{"id":1693,"date":"2013-06-28T15:03:37","date_gmt":"2013-06-28T07:03:37","guid":{"rendered":"\/?p=925"},"modified":"2025-12-03T16:06:47","modified_gmt":"2025-12-03T08:06:47","slug":"trinity-air-water-heat-pump-with-inner-buffer-tank","status":"publish","type":"post","link":"https:\/\/www.china-heatpump.com\/de\/trinity-air-water-heat-pump-with-inner-buffer-tank\/","title":{"rendered":"Trinity Luft-Wasser-W\u00e4rmepumpe mit Innenpufferspeicher"},"content":{"rendered":"<p><img decoding=\"async\" alt=\"combined heating cooling and hot water heatpump\" src=\"\/UploadProductPic\/AH17D-buffer-tank-heat-pump.jpg \" \/><br \/>\n<strong><img decoding=\"async\" alt=\"combined heating cooling and hot water heatpump\" src=\"\/UploadProductPic\/combined%20heating%20cooling%20and%20hot%20water%20heatpump.jpg\" \/><\/strong><\/p>\n<p>&nbsp;<\/p>\n<p>1. zentrale Heizung, K\u00fchlung und Warmwasser mit einem AC-Pufferspeicher und Ausdehnungsgef\u00e4\u00df f\u00fcr eine einfache Installation.<\/p>\n<p>2. Mit 2 Wasserumw\u00e4lzpumpen im Inneren.  Alle Wasserpumpen stoppen, um Energie zu sparen, wenn die Raumtemperatur erreicht ist.   Alle Wasserpumpen k\u00f6nnen starten, wenn der Raum ben\u00f6tigt wird.<\/p>\n<p>3. Heizung K\u00fchlung und Warmwasser multifunktionale W\u00e4rmepumpe verf\u00fcgbar f\u00fcr 17KW<\/p>\n<p>3. Intelligenter automatischer Betriebsmodus von Warmwasser und Raumheizung f\u00fcr mehr Energieeinsparung bei unterschiedlichen Umgebungstemperaturen;<\/p>\n<p>4. Intelligente automatische Abtauung, Frostschutz f\u00fcr den Betrieb bei niedrigen Umgebungstemperaturen bis zu minus -15 Grad.<\/p>\n<p>5. Echte Wochenzeitschaltuhr-verschiedene Einstellung f\u00fcr jeden Tag der Woche, um Ihre Lebensgewohnheit die meisten passen und Energie zu sparen. Wenn Sie Ihr Wochenende im Urlaub mit Ihrer Familie genie\u00dfen wollen, muss die W\u00e4rmepumpe am Wochenende nicht eingeschaltet werden.  Der w\u00f6chentliche Timer verliert nicht den Speicher, wenn der Strom abgeschaltet wird.<\/p>\n<p>6. alle Fehlercodes k\u00f6nnen \u00fcber das Controller-Display \u00fcberpr\u00fcft werden, so dass Sie das Problem so schnell wie m\u00f6glich l\u00f6sen k\u00f6nnen.<\/p>\n<p>Technische Daten<\/p>\n<table style=\"width: 635px; height: 663px;\" border=\"1\">\n<colgroup>\n<col width=\"167\" \/>\n<col width=\"178\" \/>\n<col width=\"195\" \/>\n<col width=\"53\" \/><\/colgroup>\n<tbody>\n<tr>\n<td width=\"167\" height=\"32\">Muster Nr.<\/td>\n<td width=\"178\">Bei Lufttemperatur\/Austrittstemperatur des Wassers<\/td>\n<td width=\"195\">AHP-17D-410S<\/td>\n<td width=\"53\"><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" width=\"167\" height=\"84\">Heizleistung\/Eingangsleistung (KW\/KW)<\/td>\n<td width=\"178\">Bei A20\u00baC\/W45\u00baC<\/td>\n<td width=\"195\">18.5\/4.63<\/td>\n<td width=\"53\">4<\/td>\n<\/tr>\n<tr>\n<td width=\"178\" height=\"21\">Bei A7\u00baC\/W45\u00baC<\/td>\n<td width=\"195\">15.1\/4.5<\/td>\n<td width=\"53\">3.36<\/td>\n<\/tr>\n<tr>\n<td width=\"178\" height=\"21\">*bei A7\u00baC\/W35\u00baC<\/td>\n<td width=\"195\">16.95\/3.96<\/td>\n<td width=\"53\">4.28<\/td>\n<\/tr>\n<tr>\n<td width=\"178\" height=\"21\">Bei A2\u00baC\/W<span>35\u00baC<\/span><\/td>\n<td>14.79\/4.0<\/td>\n<td width=\"53\">3.7<\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"42\">K\u00fchlleistung\/Eingangsleistung (KW\/KW)<\/td>\n<td width=\"178\">Bei A35\u00baC\/W18\u00baC<\/td>\n<td width=\"195\">17.8\/4.8<\/td>\n<td width=\"53\"><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"167\" height=\"65\">Stromversorgung<\/td>\n<td width=\"178\"><\/td>\n<td width=\"195\">2<span>30V oder <\/span><span>380V\/50HZ<\/span><\/td>\n<td width=\"53\"><\/td>\n<\/tr>\n<tr>\n<td width=\"178\" height=\"33\">verf\u00fcgbares Modell f\u00fcr 60hz<\/td>\n<td width=\"195\"><\/td>\n<td width=\"53\"><\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"19\">Arbeitsbereich<\/td>\n<td width=\"178\">\u00baC<\/td>\n<td colspan=\"2\" width=\"248\">-15 ~ 43<\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"19\">Max. Ausgangswassertemperatur<\/td>\n<td width=\"178\">\u00baC<\/td>\n<td colspan=\"2\" width=\"248\">60<\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"32\">Mini-Wasserdurchfluss<br \/>\n(Heizung und K\u00fchlung)<\/td>\n<td width=\"178\">M3\/h<\/td>\n<td width=\"195\">&gt;=3<\/td>\n<td width=\"53\"><\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"19\">Wasseranschlussverbindung<\/td>\n<td width=\"178\">mm<\/td>\n<td width=\"195\">DN25<\/td>\n<td