China Europe Joint Venture Manufacturer-Original European Technology

Heat pump-central air conditioner

combined heating cooling and hot water heatpump

Heating Cooling Heat Pump Which can be used for room heating and cooling like central air conditioner.

1. Heat pump with combined Heating, cooling air conditoner and domestic hot water function in one solution for all family requirement in whole year.

2. Built inside fuzzy logic solar combination operation utilize solar for both room heating and domestic hot water, which enable more energy saving than other heat pump.

3. Intelligent automatic operation mode of DHW and room heating for more energy saving during different ambient temp;

4. Intelligent auto defrost, antifreeze protection for low ambient temp operation to minus -15.

5. Real weekly timer-Different setting for every day of the week to fit your life habit the most and save energy. Imaging you will enjoy your weekend in tourism with your sweet family, then the heat pump doesn't need to start at weekend.

6. More energy saving and much more comfortable than normal air conditioner;

7.All error code can be checked through controller display which enable you to solve the problem as soon as possible.

Model No Test Condition
Air temp/Oulet water temp
AH-3.5D AH-4.5H AH-7H AH-12H AH-14H AH-17H AH-21H AH-30H
Heating Capcity/Input Power (KW/KW) At A20/W55ºC 3.5/0.8 4.5/1.02 7.05/1.6 12/2.5 14/3.1 17/3.9 21/4.9 30/6.6
At  A7/W35ºC 2.5/0.6 3.8/0.98 5.7/1.5 9/2.14 10.85/2.3 15/3.53 17/4.1 23/5.3
At  A2/W35ºC 1.8/0.58 3.2/0.95 4.89/1.45 7.6/2 8.9/2.27 12.5/3.28 15.1/3.95 20.4/5.2
Cooling Capcity(KW) At  A35/W18ºC 2.6/0.72 4.1/1.15 6.1/1.76 9.1 11.5 15.6 19 24
Power Supply 220V/50HZ 220V or 380V/50HZ 380V/50HZ
Working Range ºC -15 ~ 43
Max Output water temp ºC 60
Mini water flow(L/H)
(Heating- cooling)
M3/hour >=0.35 >=0.6 >=0.8 >=1.2 >=1.8 >=2.4 >=3 >=3.5
Water connection joint mm DN20(3/4'') DN25 DN32
Packing size mm 360*650*790 430*695 *1010 430*695 *1010 415*980 *985 465*1085 *1085 530*1180 *1170 530*1180 *1430 530*1180 *1630
Unit size mm 254*540*772 290*605*850 290*605 *850 325*860 *870 345*960 *970 462*1090 *1016 462*1090 *1272 462*1090 *1475
Protection class IPx4
Anti Shock class Class 1
Refrigerant R410a
Noise dB 40 42 45 48 55 56 57 58
Regulation component Emersion Expansion valve
Compressor type Rotary Scroll
Heating Cooling heat exchanger Stainless Steel Plate Heat exchanger
Loading quantity for 20'/40' pcs 138/276 90/180 90/180 64/128 54/108 42/84 21/42 21/42

Warranty

We provide 1% free spareparts and 1 year warranty for factory fault since shipment arrival.

We will send the spare parts by courrier method after confirm it is due to factory fault.

We don't cover the cost for failure from shipment, wrong installation and incorrect usage. Of course we can provide parts by customer's cost after warranty period.

Customer Service

We can provide free heat pump installation consultation.

We can provide after sales service, technical assistant.
We can help to purchase other parts related to heat pumps or recommand reliable suppliers directly.

Shipping

For heat pump samples delivery, after packing with export class thick 5 layers paper box, we will pack heat pumps with poly wood case to avoid any damage as shown attached.

There are two ways to delivery the samples.

For sea freight, we will keep the refrigerant inside of the heat pump.

For air freight cargo, due to the air line regulation, we need to drain out the refrigerant. So you need to charge the refrigerant if you find the heat pump cannot start.
For all products above 50kg, we will fix it on a good structured wood or polywood pallet as shown below.

For Container delivery, we use only export thick 5 layer paper box. After carefully loading, we will take pictures before close the container door to assure everything is ok.

If by sea, normally we export at EXW, FOB or CFR terms, we only delivery goods to the destination sea port. The customers need to cover cost for their import duty and cost. Of course the customers can use our forwarder agent to help you to clear the customs.
We can provide all necessary document such as Form A, certificate of origin, Bill of lading, Invoice and packing list.

Normally it will take about 30 days by sea and one week by air.

