Heat pump-central air conditioner
Heating Cooling Heat Pump Which can be used for room heating and cooling like central air conditioner.
1. Heat pump with combined Heating, cooling air conditoner and domestic hot water function in one solution for all family requirement in whole year.
2. Built inside fuzzy logic solar combination operation utilize solar for both room heating and domestic hot water, which enable more energy saving than other heat pump.
3. Intelligent automatic operation mode of DHW and room heating for more energy saving during different ambient temp;
4. Intelligent auto defrost, antifreeze protection for low ambient temp operation to minus -15.
5. Real weekly timer-Different setting for every day of the week to fit your life habit the most and save energy. Imaging you will enjoy your weekend in tourism with your sweet family, then the heat pump doesn't need to start at weekend.
6. More energy saving and much more comfortable than normal air conditioner;
7.All error code can be checked through controller display which enable you to solve the problem as soon as possible.
| Model No | Test Condition Air temp/Oulet water temp |
AH-3.5D | AH-4.5H | AH-7H | AH-12H | AH-14H | AH-17H | AH-21H | AH-30H |
| Heating Capcity/Input Power (KW/KW) | At A20/W55ºC | 3.5/0.8 | 4.5/1.02 | 7.05/1.6 | 12/2.5 | 14/3.1 | 17/3.9 | 21/4.9 | 30/6.6 |
| At A7/W35ºC | 2.5/0.6 | 3.8/0.98 | 5.7/1.5 | 9/2.14 | 10.85/2.3 | 15/3.53 | 17/4.1 | 23/5.3 | |
| At A2/W35ºC | 1.8/0.58 | 3.2/0.95 | 4.89/1.45 | 7.6/2 | 8.9/2.27 | 12.5/3.28 | 15.1/3.95 | 20.4/5.2 | |
| Cooling Capcity(KW) | At A35/W18ºC | 2.6/0.72 | 4.1/1.15 | 6.1/1.76 | 9.1 | 11.5 | 15.6 | 19 | 24 |
| Power Supply | 220V/50HZ | 220V or 380V/50HZ | 380V/50HZ | ||||||
| Working Range | ºC | -15 ~ 43 | |||||||
| Max Output water temp | ºC | 60 | |||||||
| Mini water flow(L/H) (Heating- cooling) |
M3/hour | >=0.35 | >=0.6 | >=0.8 | >=1.2 | >=1.8 | >=2.4 | >=3 | >=3.5 |
| Water connection joint | mm | DN20(3/4'') | DN25 | DN32 | |||||
| Packing size | mm | 360*650*790 | 430*695 *1010 | 430*695 *1010 | 415*980 *985 | 465*1085 *1085 | 530*1180 *1170 | 530*1180 *1430 | 530*1180 *1630 |
| Unit size | mm | 254*540*772 | 290*605*850 | 290*605 *850 | 325*860 *870 | 345*960 *970 | 462*1090 *1016 | 462*1090 *1272 | 462*1090 *1475 |
| Protection class | IPx4 | ||||||||
| Anti Shock class | Class 1 | ||||||||
| Refrigerant | R410a | ||||||||
| Noise | dB | 40 | 42 | 45 | 48 | 55 | 56 | 57 | 58 |
| Regulation component | Emersion Expansion valve | ||||||||
| Compressor type | Rotary | Scroll | |||||||
| Heating Cooling heat exchanger | Stainless Steel Plate Heat exchanger | ||||||||
| Loading quantity for 20'/40' | pcs | 138/276 | 90/180 | 90/180 | 64/128 | 54/108 | 42/84 | 21/42 | 21/42 |
Warranty
We provide 1% free spareparts and 1 year warranty for factory fault since shipment arrival.
We will send the spare parts by courrier method after confirm it is due to factory fault.
We don't cover the cost for failure from shipment, wrong installation and incorrect usage. Of course we can provide parts by customer's cost after warranty period.
Customer Service
We can provide free heat pump installation consultation.
We can provide after sales service, technical assistant.
We can help to purchase other parts related to heat pumps or recommand reliable suppliers directly.
Shipping
For heat pump samples delivery, after packing with export class thick 5 layers paper box, we will pack heat pumps with poly wood case to avoid any damage as shown attached.
There are two ways to delivery the samples.
For sea freight, we will keep the refrigerant inside of the heat pump.
For air freight cargo, due to the air line regulation, we need to drain out the refrigerant. So you need to charge the refrigerant if you find the heat pump cannot start.
For all products above 50kg, we will fix it on a good structured wood or polywood pallet as shown below.


For Container delivery, we use only export thick 5 layer paper box. After carefully loading, we will take pictures before close the container door to assure everything is ok.

