China Europe Joint Venture Manufacturer-Original European Technology

Heat pump-central air conditioner

combined heating cooling and hot water heatpump

Heating Cooling Heat Pump Which can be used for room heating and cooling like central air conditioner.

1. Heat pump with combined Heating, cooling air conditoner and domestic hot water function in one solution for all family requirement in whole year.

2. Built inside fuzzy logic solar combination operation utilize solar for both room heating and domestic hot water, which enable more energy saving than other heat pump.

3. Intelligent automatic operation mode of DHW and room heating for more energy saving during different ambient temp;

4. Intelligent auto defrost, antifreeze protection for low ambient temp operation to minus -15.

5. Real weekly timer-Different setting for every day of the week to fit your life habit the most and save energy. Imaging you will enjoy your weekend in tourism with your sweet family, then the heat pump doesn't need to start at weekend.

6. More energy saving and much more comfortable than normal air conditioner;

7.All error code can be checked through controller display which enable you to solve the problem as soon as possible.

Model No Test Condition
Air temp/Oulet water temp
AH-3.5D AH-4.5H AH-7H AH-12H AH-14H AH-17H AH-21H AH-30H
Heating Capcity/Input Power (KW/KW) At A20/W55ºC 3.5/0.8 4.5/1.02 7.05/1.6 12/2.5 14/3.1 17/3.9 21/4.9 30/6.6
At  A7/W35ºC 2.5/0.6 3.8/0.98 5.7/1.5 9/2.14 10.85/2.3 15/3.53 17/4.1 23/5.3
At  A2/W35ºC 1.8/0.58 3.2/0.95 4.89/1.45 7.6/2 8.9/2.27 12.5/3.28 15.1/3.95 20.4/5.2
Cooling Capcity(KW) At  A35/W18ºC 2.6/0.72 4.1/1.15 6.1/1.76 9.1 11.5 15.6 19 24
Power Supply 220V/50HZ 220V or 380V/50HZ 380V/50HZ
Working Range ºC -15 ~ 43
Max Output water temp ºC 60
Mini water flow(L/H)
(Heating- cooling)
M3/hour >=0.35 >=0.6 >=0.8 >=1.2 >=1.8 >=2.4 >=3 >=3.5
Water connection joint mm DN20(3/4'') DN25 DN32
Packing size mm 360*650*790 430*695 *1010 430*695 *1010 415*980 *985 465*1085 *1085 530*1180 *1170 530*1180 *1430 530*1180 *1630
Unit size mm 254*540*772 290*605*850 290*605 *850 325*860 *870 345*960 *970 462*1090 *1016 462*1090 *1272 462*1090 *1475
Protection class IPx4
Anti Shock class Class 1
Refrigerant R410a
Noise dB 40 42 45 48 55 56 57 58
Regulation component Emersion Expansion valve
Compressor type Rotary Scroll
Heating Cooling heat exchanger Stainless Steel Plate Heat exchanger
Loading quantity for 20'/40' pcs 138/276 90/180 90/180 64/128 54/108 42/84 21/42 21/42

Warranty

We provide 1% free spareparts and 1 year warranty for factory fault since shipment arrival.

We will send the spare parts by courrier method after confirm it is due to factory fault.

We don't cover the cost for failure from shipment, wrong installation and incorrect usage. Of course we can provide parts by customer's cost after warranty period.

Customer Service

We can provide free heat pump installation consultation.

We can provide after sales service, technical assistant.
We can help to purchase other parts related to heat pumps or recommand reliable suppliers directly.

Shipping

For heat pump samples delivery, after packing with export class thick 5 layers paper box, we will pack heat pumps with poly wood case to avoid any damage as shown attached.

There are two ways to delivery the samples.

For sea freight, we will keep the refrigerant inside of the heat pump.

For air freight cargo, due to the air line regulation, we need to drain out the refrigerant. So you need to charge the refrigerant if you find the heat pump cannot start.
For all products above 50kg, we will fix it on a good structured wood or polywood pallet as shown below.

For Container delivery, we use only export thick 5 layer paper box. After carefully loading, we will take pictures before close the container door to assure everything is ok.

If by sea, normally we export at EXW, FOB or CFR terms, we only delivery goods to the destination sea port. The customers need to cover cost for their import duty and cost. Of course the customers can use our forwarder agent to help you to clear the customs.
We can provide all necessary document such as Form A, certificate of origin, Bill of lading, Invoice and packing list.