Triaqua Monobloc heat pump-one inner water tank with expansion tank

combined heating cooling and hot water heatpump

1.Triaqua Monobloc heat pump-one inner water tank with expansion tank for easy installation.

2.Heating Cooling and domestic hot water multifunctional  Heat Pump available for 11KW,14KW,17KW,20KW,23KW

3. Intelligent automatic operation mode of DHW and room heating for more energy saving during different ambient temp;

4. Intelligent auto defrost, antifreezeprotection for low ambient temp operation to minus -15.

5. Real weekly timer-Different setting for every dayof the week to fit your life habit the most and save energy. Imaging you will enjoy your weekend in tourism with your sweet family, then the heat pump doesn't need to start at weekend.

6.All error code can be checked through controller display which enable you to solve the problem as soon as possible.

Technical data HLR-110D HLR-140D HLR-170D HLR-200D HLR-230D
Floor heating Capacity KW 11.1 14.52 18.00 21.00 23.90
Power Input KW 2.64 3.30 4.21 4.81 5.41
COP 4.2 4.40 4.28 4.37 4.42
Floor cooling Capacity KW 12.1 15.00 17.50 20.00 23.00
Power Input KW 3.1 3.94 4.56 5.17 5.88
EER 3.9 3.81 3.84 3.87 3.91
Domestic hot water Capacity KW 11 14.08 16.50 19.20 21.80
Power Input KW 2.89 3.75 4.33 5.07 5.74
COP 3.8 3.75 3.81 3.79 3.80
Power supply V/Ph/Hz 230/1/50 380/3/50
Refrigerant R410
 
Compressor Type Scroll Scroll Scroll Scroll Scroll
Air conditioning tank volume L 20 20 25 30 30
Dimensiones LXHXD mm 1090X1000X450 1090X1260X450 1090X1460X450
Weight Kg 110 125 165 190 205
Noise dB(A) 48 51 50 53 53
Loading QTY 20'SQ/40'HQ PCS 36/82 36/82 18/41 18/41 18/41

TEST UNDER European heat pump standard EN14511 STANDARD CONDITION:

Floor Heating: 7°C Outdoor  air / 35°C Leaving water.
Floor cooling: 35°C Outdoor air / 18°C Leaving water..
Domestic Hot Water: 7°C Outdoor air / 40°C Water in the tank.

combined-heating-cooling-and-hot-water-heat-pump-17kw

combined heating cooling and hot water air water heatpump

Heating Cooling Heat Pump available for 2KW,3.5KW,4.5KW,7KW,9KW,11KW,14KW,17KW,20KW,22KW,30,40KW

1. Heat pump with combined Heating, cooling and domestic hot waterfunction in one solution for all family requirement in whole year.

2. Built inside fuzzy logic solar combination operation utilize solar for both room heating and domestic hot water, which enable more energy saving than other heat pump.

3. Intelligent automatic operation modeof DHW and room heating for more energy saving during different ambient temp;

4. Intelligent auto defrost, antifreezeprotection for low ambient temp operation to minus -15.

5. Real weekly timer-Different setting for every dayof the week to fit your life habit the most and save energy. Imaging you will enjoy your weekend in tourism with your sweet family, then the heat pump doesn't need to start at weekend.

6. More energy saving and much more comfortable than normal air conditioner;

7.All error code can be checked through controller display which enable you to solve the problem as soon as possible.

Model No Test Condition
Air temp/Oulet water temp
AH-3.5H AH-4.5H AH-7H AH-12H AH-14H AH-17H AH-21H AH-30H
Heating Capcity/Input Power (KW/KW) At A20/55ºC 3.5/0.8 4.5/1.02 7.05/1.6 12/2.5 14/3.1 17/3.9 21/4.9 30/6.6
At  A7/35ºC 2.5/0.6 3.8/0.98 5.7/1.5 9/2.14 10.85/2.3 15/3.53 17/4.1 23/5.3
At  A2/35ºC 1.8/0.58 3.2/0.95 4.89/1.45 7.6/2 8.9/2.27 12.5/3.28 15.1/3.95 20.4/5.2
Cooling Capcity(KW) At  A35/18ºC 2.6/0.72 4.1/1.15 6.1/1.76 9.1 11.5 15.6 19 24
Power Supply 220V/50HZ 220V or 380V/50HZ 380V/50HZ
Working Range ºC -15 ~ 43
Max Output water temp ºC 60
Mini water flow(L/H)
(Heating- cooling)
M3/hour >=0.35 >=0.6 >=0.8 >=1.2 >=1.8 >=2.4 >=3 >=3.5
Water connection joint mm DN20(3/4'') DN25 DN32
Packing size mm 360*650*790 430*695 *1010 430*695 *1010 415*980 *985 465*1085 *1085 530*1180 *1170 530*1180 *1430 530*1180 *1630
Unit size mm 254*540*772 290*605*850 290*605 *850 325*860 *870 345*960 *970 462*1090 *1016 462*1090 *1272 462*1090 *1475
Protection class IPx4
Anti Shock class Class 1
Refrigerant R410a
Noise dB 40 42 45 48 55 56 57 58
Regulation component Emersion Expansion valve
Compressor type Rotary Scroll
Heating Cooling heat exchanger Stainless Steel Plate Heat exchanger
Loading quantity for 20'/40' pcs 138/276 90/180 90/180 64/128 54/108 42/84 21/42 21/42