If by sea, normally we export at EXW, FOB or CFR terms, we only delivery goods to the destination sea port. The customers need to cover cost for their import duty and cost. Of course the customers can use our forwarder agent to help you to clear the customs.
We can provide all necessary document such as Form A, certificate of origin, Bill of lading, Invoice and packing list.
Normally it will take about 30 days by sea and one week by air.
Triaqua Monobloc heat pump-one inner water tank with expansion tank
1.Triaqua Monobloc heat pump-one inner water tank with expansion tank for easy installation.
2.Heating Cooling and domestic hot water multifunctional Heat Pump available for 11KW,14KW,17KW,20KW,23KW
3. Intelligent automatic operation mode of DHW and room heating for more energy saving during different ambient temp;
4. Intelligent auto defrost, antifreezeprotection for low ambient temp operation to minus -15.
5. Real weekly timer-Different setting for every dayof the week to fit your life habit the most and save energy. Imaging you will enjoy your weekend in tourism with your sweet family, then the heat pump doesn't need to start at weekend.
6.All error code can be checked through controller display which enable you to solve the problem as soon as possible.
| Technical data | HLR-110D | HLR-140D | HLR-170D | HLR-200D | HLR-230D | ||
| Floor heating | Capacity | KW | 11.1 | 14.52 | 18.00 | 21.00 | 23.90 |
| Power Input | KW | 2.64 | 3.30 | 4.21 | 4.81 | 5.41 | |
| COP | 4.2 | 4.40 | 4.28 | 4.37 | 4.42 | ||
| Floor cooling | Capacity | KW | 12.1 | 15.00 | 17.50 | 20.00 | 23.00 |
| Power Input | KW | 3.1 | 3.94 | 4.56 | 5.17 | 5.88 | |
| EER | 3.9 | 3.81 | 3.84 | 3.87 | 3.91 | ||
| Domestic hot water | Capacity | KW | 11 | 14.08 | 16.50 | 19.20 | 21.80 |
| Power Input | KW | 2.89 | 3.75 | 4.33 | 5.07 | 5.74 | |
| COP | 3.8 | 3.75 | 3.81 | 3.79 | 3.80 | ||
| Power supply | V/Ph/Hz | 230/1/50 | 380/3/50 | ||||
| Refrigerant | R410 | ||||||
| Compressor Type | Scroll | Scroll | Scroll | Scroll | Scroll | ||
| Air conditioning tank volume | L | 20 | 20 | 25 | 30 | 30 | |
| Dimensiones | LXHXD | mm | 1090X1000X450 | 1090X1260X450 | 1090X1460X450 | ||
| Weight | Kg | 110 | 125 | 165 | 190 | 205 | |
| Noise | dB(A) | 48 | 51 | 50 | 53 | 53 | |
| Loading QTY 20'SQ/40'HQ | PCS | 36/82 | 36/82 | 18/41 | 18/41 | 18/41 | |
TEST UNDER European heat pump standard EN14511 STANDARD CONDITION:
Floor Heating: 7°C Outdoor air / 35°C Leaving water.
Floor cooling: 35°C Outdoor air / 18°C Leaving water..
Domestic Hot Water: 7°C Outdoor air / 40°C Water in the tank.
combined-heating-cooling-and-hot-water-heat-pump-17kw
Heating Cooling Heat Pump available for 2KW,3.5KW,4.5KW,7KW,9KW,11KW,14KW,17KW,20KW,22KW,30,40KW
1. Heat pump with combined Heating, cooling and domestic hot waterfunction in one solution for all family requirement in whole year.
2. Built inside fuzzy logic solar combination operation utilize solar for both room heating and domestic hot water, which enable more energy saving than other heat pump.
3. Intelligent automatic operation modeof DHW and room heating for more energy saving during different ambient temp;
4. Intelligent auto defrost, antifreezeprotection for low ambient temp operation to minus -15.
5. Real weekly timer-Different setting for every dayof the week to fit your life habit the most and save energy. Imaging you will enjoy your weekend in tourism with your sweet family, then the heat pump doesn't need to start at weekend.
6. More energy saving and much more comfortable than normal air conditioner;
7.All error code can be checked through controller display which enable you to solve the problem as soon as possible.
| Model No | Test Condition Air temp/Oulet water temp |
AH-3.5H | AH-4.5H | AH-7H | AH-12H | AH-14H | AH-17H | AH-21H | AH-30H |
| Heating Capcity/Input Power (KW/KW) | At A20/55ºC | 3.5/0.8 | 4.5/1.02 | 7.05/1.6 | 12/2.5 | 14/3.1 | 17/3.9 | 21/4.9 | 30/6.6 |
| At A7/35ºC | 2.5/0.6 | 3.8/0.98 | 5.7/1.5 | 9/2.14 | 10.85/2.3 | 15/3.53 | 17/4.1 | 23/5.3 | |
| At A2/35ºC | 1.8/0.58 | 3.2/0.95 | 4.89/1.45 | 7.6/2 | 8.9/2.27 | 12.5/3.28 | 15.1/3.95 | 20.4/5.2 | |
| Cooling Capcity(KW) | At A35/18ºC | 2.6/0.72 | 4.1/1.15 | 6.1/1.76 | 9.1 | 11.5 | 15.6 | 19 | 24 |
| Power Supply | 220V/50HZ | 220V or 380V/50HZ | 380V/50HZ | ||||||
| Working Range | ºC | -15 ~ 43 | |||||||
| Max Output water temp | ºC | 60 | |||||||
| Mini water flow(L/H) (Heating- cooling) |
M3/hour | >=0.35 | >=0.6 | >=0.8 | >=1.2 | >=1.8 | >=2.4 | >=3 | >=3.5 |
| Water connection joint | mm | DN20(3/4'') | DN25 | DN32 | |||||
| Packing size | mm | 360*650*790 | 430*695 *1010 | 430*695 *1010 | 415*980 *985 | 465*1085 *1085 | 530*1180 *1170 | 530*1180 *1430 | 530*1180 *1630 |
| Unit size | mm | 254*540*772 | 290*605*850 | 290*605 *850 | 325*860 *870 | 345*960 *970 | 462*1090 *1016 | 462*1090 *1272 | 462*1090 *1475 |
| Protection class | IPx4 | ||||||||
| Anti Shock class | Class 1 | ||||||||
| Refrigerant | R410a | ||||||||
| Noise | dB | 40 | 42 | 45 | 48 | 55 | 56 | 57 | 58 |
| Regulation component | Emersion Expansion valve | ||||||||
| Compressor type | Rotary | Scroll | |||||||
| Heating Cooling heat exchanger | Stainless Steel Plate Heat exchanger | ||||||||
| Loading quantity for 20'/40' | pcs | 138/276 | 90/180 | 90/180 | 64/128 | 54/108 | 42/84 | 21/42 | 21/42 |
Two Years Warranty !
We provide 1% free spareparts with containered order and 2 year warranty of main parts for factory fault since shipment arrival.
We will send the spare parts by courrier method after confirm it is due to factory fault.
We don't cover the cost for failure from shipment, wrong installation and incorrect usage. Of course we can provide parts by customer's cost after warranty period.
Customer Service
We can provide free heat pump installation consultation.
We can provide after sales service, technical assistant.
We can help to purchase other parts related to heat pumps or recommand reliable suppliers directly.
Shipping
For heat pump samples delivery, after packing with export class thick 5 layers paper box, we will pack heat pumps with poly wood case to avoid any damage as shown attached.
There are two ways to delivery the samples.
For sea freight, we will keep the refrigerant inside of the heat pump.
For air freight cargo, due to the air line regulation, we need to drain out the refrigerant. So you need to charge the refrigerant if you find the heat pump cannot start.
For all products above 50kg, we will fix it on a good structured wood or polywood pallet as shown below.