Normally it will take about 30 days by sea and one week by air.

Triaqua Monobloc heat pump-one inner water tank with expansion tank

combined heating cooling and hot water heatpump

1.Triaqua Monobloc heat pump-one inner water tank with expansion tank for easy installation.

2.Heating Cooling and domestic hot water multifunctional  Heat Pump available for 11KW,14KW,17KW,20KW,23KW

3. Intelligent automatic operation mode of DHW and room heating for more energy saving during different ambient temp;

4. Intelligent auto defrost, antifreezeprotection for low ambient temp operation to minus -15.

5. Real weekly timer-Different setting for every dayof the week to fit your life habit the most and save energy. Imaging you will enjoy your weekend in tourism with your sweet family, then the heat pump doesn't need to start at weekend.

6.All error code can be checked through controller display which enable you to solve the problem as soon as possible.

Technical data HLR-110D HLR-140D HLR-170D HLR-200D HLR-230D
Floor heating Capacity KW 11.1 14.52 18.00 21.00 23.90
Power Input KW 2.64 3.30 4.21 4.81 5.41
COP 4.2 4.40 4.28 4.37 4.42
Floor cooling Capacity KW 12.1 15.00 17.50 20.00 23.00
Power Input KW 3.1 3.94 4.56 5.17 5.88
EER 3.9 3.81 3.84 3.87 3.91
Domestic hot water Capacity KW 11 14.08 16.50 19.20 21.80
Power Input KW 2.89 3.75 4.33 5.07 5.74
COP 3.8 3.75 3.81 3.79 3.80
Power supply V/Ph/Hz 230/1/50 380/3/50
Refrigerant R410
 
Compressor Type Scroll Scroll Scroll Scroll Scroll
Air conditioning tank volume L 20 20 25 30 30
Dimensiones LXHXD mm 1090X1000X450 1090X1260X450 1090X1460X450
Weight Kg 110 125 165 190 205
Noise dB(A) 48 51 50 53 53
Loading QTY 20'SQ/40'HQ PCS 36/82 36/82 18/41 18/41 18/41

TEST UNDER European heat pump standard EN14511 STANDARD CONDITION:

Floor Heating: 7°C Outdoor  air / 35°C Leaving water.
Floor cooling: 35°C Outdoor air / 18°C Leaving water..
Domestic Hot Water: 7°C Outdoor air / 40°C Water in the tank.

combined-heating-cooling-and-hot-water-heat-pump-17kw

combined heating cooling and hot water air water heatpump

Heating Cooling Heat Pump available for 2KW,3.5KW,4.5KW,7KW,9KW,11KW,14KW,17KW,20KW,22KW,30,40KW

1. Heat pump with combined Heating, cooling and domestic hot waterfunction in one solution for all family requirement in whole year.

2. Built inside fuzzy logic solar combination operation utilize solar for both room heating and domestic hot water, which enable more energy saving than other heat pump.

3. Intelligent automatic operation modeof DHW and room heating for more energy saving during different ambient temp;

4. Intelligent auto defrost, antifreezeprotection for low ambient temp operation to minus -15.

5. Real weekly timer-Different setting for every dayof the week to fit your life habit the most and save energy. Imaging you will enjoy your weekend in tourism with your sweet family, then the heat pump doesn't need to start at weekend.

6. More energy saving and much more comfortable than normal air conditioner;

7.All error code can be checked through controller display which enable you to solve the problem as soon as possible.

