Two-stage cascade compression technology, multi-stage refrigerant heat exchange reduces the compression ratio of the unit operation, greatly improves the low-temperature operation ability and efficiency of the unit, and innovatively realizes the ambient temperature of -35℃ and the outlet water temperature of the unit reaches 90℃, replacing the heating boiler in extremely cold areas.
Get Free Quote

Striking characters distinguishing from other products.


85~90C outlet water temp at -35C.
Both stages adopt industry-leading ultra-low temperature DC inverter and low temperature enhanced vapor injection technology.
Built-in internet WIFI control make the heat pump operation status information to be seen at a glance at thousands of miles away.

Kolant heat pump installation project reference

Commercial 90oC high temp hot water cascade compression heat pump Specification

model KRS-500E/SN3-MFD KRS-800E/SN3-VFD KRS.85OE/SN3-VFD-BP
Rated heating capacity(kw) 50 80 85
Rated heating power (kW) 16.67 26.68 27.42
Rated heating current(A) 29.8 47.69 49.01
Low temperature 1 heating capacity (kw) 40 64 68
Low temperature 1 heating power (kW) 18.18 29.09 29.56
Low temperature 1 heating current (A) 32.5 52 52.84
Low temperature 2 heating capacity (kW) 36 57 60
Low temperature 2 heating power (kW) 20 31.7 31.58
Low temperature 2 heating current (A) 35.75 56.66 56.45
Maximum input power (kW) 25 40.02 41.13
Maximum input current (A) 44.7 71.5 73.5
Maximum water outlet temperature 85 85 90
Refrigerant Type R410A+R134A R410A+R134A R410A+R134A
Noise dB(A) 60 70 72
Weight(kg) 410 810 800
Product size L x W x H {mm) 1450X702X1260 2100X1050x2120 1300*1300*2445
       
Water pipe size Female thread DN40 Flange DN65 Female thread DN65
Water flow (m3/h) 8.6 13.8 14.7
Water resistance value (kpa) 65 80 100
Rated COP 3 3 3.1
power supply 380V/50Hz 380V/50Hz 380V/50Hz

Rated working conditions: ambient dry bulb temperature 7°C, water inlet temperature 9°C, water outlet temperature 65°C
Low temperature condition 1: ambient dry bulb temperature -12°C, water inlet temperature 6°C, water outlet temperature 65°C
Low temperature condition 2: ambient dry bulb temperature -12°C, water inlet temperature 75°C, water outlet temperature 80°C
As the ambient temperature changes, the unit capacity also changes If the specifications and parameters are changed due to product improvement, the actual nameplate parameters shall prevail.