For Container delivery, we use only export thick 5 layer paper box. After carefully loading, we will take pictures before close the container door to assure everything is ok.

If by sea, normally we export at EXW, FOB or CFR terms, we only delivery goods to the destination sea port. The customers need to cover cost for their import duty and cost. Of course the customers can use our forwarder agent to help you to clear the customs.
We can provide all necessary document such as Form A, certificate of origin, Bill of lading, Invoice and packing list.
Normally it will take about 30 days by sea and one week by air.
Combined heating cooling and hot water heat pump 2kw-30kw
Heating Cooling Heat Pump available for 2KW,3.5KW,4.5KW,7KW,9KW,11KW,15KW,17KW,20KW,22KW,30,40KW
1. Heat pump with combined Heating, cooling and domestic hot water function in one solution for all family requirement in whole year.
2. Built inside fuzzy logic solar combination operation utilize solar for both room heating and domestic hot water, which enable more energy saving than other heat pump.
3. Intelligent automatic operation mode of DHW and room heating for more energy saving during different ambient temp;
4. Intelligent auto defrost, antifreeze protection for low ambient temp operation to minus -15.
5. Real weekly timer-Different setting for every day of the week to fit your life habit the most and save energy. Imaging you will enjoy your weekend in tourism with your sweet family, then the heat pump doesn't need to start at weekend.
6. More energy saving and much more comfortable than normal air conditioner;
7.All error code can be checked through controller display which enable you to solve the problem as soon as possible.
Two Years Warranty !
We provide 1% free spareparts with containered order and 2 year warranty of main parts for factory fault since shipment arrival.
We will send the spare parts by courrier method after confirm it is due to factory fault.
We don't cover the cost for failure from shipment, wrong installation and incorrect usage. Of course we can provide parts by customer's cost after warranty period.
Customer Service
We can provide free heat pump installation consultation.
We can provide after sales service, technical assistant.
We can help to purchase other parts related to heat pumps or recommand reliable suppliers directly.
Shipping
For heat pump samples delivery, after packing with export class thick 5 layers paper box, we will pack heat pumps with poly wood case to avoid any damage as shown attached.
There are two ways to delivery the samples.
For sea freight, we will keep the refrigerant inside of the heat pump.
For air freight cargo, due to the air line regulation, we need to drain out the refrigerant. So you need to charge the refrigerant if you find the heat pump cannot start.
For all products above 50kg, we will fix it on a good structured wood or polywood pallet as shown below.


For Container delivery, we use only export thick 5 layer paper box. After carefully loading, we will take pictures before close the container door to assure everything is ok.

If by sea, normally we export at EXW, FOB or CFR terms, we only delivery goods to the destination sea port. The customers need to cover cost for their import duty and cost. Of course the customers can use our forwarder agent to help you to clear the customs.
We can provide all necessary document such as Form A, certificate of origin, Bill of lading, Invoice and packing list.
Normally it will take about 30 days by sea and one week by air.
Heat recovery heat pump 7kw-9kw

It means 1KW electricity input equal 7KW output.