width=\"53\"><\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"16\">Packungsgr\u00f6\u00dfe<\/td>\n<td width=\"178\">mm<\/td>\n<td width=\"195\">530*1<span>2<\/span><span>80*1430<\/span><\/td>\n<td width=\"53\"><\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"20\">Gr\u00f6\u00dfe der Einheit<\/td>\n<td width=\"178\">mm<\/td>\n<td width=\"195\">462*1<span>1<\/span><span>90*1272<\/span><\/td>\n<td width=\"53\"><\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"19\">Schutzklasse<\/td>\n<td width=\"178\"><\/td>\n<td colspan=\"2\" width=\"248\">IPx4<\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"19\">Anti-Schock-Klasse<\/td>\n<td width=\"178\"><\/td>\n<td colspan=\"2\" width=\"248\">Klasse 1<\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"19\">K\u00e4ltemittel<\/td>\n<td width=\"178\"><\/td>\n<td colspan=\"2\" width=\"248\">R410a<\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"16\">L\u00e4rm<\/td>\n<td width=\"178\">dB<\/td>\n<td width=\"195\">45<\/td>\n<td width=\"53\"><\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"38\">Komponente Regulierung<\/td>\n<td width=\"178\"><\/td>\n<td colspan=\"2\" width=\"248\">Emersion Expansionsventil<\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"16\">Kompressor-Typ<\/td>\n<td width=\"178\"><\/td>\n<td colspan=\"2\" width=\"248\">Schriftrolle<\/td>\n<\/tr>\n<tr>\n<td width=\"167\" height=\"31\">Heizung K\u00fchlung W\u00e4rmetauscher<\/td>\n<td width=\"178\"><\/td>\n<td colspan=\"2\" width=\"248\">Plattenw\u00e4rmetauscher<\/td>\n<\/tr>\n<tr>\n<td height=\"28\">Ladungsmenge f\u00fcr 20'\/40\u2032<\/td>\n<td>St\u00fcck<\/td>\n<td>21\/42<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td height=\"28\">Bruttogewicht<\/td>\n<td>k<span>g<\/span><\/td>\n<td>185<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"345\" height=\"28\">Anmerkung:<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"345\" height=\"84\">1.  In der obigen Liste sind alle Daten unter verschiedenen Bedingungen aufgef\u00fchrt.  Zum Beispiel: AT A7\u00baC\/W35\u00baC , bedeutet, dass die Testbedingung eine Lufttemperatur von 7\u00baC und eine Wassertemperatur von 35\u00baC gem\u00e4\u00df der Norm EN14511 ist.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"345\" height=\"58\">2.2 Zirkulationswasserpumpen mit 1 Pufferspeicher im Inneren. Die 2 Wasserpumpen werden gestoppt, wenn die Raumtemperatur die Zieltemperatur erreicht.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>PR\u00dcFUNG NACH der europ\u00e4ischen W\u00e4rmepumpennorm EN14511 STANDARDBEDINGUNG<\/p>","protected":false},"excerpt":{"rendered":"<p>&nbsp; 1.Central heating cooling and DHW with one AC buffer\u00a0tank\u00a0and expansion tank for easy installation. 2. With 2 circulation water pumps inside.\u00a0 All water pumps will stop to save energy when room temp is reached.\u00a0\u00a0 All water pumps can start when room required. 3. Heating Cooling and domestic hot water multifunctional Heat Pump available for<span class=\"excerpt-hellip\"> [...]<\/span><\/p>","protected":false},"author":2,"featured_media":4762,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[87],"tags":[155,171,172,99],"class_list":["post-1693","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-air-source-heat-pump","tag-air-water-heat-pump","tag-central-heating-cooling-heat-pump","tag-heat-pump-with-inner-buffer-tank","tag-multifunctional-heat-pump"],"_links":{"self":[{"href":"https:\/\/www.china-heatpump.com\/de\/wp-json\/wp\/v2\/posts\/1693","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.china-heatpump.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.china-heatpump.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.china-heatpump.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.china-heatpump.com\/de\/wp-json\/wp\/v2\/comments?post=1693"}],"version-history":[{"count":1,"href":"https:\/\/www.china-heatpump.com\/de\/wp-json\/wp\/v2\/posts\/1693\/revisions"}],"predecessor-version":[{"id":4763,"href":"https:\/\/www.china-heatpump.com\/de\/wp-json\/wp\/v2\/posts\/1693\/revisions\/4763"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.china-heatpump.com\/de\/wp-json\/wp\/v2\/media\/4762"}],"wp:attachment":[{"href":"https:\/\/www.china-heatpump.com\/de\/wp-json\/wp\/v2\/media?parent=1693"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.china-heatpump.com\/de\/wp-json\/wp\/v2\/categories?post=1693"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.china-heatpump.com\/de\/wp-json\/wp\/v2\/tags?post=1693"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}