Two Years Warranty !

We provide 1% free spareparts with containered order and 2 year warranty of main parts for factory fault since shipment arrival.

We will send the spare parts by courrier method after confirm it is due to factory fault.

We don't cover the cost for failure from shipment, wrong installation and incorrect usage. Of course we can provide parts by customer's cost after warranty period.

Customer Service

We can provide free heat pump installation consultation.

We can provide after sales service, technical assistant.

We can help to purchase other parts related to heat pumps or recommand reliable suppliers directly.

Shipping

For heat pump samples delivery, after packing with export class thick 5 layers paper box, we will pack heat pumps with poly wood case to avoid any damage as shown attached.

There are two ways to delivery the samples.

For sea freight, we will keep the refrigerant inside of the heat pump.

For air freight cargo, due to the air line regulation, we need to drain out the refrigerant. So you need to charge the refrigerant if you find the heat pump cannot start.

For all products above 50kg, we will fix it on a good structured wood or polywood pallet as shown below.

For Container delivery, we use only export thick 5 layer paper box. After carefully loading, we will take pictures before close the container door to assure everything is ok.

If by sea, normally we export at EXW, FOB or CFR terms, we only delivery goods to the destination sea port. The customers need to cover cost for their import duty and cost. Of course the customers can use our forwarder agent to help you to clear the customs.

We can provide all necessary document such as Form A, certificate of origin, Bill of lading, Invoice and packing list.

Normally it will take about 30 days by sea and one week by air.

Combined heating cooling and hot water heat pump 2kw-30kw

combined heating cooling and hot water heatpump

Heating Cooling Heat Pump available for 2KW,3.5KW,4.5KW,7KW,9KW,11KW,15KW,17KW,20KW,22KW,30,40KW

1. Heat pump with combined Heating, cooling and domestic hot water function in one solution for all family requirement in whole year.

2. Built inside fuzzy logic solar combination operation utilize solar for both room heating and domestic hot water, which enable more energy saving than other heat pump.

3. Intelligent automatic operation mode of DHW and room heating for more energy saving during different ambient temp;

4. Intelligent auto defrost, antifreeze protection for low ambient temp operation to minus -15.

5. Real weekly timer-Different setting for every day of the week to fit your life habit the most and save energy. Imaging you will enjoy your weekend in tourism with your sweet family, then the heat pump doesn't need to start at weekend.

6. More energy saving and much more comfortable than normal air conditioner;

7.All error code can be checked through controller display which enable you to solve the problem as soon as possible.

Two Years Warranty !

We provide 1% free spareparts with containered order and 2 year warranty of main parts for factory fault since shipment arrival.

We will send the spare parts by courrier method after confirm it is due to factory fault.

We don't cover the cost for failure from shipment, wrong installation and incorrect usage. Of course we can provide parts by customer's cost after warranty period.

Customer Service

We can provide free heat pump installation consultation.

We can provide after sales service, technical assistant.

We can help to purchase other parts related to heat pumps or recommand reliable suppliers directly.

Shipping

For heat pump samples delivery, after packing with export class thick 5 layers paper box, we will pack heat pumps with poly wood case to avoid any damage as shown attached.

There are two ways to delivery the samples.

For sea freight, we will keep the refrigerant inside of the heat pump.

For air freight cargo, due to the air line regulation, we need to drain out the refrigerant. So you need to charge the refrigerant if you find the heat pump cannot start.

For all products above 50kg, we will fix it on a good structured wood or polywood pallet as shown below.

For Container delivery, we use only export thick 5 layer paper box. After carefully loading, we will take pictures before close the container door to assure everything is ok.