Central Heating+Central Cooling+Domestic hot water with heat recovery Heat Pump available for 7KW,10KW,14KW,17KW,20KW,25KW,30KW,40KW,50KW,60KW
Product Function:
Central Heating, central cooling and domestic hot water function in one solution.
Provide free hot water when cooling
6.Advanced timer setting function for heat pump:
Single day timer and Weekly timer are both available.Can be different setting for every day of the whole week.
7.Phone remote control function for heat pump is optional
Control the operation and check the operation mode through simple phone call.
8. Historical record for all heat pump operation for long years.
Heat recovery heat pump technical data:
| Model | 7K | 10K | 14K | 17K | 20K | 25K | 30K | 40K | 50K | 60K |
| Cooling Capcity(KW) | 5.8 | 8.5 | 11.5 | 13.5 | 15 | 20 | 24 | 32 | 41 | 50 |
| Heating Capcity(KW) | 7 | 10 | 14 | 17 | 20 | 25 | 30 | 40 | 50 | 60 |
| Input power(KW) | 2 | 2.8 | 4.3 | 4.8 | 5.2 | 6.5 | 7.9 | 10.5 | 13.2 | 15.8 |
| Cooling+DHW COP | 7 | |||||||||
| Power Supply | 220V/50HZ | 380V/50 | ||||||||
| Max Output water temp | 60ºC | |||||||||
| Mini water flow(L/H)(DHW) | 1200 | 1800 | 2400 | 3000 | 3500 | 4300 | 5200 | 6800 | 8600 | 10000 |
| Mini water flow(L/H)(Heating and cooling) | 1200 | 1800 | 2400 | 3000 | 3500 | 4300 | 5200 | 6800 | 8600 | 10000 |
| Water connection joint(mm) | DN25 | DN32 | DN50 | |||||||
| Packing size(mm) | 415*980*985 | 465*1085*1085 | 530*1180*1170 | 530*1180*1430 | 530*1180*1630 | 1070*1680*1990 | ||||
| Unit size(mm) | 325*860*870 | 345*960*970 | 462*1090*1016 | 462*1090*1271 | 462*1090*1473 | 970*1580*1890 | ||||
| Protection class | IPx4 | |||||||||
| Anti Shock class | Class 1 | |||||||||
| Refrigerant | R410a | |||||||||
| Regulation component | Emersion Expansion valve | |||||||||
| Compressor type | Rotary | Scroll | Scroll(Dual compressor) | |||||||
| DHW heat exchanger | Pipe in Pipe Heat exchanger | Copper pipe+ aluminum fins | Copper pipe+ aluminum fins | |||||||
| Heating Cooling heat exchanger | Pipe in Pipe Heat exchanger | Plate heat exchanger | Plate heat exchanger or pipe shell heat exchanger | |||||||
DC inverter air source heat pump 11KW-product-180
Heating and Cooling DC Inverter air source Heat Pump with R410a , 6KW,8KW,10KW
Higer efficiency than normal air source heat pump.
Main Characters:
1. Heating and Cooling function
2. Extrimly energy saving, super cost saving with R410a gas inside.
3. Installation is easy and flexible..
4. Can be connected with solar water heater system.
5. All water access parts are stainless steel to keep safe, healthy and non-pollution
Quality for reliability and save maintenance cost:
Our parts are always choosend with the top brand in the world
Heat exchanger: SWEP brand plate heat exchanger from Sweden.
Heat expansion valve: Emerson brand
Four way valve: Saginomiya brand of Japan
The above parts enable our heat pump to be trouble free products.
Heat-Recovery-Heat-Pump-for-Heat-Cool-Hot-Water-product-178

Thanks to our Epoch-Making new technolgy, our new heat recovery heat pump efficency (COP) is up to 7.0 when central cooling + hot water; COP is up to 5.0 when central heating+hot water.
It means 1KW electricity input equal 7KW output.

Palm Central Heating+Central Cooling+Domestic hot water with heat recovery Heat Pump available for 7KW,10KW,14KW,17KW,20KW,25KW,30KW,40KW,50KW,60KW
Product Function:
Central Heating, central cooling and domestic hot water function in one solution.
Provide free hot water when cooling
4. Environment friendly: R410a refrigerant, no pollution, no waste discharge;
5. Economic: The running cost of palm heat pump can be 85% less than that of a traditional gas boiler heating system;
6.Advanced timer setting function for heat pump :
Single day timer and Weekly timer are both available.Can be different setting for every day of the whole week.
Heat recovery heat pump technical data:
| Model | AH-7R-410 | AH-9R-410 | AH-15R-410 | AH-17R-410 | AH-20R | 25K | 30K | 40K | 50K | 60K |
| Cooling Capcity(KW) | 7.8 | 9.5 | 14.5 | 17.5 | 21 | 26 | 31 | 40 | 51 | 60 |
| Heating Capcity(KW) | 7 | 9 | 14 | 17 | 20 | 25 | 30 | 40 | 50 | 60 |
| Input power(KW) | 2 | 2.3 | 4.3 | 4.8 | 5.2 | 6.5 | 7.9 | 10.5 | 13.2 | 15.8 |
| Cooling+DHW COP | 7 | |||||||||
| Power Supply | 220V/50HZ | 380V/50 | ||||||||
| Max Output water temp | 60ºC | |||||||||
| Mini water flow(L/H)(DHW) | 1200 | 1800 | 2400 | 3000 | 3500 | 4300 | 5200 | 6800 | 8600 | 10000 |
| Mini water flow(L/H)(Heating and cooling) | 1200 | 1800 | 2400 | 3000 | 3500 | 4300 | 5200 | 6800 | 8600 | 10000 |
| Water connection joint(mm) | DN25 | DN32 | DN50 | |||||||
| Packing size(mm) | 415*980*985 | 465*1085*1085 | 530*1180*1170 | 530*1180*1430 | 530*1180*1630 | 1070*1680*1990 | ||||
| Unit size(mm) | 325*860*870 | 345*960*970 | 462*1090*1016 | 462*1090*1271 | 462*1090*1473 | 970*1580*1890 | ||||
| Protection class | IPx4 | |||||||||
| Anti Shock class | Class 1 | |||||||||
| Refrigerant | R410a | |||||||||
| Regulation component | Emersion Expansion valve | |||||||||
| Compressor type | Rotary | Scroll | Scroll(Dual compressor) | |||||||
| DHW heat exchanger | Copper pipe+ aluminum fins | Copper pipe+ aluminum fins | Copper pipe+ aluminum fins | |||||||
| Heating Cooling heat exchanger | Plate heat exchanger | Plate heat exchanger | Plate heat exchanger or pipe shell heat exchanger | |||||||
Reliable Quality for saving maintenance cost:
Our parts are always choosend with the top brand in the world
Heat exchanger: SU316 stainless plate heat exchanger.
The compressor: Daikin, Hitachi,Toshiba,Sanyo brand
Heat expansion valve: Emerson brand
Optional water pump: Wilo brand from Germany
Four way valve: Saginomiya brand of Japan
The above parts enable our heat pump to be trouble free products.
Warranty
We provide 1% free spareparts and 1 year warranty for factory fault since shipment arrival.
We will send the spare parts by courrier method after confirm it is due to factory fault.
We don't cover the cost for failure from shipment, wrong installation and incorrect usage. Of course we can provide parts by customer's cost after warranty period.
Customer Service
We can provide free heat pump installation consultation.
We can help to purchase other parts related to heat pumps or recommand reliable suppliers directly.
Shipping
For heat pump samples delivery, after packing with export class thick 5 layers paper box, we will pack heat pumps with poly wood case to avoid any damage as shown attached.
There are two ways to delivery the samples.
For sea freight, we will keep the refrigerant inside of the heat pump.
For air freight cargo, due to the air line regulation, we need to drain out the refrigerant. So you need to charge the refrigerant if you find the heat pump cannot start.
For all products above 50kg, we will fix it on a good structured wood or polywood pallet as shown below.

