (A)<\/td>\n<td>9.5<\/td>\n<td>12<\/td>\n<td>15<\/td>\n<td>22<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" height=\"16\">Elektrische Versorgung<\/td>\n<td colspan=\"4\">230V\/50-60Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" height=\"19\">Max. Wassertemperatur ( <span><sup>o<\/sup><\/span><span>C<\/span><span>)<\/span><\/td>\n<td colspan=\"4\">60<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" height=\"18\">Betriebstemperaturbereich (<span><sup>o<\/sup><\/span><span>C<\/span><span>)<\/span><\/td>\n<td colspan=\"4\">-25 ~ 43<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" height=\"66\">K\u00e4ltemittelkreislauf<\/td>\n<td>K\u00e4ltemittel<\/td>\n<td colspan=\"4\">R410a<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">DC-Wechselrichter <span>Kompressor(en)<\/span><\/td>\n<td>Doppelt rotierend<\/td>\n<td>Doppelt rotierend<\/td>\n<td>Doppelt rotierend<\/td>\n<td>Schriftrolle<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">W\u00e4rmeaustausch<\/td>\n<td colspan=\"4\">Kupfer und hydrophile Aluminiumrippen<\/td>\n<\/tr>\n<tr>\n<td height=\"18\">Luftstrom (m<span><sup>3<\/sup><\/span><span>\/h)<\/span><\/td>\n<td>2100<\/td>\n<td>2400<\/td>\n<td>2900<\/td>\n<td>4000<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" height=\"68\">Wasserkreislauf<\/td>\n<td>W\u00e4rmetauscher<\/td>\n<td colspan=\"4\" width=\"517\">Plattenw\u00e4rmetauscher<\/td>\n<\/tr>\n<tr>\n<td height=\"16\">Eingangs-\/Ausgangsrohr<\/td>\n<td>DN20(3\/4\")<\/td>\n<td>DN20(3\/4\u2033)<\/td>\n<td colspan=\"2\">DN25(1\")<\/td>\n<\/tr>\n<tr>\n<td height=\"18\">Wasserdurchfluss (m3\/h)<\/td>\n<td><span>?<\/span><span>0.8<\/span><\/td>\n<td><span>?<\/span><span>1.2<\/span><\/td>\n<td><span>?<\/span><span>1.8<\/span><\/td>\n<td><span>?<\/span><span>2<\/span><\/td>\n<\/tr>\n<tr>\n<td height=\"18\">zul\u00e4ssiger Druck<\/td>\n<td colspan=\"4\"><span>?<\/span><span>0,8MPa<\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" height=\"16\">Abmessungen der Einheit Bx<span>Hx<\/span><span>D<\/span><span>\u00a0\u00a0 (mm)<\/span><\/td>\n<td>8<span>55<\/span><span>x6<\/span><span>35<\/span><span>x<\/span><span>335<\/span><\/td>\n<td>850x850x310<\/td>\n<td>880*1090*400<\/td>\n<td width=\"120\">1016*1090*462<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" height=\"16\">Abmessungen des Pakets W<span>xHx<\/span><span>D<\/span><span>\u00a0\u00a0 (mm)<\/span><\/td>\n<td>985x745x410<\/td>\n<td>985x980x410<\/td>\n<td>1035**1190*508<\/td>\n<td>1170<span>*1180*<\/span><span>530<\/span><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" height=\"16\">Nettogewicht (kg)<\/td>\n<td>45<\/td>\n<td>64<\/td>\n<td>95<\/td>\n<td>140<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" height=\"16\">Bruttogewicht (kg)<\/td>\n<td>50<\/td>\n<td>75<\/td>\n<td>115<\/td>\n<td>150<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" height=\"16\">Ger\u00e4uschpegel (dB(A))<\/td>\n<td>46<\/td>\n<td>49<\/td>\n<td>50<\/td>\n<td>52<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" height=\"16\">Ladungsmenge f\u00fcr 20'\/40\u2032<\/td>\n<td>60\/120<\/td>\n<td>6<span>0\/120<\/span><\/td>\n<td>54\/108<\/td>\n<td>42\/84<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>COP 5.97 for 9KW DC\u00a0Inverter\u00a0air source\u00a0Heat Pump with Heating and Cooling and domestic hot water\u00a0functions, R410a,\u00a0 With most advance European [&hellip;]<\/p>","protected":false},"author":2,"featured_media":3552,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[29,138,119],"tags":[194,117,80],"faqcat":[],"class_list":["post-1696","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-heating-knowledge","category-highest-cop-heat-pump-2","category-r290-inverter-multifunctional-monobloc-heat-pump","tag-dc-inverter-air-to-water-heat-pump","tag-dc-inverter-heat-pump","tag-high-cop-heat-pump"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.china-heatpump.com\/de\/wp-json\/wp\/v2\/posts\/1696","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.china-heatpump.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.china-heatpump.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.china-heatpump.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.china-heatpump.com\/de\/wp-json\/wp\/v2\/comments?post=1696"}],"version-history":[{"count":0,"href":"https:\/\/www.china-heatpump.com\/de\/wp-json\/wp\/v2\/posts\/1696\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.china-heatpump.com\/de\/wp-json\/wp\/v2\/media\/3552"}],"wp:attachment":[{"href":"https:\/\/www.china-heatpump.com\/de\/wp-json\/wp\/v2\/media?parent=1696"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.china-heatpump.com\/de\/wp-json\/wp\/v2\/categories?post=1696"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.china-heatpump.com\/de\/wp-json\/wp\/v2\/tags?post=1696"},{"taxonomy":"faqcat","embeddable":true,"href":"https:\/\/www.china-heatpump.com\/de\/wp-json\/wp\/v2\/faqcat?post=1696"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}