If by sea, normally we export at EXW, FOB or CFR terms, we only delivery goods to the destination sea port. The customers need to cover cost for their import duty and cost. Of course the customers can use our forwarder agent to help you to clear the customs.

We can provide all necessary document such as Form A, certificate of origin, Bill of lading, Invoice and packing list.

Normally it will take about 30 days by sea and one week by air.

Heat recovery heat pump 7kw-9kw

Heat recovery heat pump
Thanks to our Epoch-Making new technolgy, Our new heat recovery heat pump efficency (COP) is more than 7.0 when central cooling + hot water; COP is up to 5.0 when central heating+hot water.

It means 1KW electricity input equal 7KW output.

heat-recovery-heat-pump-working-theory
 

 

 

 

 

 

 

 

 

 

 

 

 

Central Heating+Central Cooling+Domestic hot water with heat recovery Heat Pump available for 7KW,10KW,14KW,17KW,20KW,25KW,30KW,40KW,50KW,60KW

Product Function:

Central Heating, central cooling and domestic hot water function in one solution.

Provide free hot water when cooling

Provide efficient hot water when heating.
Product Characters:
1. Energy-saving 50-60% compared with traditional air-conditioner;
2. In summer produce free hot water when cooling; In winter hot water and central heating are synchronously produced with high efficency upto 5.0 ;
3. Suitable for -15c~+45 C ambient temperature;
4. Environment friendly: R410a refrigerant, no pollution, no waste discharge;
5. Economic: The running cost of palm heat pump can be 85% less than that of a traditional gas boiler heating system;

6.Advanced timer setting function for heat pump:
Single day timer and Weekly timer are both available.Can be different setting for every day of the whole week.

7.Phone remote control function for heat pump is optional
Control the operation and check the operation mode through simple phone call.

8. Historical record for all heat pump operation for long years.

Heat recovery heat pump technical data:

 

 

Model 7K 10K 14K 17K 20K 25K 30K 40K 50K 60K
Cooling Capcity(KW) 5.8 8.5 11.5 13.5 15 20 24 32 41 50
Heating Capcity(KW) 7 10 14 17 20 25 30 40 50 60
Input power(KW) 2 2.8 4.3 4.8 5.2 6.5 7.9 10.5 13.2 15.8
Cooling+DHW COP 7
Power Supply 220V/50HZ 380V/50
Max Output water temp 60ºC
Mini water flow(L/H)(DHW) 1200 1800 2400 3000 3500 4300 5200 6800 8600 10000
Mini water flow(L/H)(Heating and cooling) 1200 1800 2400 3000 3500 4300 5200 6800 8600 10000
Water connection joint(mm) DN25 DN32 DN50
Packing size(mm) 415*980*985 465*1085*1085 530*1180*1170 530*1180*1430 530*1180*1630 1070*1680*1990
Unit size(mm) 325*860*870 345*960*970 462*1090*1016 462*1090*1271 462*1090*1473 970*1580*1890
Protection class IPx4
Anti Shock class Class 1
Refrigerant R410a
Regulation component Emersion Expansion valve
Compressor type Rotary Scroll Scroll(Dual compressor)
DHW heat exchanger Pipe in Pipe Heat exchanger Copper pipe+ aluminum fins Copper pipe+ aluminum fins
Heating Cooling heat exchanger Pipe in Pipe Heat exchanger Plate heat exchanger Plate heat exchanger or pipe shell heat exchanger

DC inverter air source heat pump 11KW-product-180

 

Heating and Cooling DC Inverter air source Heat Pump with R410a ,  6KW,8KW,10KW 

Higer efficiency than normal air source heat pump.  

  

Main Characters: 

1.  Heating and Cooling function 
2.  
Extrimly energy saving, super cost saving with R410a gas inside.
3.  Installation is easy and flexible.
.
4.  Can be connected with solar water heater system.
5.  All water access parts are stainless steel to keep safe, healthy and non-pollution 

 Quality for reliability and save maintenance cost:
  Our parts are always choosend with the top brand in the world 
  Heat exchanger: SWEP brand plate heat exchanger from Sweden.
  Heat expansion valve: Emerson brand
  Four way valve: Saginomiya brand of Japan
The above parts enable our heat pump to be trouble free products.

Heat-Recovery-Heat-Pump-for-Heat-Cool-Hot-Water-product-178


 

Thanks to our Epoch-Making new technolgy, our new heat recovery heat pump efficency (COP) is up to 7.0 when central cooling + hot water; COP is up to 5.0 when central heating+hot water.