For Container delivery, we use only export thick 5 layer paper box. After carefully loading, we will take pictures before close the container door to assure everything is ok.

If by sea, normally we export at EXW, FOB or CFR terms, we only delivery goods to the destination sea port. The customers need to cover cost for their import duty and cost. Of course the customers can use our forwarder agent to help you to clear the customs.
We can provide all necessary document such as Form A, certificate of origin, Bill of lading, Invoice and packing list.
Normally it will take about 30 days by sea and one week by air.
Air to water heat pump 3.5KW 4KW 6kw to 68KW-product-157


|
Air to Water Heat Pumps Specification
|
|||||||||||
|
Models (1)
|
AH-35H/N1
|
COP
|
AH-35H/N1a
|
COP
|
AH(P)-55H/N1
|
COP
|
AH(P)-80H/N1
|
COP
|
AH-110H/SN1
|
COP
|
|
|
Heating capacity(2) /Power input (KW)
|
at A20/W35ºC (3)
|
4.6/1.09
|
4.22
|
4.6/1.15
|
4
|
7.04/1.68
|
4.19
|
10.62/2.43
|
4.37
|
14.41/3.38
|
4.26
|
|
at A20/W50ºC (3)
|
4.5/1.4
|
3.2
|
4.5/1.4
|
3.21
|
6.8/2.15
|
3.16
|
10.25/3.12
|
3.29
|
14.0/4.29
|
3.26
|
|
|
at A15/W50ºC (3)
|
4.1/1.35
|
3.0
|
4.1/1.35
|
3.04
|
6.25/2.07
|
3.02
|
9.34/3.0
|
3.11
|
12.76/4.13
|
3.09
|
|
|
at A7/W35ºC (3)
|
3.6/0.98
|
3.7
|
3.6/0.98
|
3.67
|
5.5/1.5
|
3.67
|
8.2/2.18
|
3.76
|
11.2/3.0
|
3.73
|
|
|
at A7/W45ºC (3)
|
3.58/1.15
|
3.1
|
3.58/1.15
|
3.11
|
5.47/1.76
|
3.11
|
8.15/2.56
|
3.18
|
11.14/3.52
|
3.16
|
|
|
at A7/W50ºC (3)
|
3.4/1.26
|
2.7
|
3.4/1.26
|
2.7
|
5.24/1.92
|
2.73
|
7.8/2.76
|
2.83
|
10.8/3.8
|
2.84
|
|
|
at A2/W35ºC (3)
|
3.2/0.95
|
3.4
|
3.2/0.95
|
3.37
|
4.89/1.45
|
3.37
|
7.29/2.11
|
3.45
|
9.96/2.91
|
3.42
|
|
|
at A2/W50ºC (3)
|
3.05/1.23
|
2.5
|
3.05/1.23
|
2.48
|
4.66/1.88
|
2.48
|
6.95/2.74
|
2.54
|
9.49/3.77
|
2.52
|
|
|
at A0/W45ºC (3)
|
2.85/1.12
|
2.5
|
2.85/1.12
|
2.54
|
4.35/1.71
|
2.54
|
6.49/2.49
|
2.61
|
8.87/3.43
|
2.59
|
|
|
at A-7/W45ºC (3)
|
2.2/1.1
|
2.0
|
2.2/1.1
|
2
|
3.36/1.68
|
2
|
5.01/2.45
|
2.04
|
6.84/3.37
|
2.03
|
|
|
at A-7/W50ºC (3)
|
2.15/1.18
|
1.8
|
2.15/1.18
|
1.82
|
3.28/1.81
|
1.81
|
4.9/2.62
|
1.87
|
6.69/3.61
|
1.85
|
|
|
colling capacity/Power input(KW)
|
at A35/W7ºC (3)
|
3.3/1.15
|
2.9
|
3.3/1.15
|
2.9 |
5.1/1.76
|
2.9
|
7.6/2.56
|
2.97
|
10.5/3.52
|
2.98
|
|
Max.power input (KW)
|
1.8
|
1.8
|
2.6
|
3.8
|
5.5
|
||||||
|
Max.currentt (A)
|
8.2
|
8.2
|
12.5
|
17.4
|
9
|
||||||
|
Electric supply
|
230V-50Hz
|
400V-3N-50Hz
|
|||||||||
|
Max.water temperature (ºC)
|
60
|
||||||||||
|
Running temperature range (ºC)
|
-15~43
|
||||||||||
|
Refrigerant circuit
|
Refrigerant
|
R407C
|
|||||||||
|
compressor(s)
|
Rotary
|
Rotary
|
Rotary
|
Rotary
|
Scroll
|
||||||
|
Heat exchange
|
High efficiency fin-tube heat exchanger
|
||||||||||
|
Fan motor (W)
|
35
|
80
|
80
|
150
|
250
|
||||||
|
Air flow (m3/h)
|
2000
|
3000
|
3000
|
4500
|
6500
|
||||||
|
Water circuit
|
Heat exchanger
|
Stainless steel plate heat exchanger
|
|||||||||
|
In/Out pipe
|
DN20(3/4'')
|
DN20(3/4'')
|
DN20(3/4'')
|
DN25(1'')
|
DN25(1'')
|
||||||
|
Water flow (m3/h)
|
>=0.6
|
>=0.6
|
>=0.8
|
>=1.2
|
>=1.6
|
||||||
|
permitted pressure
|
=<0.8MPa
|
||||||||||
|
Unit dimensions WxHxD (mm)
|
772x540x254
|
850x605x290
|
850x605x290
|
850x850x310
|
970x960x360
|
||||||
|
Pacage dimensions WxHxD (mm)
|
790x650x360
|
1010x695x430
|
1010x695x430
|
1010x875x430
|
1100x1100x440
|
||||||
|
Net weight (Kg)
|
45
|
52
|
65
|
81
|
110
|
||||||
|
Gross weight (Kg)
|
47
|
57
|
68
|
86
|
118
|
||||||
|
Noise level (dB(A))
|
51
|
51
|
52
|
54
|
56
|
||||||
| Electric heater(optional) (4) (KW) | |||||||||||
|
Air to Water Heat Pumps Specification
|
||||||||||
|
Models (1)
|
AH(P)-160H/SN1
|
COP
|
AH(P)-220H/SN1
|
COP
|
AH(DP)-280H/SN1
|
COP
|
AH(DP)-560H/SN1
|
COP
|
AH(DP)-680H/SN1
|
|
|
Heating capacity(2) /Power input (KW)
|
at A20/W35ºC (3)
|
21.51/5.12
|
4.2
|
28.7/6.9
|
4.16
|
36.5/9.1
|
4.01
|
71.68/17.72
|
4.05
|
86.95/21.99
|
|
at A20/W50ºC (3)
|
20.8/6.5
|
3.2
|
28.0/8.58
|
3.26
|
35.4/11.15
|
3.19
|
70/21.66
|
3.24
|
85/26.88
|
|
|
at A15/W50ºC (3)
|
18.79/6.34
|
2.96
|
25.6/8.25
|
3.1
|
32.2/10.7
|
3.01
|
63.78/20.87
|
3.07
|
77.44/25.9
|
|
|
at A7/W35ºC (3)
|
16.5/4.6
|
3.59
|
22.4/6.0
|
3.73
|
28.3/7.8
|