Model No Test Condition
Air temp/Oulet water temp
AH-3.5H AH-4.5H AH-7H AH-12H AH-14H AH-17H AH-21H AH-30H
Heating Capcity/Input Power (KW/KW) At A20/55ºC 3.5/0.8 4.5/1.02 7.05/1.6 12/2.5 14/3.1 17/3.9 21/4.9 30/6.6
At  A7/35ºC 2.5/0.6 3.8/0.98 5.7/1.5 9/2.14 10.85/2.3 15/3.53 17/4.1 23/5.3
At  A2/35ºC 1.8/0.58 3.2/0.95 4.89/1.45 7.6/2 8.9/2.27 12.5/3.28 15.1/3.95 20.4/5.2
Cooling Capcity(KW) At  A35/18ºC 2.6/0.72 4.1/1.15 6.1/1.76 9.1 11.5 15.6 19 24
Power Supply 220V/50HZ 220V or 380V/50HZ 380V/50HZ
Working Range ºC -15 ~ 43
Max Output water temp ºC 60
Mini water flow(L/H)
(Heating- cooling)
M3/hour >=0.35 >=0.6 >=0.8 >=1.2 >=1.8 >=2.4 >=3 >=3.5
Water connection joint mm DN20(3/4'') DN25 DN32
Packing size mm 360*650*790 430*695 *1010 430*695 *1010 415*980 *985 465*1085 *1085 530*1180 *1170 530*1180 *1430 530*1180 *1630
Unit size mm 254*540*772 290*605*850 290*605 *850 325*860 *870 345*960 *970 462*1090 *1016 462*1090 *1272 462*1090 *1475
Protection class IPx4
Anti Shock class Class 1
Refrigerant R410a
Noise dB 40 42 45 48 55 56 57 58
Regulation component Emersion Expansion valve
Compressor type Rotary Scroll
Heating Cooling heat exchanger Stainless Steel Plate Heat exchanger
Loading quantity for 20'/40' pcs 138/276 90/180 90/180 64/128 54/108 42/84 21/42 21/42

Two Years Warranty !

We provide 1% free spareparts with containered order and 2 year warranty of main parts for factory fault since shipment arrival.

We will send the spare parts by courrier method after confirm it is due to factory fault.

We don't cover the cost for failure from shipment, wrong installation and incorrect usage. Of course we can provide parts by customer's cost after warranty period.

Customer Service

We can provide free heat pump installation consultation.

We can provide after sales service, technical assistant.

We can help to purchase other parts related to heat pumps or recommand reliable suppliers directly.

Shipping

For heat pump samples delivery, after packing with export class thick 5 layers paper box, we will pack heat pumps with poly wood case to avoid any damage as shown attached.

There are two ways to delivery the samples.

For sea freight, we will keep the refrigerant inside of the heat pump.

For air freight cargo, due to the air line regulation, we need to drain out the refrigerant. So you need to charge the refrigerant if you find the heat pump cannot start.

For all products above 50kg, we will fix it on a good structured wood or polywood pallet as shown below.

For Container delivery, we use only export thick 5 layer paper box. After carefully loading, we will take pictures before close the container door to assure everything is ok.

If by sea, normally we export at EXW, FOB or CFR terms, we only delivery goods to the destination sea port. The customers need to cover cost for their import duty and cost. Of course the customers can use our forwarder agent to help you to clear the customs.

We can provide all necessary document such as Form A, certificate of origin, Bill of lading, Invoice and packing list.

Normally it will take about 30 days by sea and one week by air.

Combined heating cooling and hot water heat pump 2kw-30kw

combined heating cooling and hot water heatpump

Heating Cooling Heat Pump available for 2KW,3.5KW,4.5KW,7KW,9KW,11KW,15KW,17KW,20KW,22KW,30,40KW

1. Heat pump with combined Heating, cooling and domestic hot water function in one solution for all family requirement in whole year.

2. Built inside fuzzy logic solar combination operation utilize solar for both room heating and domestic hot water, which enable more energy saving than other heat pump.

3. Intelligent automatic operation mode of DHW and room heating for more energy saving during different ambient temp;

4. Intelligent auto defrost, antifreeze protection for low ambient temp operation to minus -15.

5. Real weekly timer-Different setting for every day of the week to fit your life habit the most and save energy. Imaging you will enjoy your weekend in tourism with your sweet family, then the heat pump doesn't need to start at weekend.

6. More energy saving and much more comfortable than normal air conditioner;

7.All error code can be checked through controller display which enable you to solve the problem as soon as possible.

Two Years Warranty !

We provide 1% free spareparts with containered order and 2 year warranty of main parts for factory fault since shipment arrival.

We will send the spare parts by courrier method after confirm it is due to factory fault.

We don't cover the cost for failure from shipment, wrong installation and incorrect usage. Of course we can provide parts by customer's cost after warranty period.

Customer Service

We can provide free heat pump installation consultation.

We can provide after sales service, technical assistant.

We can help to purchase other parts related to heat pumps or recommand reliable suppliers directly.