It means 1KW electricity input  equal 7KW output.

heat-recovery-heat-pump-working-theory

 

Palm Central Heating+Central Cooling+Domestic hot water with heat recovery Heat Pump available for 7KW,10KW,14KW,17KW,20KW,25KW,30KW,40KW,50KW,60KW

Product Function:

Central Heating, central cooling and domestic hot water function in one solution.

Provide free hot water when cooling 

Provide efficient hot water when heating.
Product Characters: 
1. Energy-saving 50-60% compared with traditional air-conditioner;
2. In summer produce free hot water when cooling; In winter hot water and central heating are synchronously produced with high efficency upto 5.0 ;
3. Suitable for -15c~+45 C ambient temperature;

4. Environment friendly: R410a refrigerant, no pollution, no waste discharge;

5. Economic: The running cost of palm heat pump can be 85% less than that of a traditional gas boiler heating system;

6.Advanced timer setting function for heat pump :
Single day timer and Weekly timer are both available.Can be different setting for every day of the whole week.

Heat recovery heat pump technical data:

Model AH-7R-410 AH-9R-410 AH-15R-410 AH-17R-410 AH-20R 25K 30K 40K 50K 60K
Cooling Capcity(KW) 7.8 9.5 14.5 17.5 21 26 31 40 51 60
Heating Capcity(KW) 7 9 14 17 20 25 30 40 50 60
Input power(KW) 2 2.3 4.3 4.8 5.2 6.5 7.9 10.5 13.2 15.8
Cooling+DHW COP 7
Power Supply 220V/50HZ 380V/50
Max Output water temp 60ºC
Mini water flow(L/H)(DHW) 1200 1800 2400 3000 3500 4300 5200 6800 8600 10000
Mini water flow(L/H)(Heating and cooling) 1200 1800 2400 3000 3500 4300 5200 6800 8600 10000
Water connection joint(mm) DN25 DN32 DN50
Packing size(mm) 415*980*985 465*1085*1085 530*1180*1170 530*1180*1430 530*1180*1630 1070*1680*1990
Unit size(mm) 325*860*870 345*960*970 462*1090*1016 462*1090*1271 462*1090*1473 970*1580*1890
Protection class IPx4
Anti Shock class Class 1
Refrigerant R410a
Regulation component Emersion Expansion valve
Compressor type Rotary Scroll Scroll(Dual compressor)
DHW heat exchanger Copper pipe+ aluminum fins Copper pipe+ aluminum fins Copper pipe+ aluminum fins
Heating Cooling heat exchanger Plate heat exchanger Plate heat exchanger Plate heat exchanger or pipe shell heat exchanger
 

 

Reliable Quality for saving maintenance cost:
  Our parts are always choosend with the top brand in the world
Heat exchanger: SU316 stainless plate heat exchanger.
The compressor: Daikin, Hitachi,Toshiba,Sanyo brand
Heat expansion valve: Emerson brand
Optional water pump: Wilo brand from Germany
Four way valve: Saginomiya brand of Japan
The above parts enable our heat pump to be trouble free products.

Warranty

We provide 1% free spareparts and 1 year warranty for factory fault since shipment arrival.
We will send the spare parts by courrier method after confirm it is due to factory fault.
We don't cover the cost for failure from shipment, wrong installation and incorrect usage. Of course we can provide parts by customer's cost after warranty period.

Customer Service

We can provide free heat pump installation consultation.
We can help to purchase other parts related to heat pumps or recommand reliable suppliers directly.

Shipping

For heat pump samples delivery, after packing with export class thick 5 layers paper box, we will pack heat pumps with poly wood case to avoid any damage as shown attached.

There are two ways to delivery the samples.
For sea freight, we will keep the refrigerant inside of the heat pump.
For air freight cargo, due to the air line regulation, we need to drain out the refrigerant. So you need to charge the refrigerant if you find the heat pump cannot start.
For all products above 50kg, we will fix it on a good structured wood or polywood pallet as shown below.
 

For Container delivery, we use only export thick 5 layer paper box. After carefully loading, we will take pictures before close the container door to assure everything is ok.

If by sea, normally we export at EXW, FOB or CFR terms, we only delivery goods to the destination sea port. The customers need to cover cost for their import duty and cost. Of course the customers can use our forwarder agent to help you to clear the customs.
We can provide all necessary document such as Form A, certificate of origin, Bill of lading, Invoice and packing list.

Normally it will take about 30 days by sea and one week by air.