3.63
|
56/15.15
|
3.71
|
68/18.8
|
|
|
at A7/W45ºC (3)
|
16.41/5.4
|
3.04
|
22.28/7.04
|
3.16
|
28.14/9.15
|
3.08
|
55.69/17.78
|
3.15
|
67.62/22.06
|
|
|
at A7/W50ºC (3)
|
15.7/5.9
|
2.66
|
21.3/7.7
|
2.77
|
27.2/10
|
2.72
|
52.89/19.48
|
2.73
|
64.22/24.17
|
|
|
at A2/W35ºC (3)
|
14.67/4.46
|
3.29
|
19.91/5.82
|
3.42
|
25.16/7.56
|
3.33
|
49.78/14.69
|
3.41
|
60.44/18.22
|
|
|
at A2/W50ºC (3)
|
13.98/5.77
|
2.42
|
18.98/7.53
|
2.52
|
23.98/9.79
|
2.45
|
47.44/19.01
|
2.5
|
57.61/23.6
|
|
|
at A0/W45ºC (3)
|
13.06/5.26
|
2.48
|
17.73/6.86
|
2.58
|
22.4/8.91
|
2.51
|
44.33/17.31
|
2.56
|
53.83/21.49
|
|
|
at A-7/W45ºC (3)
|
10.08/5.16
|
1.95
|
13.69/6.73
|
2.03
|
17.29/8.76
|
1.97
|
34.22/17.01
|
2.01
|
41.56/21.10
|
|
|
at A-7/W50ºC (3)
|
9.85/5.54
|
1.78
|
13.38/7.22
|
1.85
|
16.9/9.39
|
1.8
|
33.44/18.24
|
1.84
|
40.61/22.64
|
|
|
colling capacity/Power input(KW)
|
at A35/W7ºC (3)
|
15/5.4
|
2.78
|
20/7.04
|
2.84
|
26.3/9.15
|
2.87
|
52.5/17.1878
|
3.07
|
66/22.06
|
|
Max.power input (KW)
|
8
|
10.4
|
13.5
|
26.3
|
32.7
|
|||||
|
Max.currentt (A)
|
13
|
17
|
22
|
42.8
|
53.1
|
|||||
|
Electric supply
|
400V-3N-50Hz
|
|||||||||
|
Max.water temperature (ºC)
|
60
|
|||||||||
|
Running temperature range (ºC)
|
-15~43
|
|||||||||
|
Refrigerant circuit
|
Refrigerant
|
R407C
|
||||||||
|
compressor(s)
|
Scroll
|
Scroll
|
2xScroll
|
4xScroll
|
4xScroll
|
|||||
|
Heat exchange
|
High efficiency fin-tube heat exchanger
|
|||||||||
|
Fan motor (W)
|
150x2
|
250x2
|
700
|
700x2
|
850x2
|
|||||
|
Air flow (m3/h)
|
9000
|
12000
|
14500
|
28000
|
32000
|
|||||
|
Water circuit
|
Heat exchanger
|
Stainless steel plate heat exchanger
|
Double pipe heat exchangr
|
|||||||
|
In/Out pipe
|
DN32(1-1/4")
|
DN32(1-1/4")
|
DN40(1-1/2")
|
DN50(2")
|
DN50(2")
|
|||||
|
Water flow (m3/h)
|
>=2.2
|
>=3.0
|
>=3.5
|
>=7.0
|
>=9.0
|
|||||
|
permitted pressure
|
=<0.8MPa
|
|||||||||
|
Unit dimensions WxHxD (mm)
|
970x1258x380
|
970x1500x360
|
1265x1760x1020
|
1950x1930x1100
|
||||||
|
Pacage dimensions WxHxD (mm)
|
1070x1410x450
|
1100x1640x440
|
1415x1890x1200
|
2200x2200x1350
|
||||||
|
Net weight (Kg)
|
140
|
180
|
300
|
560
|
620
|
|||||
|
Gross weight (Kg)
|
150
|
195
|
325
|
600
|
660
|
|||||
|
Noise level (dB(A))
|
56
|
57
|
59
|
61
|
62
|
|||||
|
Electric heater(optional) (4) (KW)
|
9
|
20
|
5
|
|||||||
Note:
(1) The circulation pump and the auxiliary electric heater is optional.D:with inside auxiliary electric heater; P:with inside circulation.
(2)The data of stable running condition(when defrosting,the average heating capacity reduces about 10% compare to corresponding data)
(3)Surrounding air temperature/outlet water temperature
(4)The electric heater must be equipped outside for the models fom AH-35H/N1 to AH(P)-220H/SN1.AHP-280 and AHP-350 electric heater can be installed inside of the unit.
Product Description
Our heat pump is a new generation heat pump prduct developed with the most advanced heating technologies. The heat pump utilizeds the energy from surrounding air and converts it to the hot water for house air conditioning heating cooling and domestic hot water supply. The whole range of this heat pump is strictly tested with our European partners to make sure the best quality for European market. Especially for super low temperature area. The working abient is -15 degree to 45 degree and keep supply of warm water from 35 degree to 60 degree.
We select the best well known components for our heat pump such as Copeland compressor, Siemens, Danfoss, Wilo. It provide the most reliability to our customers.
Striking characters distinguish from other products
1.High efficiency and energy saving
2.Environmental friendly refrigerant
3.Keep working in super low temperature
4.Using step fan motor to make the accurate control
5.Water flow protection, pressure prtection, temp protection keep the the system safety.
Other characters
1.Stainless steel plate heat exchanger with maximum pressure 40 bar
2.100% stainless water circuit to keep water clean
3.Microprocessor control and error alarm and display
4.Electric protection class IPX4
5.Compact design for good looking, easy installation and maintenance
Heating Cooling Hot Water MonoBloc HeatPump 14KW-product-176