Shipping

For heat pump samples delivery, after packing with export class thick 5 layers paper box, we will pack heat pumps with poly wood case to avoid any damage as shown attached.

There are two ways to delivery the samples.

For sea freight, we will keep the refrigerant inside of the heat pump.

For air freight cargo, due to the air line regulation, we need to drain out the refrigerant. So you need to charge the refrigerant if you find the heat pump cannot start.

For all products above 50kg, we will fix it on a good structured wood or polywood pallet as shown below.

For Container delivery, we use only export thick 5 layer paper box. After carefully loading, we will take pictures before close the container door to assure everything is ok.

If by sea, normally we export at EXW, FOB or CFR terms, we only delivery goods to the destination sea port. The customers need to cover cost for their import duty and cost. Of course the customers can use our forwarder agent to help you to clear the customs.

We can provide all necessary document such as Form A, certificate of origin, Bill of lading, Invoice and packing list.

Normally it will take about 30 days by sea and one week by air.

Heating Cooling Hot Water MonoBloc HeatPump 14KW-product-176


Heating Cooling heat pump available for 11KW,14KW,17KW,20KW,23KW
A.Heat pump with Heating, cooling and domestic hot water function in one solution.
B. One water tank built inside
C. More Operation Mode for heat pump:
DHW automatic operation mode for more energy saving;
Air heating automatic operation mode to achieve more energy saving;
Great economical air heating mode to keep comfortable feeling with most energy saving;

D.More advanced timer setting function for heat pump:
1.Single day timer
Three periods on and off setting (Avoid electric peak time to use the cheapest electric and save your bill the most)
2.Weekly timer
Different setting for every day of the week. Totally 42 timer period available for setting

E.Great phone remote control function for heat pump
Control the operation and check the operation mode through simple phone call.

F.Protection function and Error code display for heat pump
1.Pressure, miss phase, wrong phase and high temp protection, water flow protection, antifreeze protection.
2.All error can be checked through controller and error LED light.
G. Historical memory for all heat pump operation for long years. 

 

 
Mini Chiller SPECIFICATION
Technical data HLR-110D HLR-140D HLR-170D HLR-200D HLR-230D
Floor heating Capacity KW                   11.50                   14.30                   18.00                   21.00                   23.90
Power Input KW                     2.70                     3.70                     4.20                     4.80                     5.40
COP                       4.26                     3.82                     4.28                     4.37                     4.42
Fan coil heating Capacity KW                   10.30                   13.50                   16.60                   19.50                   22.80
Power Input KW                     3.00                     3.80                     4.70                     5.70                     6.80
COP                       3.43                     3.55                     3.53                     3.42                     3.35
Floor cooling Capacity KW                   11.00                   15.00                   17.50                   20.00                   23.00
Power Input KW                     3.10                     4.40                     4.80                     5.30                     6.10
EER                       3.55                     3.41                     3.64                     3.77                     3.77
Fan coil cooling Capacity KW                     8.80                   12.30                   15.50                   17.50                   20.80
Power Input KW                     2.90                     4.00                     4.90                     5.50                     7.10
EER                       3.03                     3.07                     3.16                     3.18                     2.93
Domestic hot water Capacity KW                   10.40                   13.50                   16.50                   19.20                   21.80
Power Input KW                     2.80                     3.80                     4.80                     5.60                     6.60
COP                       3.71                     3.55                     3.44                     3.43                     3.30
Power supply   V/Ph/Hz 230/1/50 380/3/50 380/3/50
Refrigerant     R410A
Compressor Brand     Daikin  Daikin  SANYO  Daikin  SANYO 
Compressor Type     Scroll Scroll  Scroll Scroll  Scroll
Air conditioning tank volume   L 17 20 25 30 30
Dimensiones LXHXD mm 1090X900X450 1090X1000X450 1090X1260X450 1090X1460X450 1090X1460X450
Weight   Kg 110 125 165 190 205
Noise   dB(A) 48 51 50 53 53
Loading QTY  20'SQ/40'HQ PCS 36/82 36/82 18/41 18/41 18/41
               
Floor Heating: 7ºC Outdoor  air / 35ºC Leaving water.  Heating (Fan Coil): 7ºC Outdoor air / 45ºC Leaving water. 
Floor cooling: 35ºC Outdoor air / 16ºC Leaving water..  Cooling (Fan Coil): 35ºC Outdoor  air / 7ºC Leaving water.. 
Domestic Hot Water: 7ºC Outdoor air / 40ºC Water in the tank.   