Heating Cooling heat pump available for 11KW,14KW,17KW,20KW,23KW
B. One water tank built inside
C. More Operation Mode for heat pump:
DHW automatic operation mode for more energy saving;
Air heating automatic operation mode to achieve more energy saving;
Great economical air heating mode to keep comfortable feeling with most energy saving;
D.More advanced timer setting function for heat pump:
1.Single day timer
Three periods on and off setting (Avoid electric peak time to use the cheapest electric and save your bill the most)
2.Weekly timer
Different setting for every day of the week. Totally 42 timer period available for setting
E.Great phone remote control function for heat pump
Control the operation and check the operation mode through simple phone call.
F.Protection function and Error code display for heat pump
1.Pressure, miss phase, wrong phase and high temp protection, water flow protection, antifreeze protection.
2.All error can be checked through controller and error LED light.
G. Historical memory for all heat pump operation for long years.
| Mini Chiller SPECIFICATION | |||||||
| Technical data | HLR-110D | HLR-140D | HLR-170D | HLR-200D | HLR-230D | ||
| Floor heating | Capacity | KW | 11.50 | 14.30 | 18.00 | 21.00 | 23.90 |
| Power Input | KW | 2.70 | 3.70 | 4.20 | 4.80 | 5.40 | |
| COP | 4.26 | 3.82 | 4.28 | 4.37 | 4.42 | ||
| Fan coil heating | Capacity | KW | 10.30 | 13.50 | 16.60 | 19.50 | 22.80 |
| Power Input | KW | 3.00 | 3.80 | 4.70 | 5.70 | 6.80 | |
| COP | 3.43 | 3.55 | 3.53 | 3.42 | 3.35 | ||
| Floor cooling | Capacity | KW | 11.00 | 15.00 | 17.50 | 20.00 | 23.00 |
| Power Input | KW | 3.10 | 4.40 | 4.80 | 5.30 | 6.10 | |
| EER | 3.55 | 3.41 | 3.64 | 3.77 | 3.77 | ||
| Fan coil cooling | Capacity | KW | 8.80 | 12.30 | 15.50 | 17.50 | 20.80 |
| Power Input | KW | 2.90 | 4.00 | 4.90 | 5.50 | 7.10 | |
| EER | 3.03 | 3.07 | 3.16 | 3.18 | 2.93 | ||
| Domestic hot water | Capacity | KW | 10.40 | 13.50 | 16.50 | 19.20 | 21.80 |
| Power Input | KW | 2.80 | 3.80 | 4.80 | 5.60 | 6.60 | |
| COP | 3.71 | 3.55 | 3.44 | 3.43 | 3.30 | ||
| Power supply | V/Ph/Hz | 230/1/50 | 380/3/50 | 380/3/50 | |||
| Refrigerant | R410A | ||||||
| Compressor Brand | Daikin | Daikin | SANYO | Daikin | SANYO | ||
| Compressor Type | Scroll | Scroll | Scroll | Scroll | Scroll | ||
| Air conditioning tank volume | L | 17 | 20 | 25 | 30 | 30 | |
| Dimensiones | LXHXD | mm | 1090X900X450 | 1090X1000X450 | 1090X1260X450 | 1090X1460X450 | 1090X1460X450 |
| Weight | Kg | 110 | 125 | 165 | 190 | 205 | |
| Noise | dB(A) | 48 | 51 | 50 | 53 | 53 | |
| Loading QTY 20'SQ/40'HQ | PCS | 36/82 | 36/82 | 18/41 | 18/41 | 18/41 | |
| Floor Heating: 7ºC Outdoor air / 35ºC Leaving water. | Heating (Fan Coil): 7ºC Outdoor air / 45ºC Leaving water. | ||||||
| Floor cooling: 35ºC Outdoor air / 16ºC Leaving water.. | Cooling (Fan Coil): 35ºC Outdoor air / 7ºC Leaving water.. | ||||||
| Domestic Hot Water: 7ºC Outdoor air / 40ºC Water in the tank. | |||||||
Heat Pump Mini Chiller Heating-Cooling-DHW-17-23KW-product-158

Heating Cooling Heat Pump available for 11KW,14KW,17KW,20KW,23KWDHW automatic operation mode for more energy saving;
Air heating automatic operation mode to achieve more energy saving;
Great economical air heating mode to keep comfortable feeling with most energy saving;
A.Heat pump with Heating, cooling and domestic hot water function in one solution.
B. One water tank built inside
C. More Operation Mode for heat pump:
D.More advanced timer setting function for heat pump:
1.Single day timer
Three periods on and off setting (Avoid electric peak time to use the cheapest electric and save your bill the most)
2.Weekly timer
Different setting for every day of the week. Totally 42 timer period available for setting
E.Great phone remote control function for heat pump
Control the operation and check the operation mode through simple phone call.
F.Protection function and Error code display for heat pump
1.Pressure, miss phase, wrong phase and high temp protection, water flow protection, antifreeze protection.
2.All error can be checked through controller and error LED light.
G. Historical memory for all heat pump operation for long years.
| Mini Chiller SPECIFICATION | |||||||
| Technical data | HLR-110D | HLR-140D | HLR-170D | HLR-200D | HLR-230D | ||
| Floor heating | Capacity | KW | 11.50 | 14.30 | 18.00 | 21.00 | 23.90 |
| Power Input | KW | 2.70 | 3.70 | 4.20 | 4.80 | 5.40 | |
| COP | 4.26 | 3.82 | 4.28 | 4.37 | 4.42 | ||
| Fan coil heating | Capacity | KW | 10.30 | 13.50 | 16.60 | 19.50 | 22.80 |
| Power Input | KW | 3.00 | 3.80 | 4.70 | 5.70 | 6.80 | |
| COP | 3.43 | 3.55 | 3.53 | 3.42 | 3.35 | ||
| Floor cooling | Capacity | KW | 11.00 | 15.00 | 17.50 | 20.00 | 23.00 |
| Power Input | KW | 3.10 | 4.40 | 4.80 | 5.30 | 6.10 | |
| EER | 3.55 | 3.41 | 3.64 | 3.77 | 3.77 | ||
| Fan coil cooling | Capacity | KW | 8.80 | 12.30 | 15.50 | 17.50 | 20.80 |
| Power Input | KW | 2.90 | 4.00 | 4.90 | 5.50 | 7.10 | |
| EER | 3.03 | 3.07 | 3.16 | 3.18 | 2.93 | ||
| Domestic hot water | Capacity | KW | 10.40 | 13.50 | 16.50 | 19.20 | 21.80 |
| Power Input | KW | 2.80 | 3.80 | 4.80 | 5.60 | 6.60 | |
| COP | 3.71 | 3.55 | 3.44 | 3.43 | 3.30 | ||
| Power supply | V/Ph/Hz | 230/1/50 | 380/3/50 | 380/3/50 | |||
| Refrigerant | R410A | ||||||
| Compressor Brand | Daikin | Daikin | SANYO | Daikin | SANYO | ||
| Compressor Type | Scroll | Scroll | Scroll | Scroll | Scroll | ||
| Air conditioning tank volume | L | 17 | 20 | 25 | 30 | 30 | |
| Dimensiones | LXHXD | mm | 1090X900X450 | 1090X1000X450 | 1090X1260X450 | 1090X1460X450 | 1090X1460X450 |
| Weight | Kg | 110 | 125 | 165 | 190 | 205 | |
| Noise | dB(A) | 48 | 51 | 50 | 53 | 53 | |
| Loading QTY 20'SQ/40'HQ | PCS | 36/82 | 36/82 | 18/41 | 18/41 | 18/41 | |
| Floor Heating: 7ºC Outdoor air / 35ºC Leaving water. | Heating (Fan Coil): 7ºC Outdoor air / 45ºC Leaving water. | ||||||
| Floor cooling: 35ºC Outdoor air / 16ºC Leaving water.. | Cooling (Fan Coil): 35ºC Outdoor air / 7ºC Leaving water.. | ||||||
| Domestic Hot Water: 7ºC Outdoor air / 40ºC Water in the tank. | |||||||














Send Online Inquiry