Heat Pump Mini Chiller Heating-Cooling-DHW-17-23KW-product-158

   


Heating Cooling Heat Pump available for 11KW,14KW,17KW,20KW,23KW
DHW automatic operation mode for more energy saving;
Air heating automatic operation mode to achieve more energy saving;
Great economical air heating mode to keep comfortable feeling with most energy saving;

A.Heat pump with Heating, cooling and domestic hot water function in one solution.
B. One water tank built inside
C. More Operation Mode for heat pump:

D.More advanced timer setting function for heat pump:
1.Single day timer
Three periods on and off setting (Avoid electric peak time to use the cheapest electric and save your bill the most)
2.Weekly timer
Different setting for every day of the week. Totally 42 timer period available for setting

E.Great phone remote control function for heat pump
Control the operation and check the operation mode through simple phone call.

F.Protection function and Error code display for heat pump
1.Pressure, miss phase, wrong phase and high temp protection, water flow protection, antifreeze protection.
2.All error can be checked through controller and error LED light.
G. Historical memory for all heat pump operation for long years.

Mini Chiller SPECIFICATION
Technical data HLR-110D HLR-140D HLR-170D HLR-200D HLR-230D
Floor heating Capacity KW                   11.50                   14.30                   18.00                   21.00                   23.90
Power Input KW                     2.70                     3.70                     4.20                     4.80                     5.40
COP                       4.26                     3.82                     4.28                     4.37                     4.42
Fan coil heating Capacity KW                   10.30                   13.50                   16.60                   19.50                   22.80
Power Input KW                     3.00                     3.80                     4.70                     5.70                     6.80
COP                       3.43                     3.55                     3.53                     3.42                     3.35
Floor cooling Capacity KW                   11.00                   15.00                   17.50                   20.00                   23.00
Power Input KW                     3.10                     4.40                     4.80                     5.30                     6.10
EER                       3.55                     3.41                     3.64                     3.77                     3.77
Fan coil cooling Capacity KW                     8.80                   12.30                   15.50                   17.50                   20.80
Power Input KW                     2.90                     4.00                     4.90                     5.50                     7.10
EER                       3.03                     3.07                     3.16                     3.18                     2.93
Domestic hot water Capacity KW                   10.40                   13.50                   16.50                   19.20                   21.80
Power Input KW                     2.80                     3.80                     4.80                     5.60                     6.60
COP                       3.71                     3.55                     3.44                     3.43                     3.30
Power supply   V/Ph/Hz 230/1/50 380/3/50 380/3/50
Refrigerant     R410A
Compressor Brand     Daikin  Daikin  SANYO  Daikin  SANYO 
Compressor Type     Scroll Scroll  Scroll Scroll  Scroll
Air conditioning tank volume   L 17 20 25 30 30
Dimensiones LXHXD mm 1090X900X450 1090X1000X450 1090X1260X450 1090X1460X450 1090X1460X450
Weight   Kg 110 125 165 190 205
Noise   dB(A) 48 51 50 53 53
Loading QTY  20'SQ/40'HQ PCS 36/82 36/82 18/41 18/41 18/41
               
Floor Heating: 7ºC Outdoor  air / 35ºC Leaving water.  Heating (Fan Coil): 7ºC Outdoor air / 45ºC Leaving water. 
Floor cooling: 35ºC Outdoor air / 16ºC Leaving water..  Cooling (Fan Coil): 35ºC Outdoor  air / 7ºC Leaving water.. 
Domestic Hot Water: 7ºC Outdoor air / 40ºC Water in the tank.   

Send Online Inquiry

Send Online Inquiry

Key Features of Our Heat Pump

  • Original European Technology of Heat Pump
  • High COP Energy Saving with R410a
  • World Top Brand Parts for Heat Pump Life Duration
  • Safety and no Harmful Material Emission
China Palm A/C & Equipment Co.Ltd
Register No: Joint Venture(Guangdong) No #304091
Joint Venture Certificate assigned by government Authenticated and Verified by ZD info Credit Certificate issued by CHC Credit Evaluation Bureau