Air to water heat pump 3.5KW 4KW 6kw to 68KW-product-157

Air to Water Heat Pumps Specification
Models (1)
AH-35H/N1
COP
AH-35H/N1a
COP
AH(P)-55H/N1
COP
AH(P)-80H/N1
COP
AH-110H/SN1
COP
Heating capacity(2) /Power input (KW)
at A20/W35ºC (3)
4.6/1.09
4.22
4.6/1.15
4
7.04/1.68
4.19
10.62/2.43
4.37
14.41/3.38
4.26
at A20/W50ºC (3)
4.5/1.4
3.2
4.5/1.4
3.21
6.8/2.15
3.16
10.25/3.12
3.29
14.0/4.29
3.26
at A15/W50ºC (3)
4.1/1.35
3.0
4.1/1.35
3.04
6.25/2.07
3.02
9.34/3.0
3.11
12.76/4.13
3.09
at A7/W35ºC (3)
3.6/0.98
3.7
3.6/0.98
3.67
5.5/1.5
3.67
8.2/2.18
3.76
11.2/3.0
3.73
at A7/W45ºC (3)
3.58/1.15
3.1
3.58/1.15
3.11
5.47/1.76
3.11
8.15/2.56
3.18
11.14/3.52
3.16
at A7/W50ºC (3)
3.4/1.26
2.7
3.4/1.26
2.7
5.24/1.92
2.73
7.8/2.76
2.83
10.8/3.8
2.84
at A2/W35ºC (3)
3.2/0.95
3.4
3.2/0.95
3.37
4.89/1.45
3.37
7.29/2.11
3.45
9.96/2.91
3.42
at A2/W50ºC (3)
3.05/1.23
2.5
3.05/1.23
2.48
4.66/1.88
2.48
6.95/2.74
2.54
9.49/3.77
2.52
at A0/W45ºC (3)
2.85/1.12
2.5
2.85/1.12
2.54
4.35/1.71
2.54
6.49/2.49
2.61
8.87/3.43
2.59
at A-7/W45ºC (3)
2.2/1.1
2.0
2.2/1.1
2
3.36/1.68
2
5.01/2.45
2.04
6.84/3.37
2.03
at A-7/W50ºC (3)
2.15/1.18
1.8
2.15/1.18
1.82
3.28/1.81
1.81
4.9/2.62
1.87
6.69/3.61
1.85
colling capacity/Power input(KW)
at A35/W7ºC (3)
3.3/1.15
2.9
3.3/1.15
2.9
5.1/1.76
2.9
7.6/2.56
2.97
10.5/3.52
2.98
Max.power input (KW)
1.8
1.8
2.6
3.8
5.5
Max.currentt (A)
8.2
8.2
12.5
17.4
9
Electric supply
230V-50Hz
400V-3N-50Hz
Max.water temperature (ºC)
60
Running temperature range (ºC)
-15~43
Refrigerant circuit
Refrigerant
R407C
compressor(s)
Rotary
Rotary
Rotary
Rotary
Scroll
Heat exchange
High efficiency fin-tube heat exchanger
Fan motor (W)
35
80
80
150
250
Air flow (m3/h)
2000
3000
3000
4500
6500
Water circuit
Heat exchanger
Stainless steel plate heat exchanger
In/Out pipe
DN20(3/4'')
DN20(3/4'')
DN20(3/4'')
DN25(1'')
DN25(1'')
Water flow (m3/h)
>=0.6
>=0.6
>=0.8
>=1.2
>=1.6
permitted pressure
=<0.8MPa
Unit dimensions WxHxD (mm)
772x540x254
850x605x290
850x605x290
850x850x310
970x960x360
Pacage dimensions WxHxD (mm)
790x650x360
1010x695x430
1010x695x430
1010x875x430
1100x1100x440
Net weight (Kg)
45
52
65
81
110
Gross weight (Kg)
47
57
68
86
118
Noise level (dB(A))
51
51
52
54
56
Electric heater(optional) (4) (KW)

Air to Water Heat Pumps Specification
Models (1)
AH(P)-160H/SN1
COP
AH(P)-220H/SN1
COP
AH(DP)-280H/SN1
COP
AH(DP)-560H/SN1
COP
AH(DP)-680H/SN1
Heating capacity(2) /Power input (KW)
at A20/W35ºC (3)
21.51/5.12
4.2
28.7/6.9
4.16
36.5/9.1
4.01
71.68/17.72
4.05
86.95/21.99
at A20/W50ºC (3)
20.8/6.5
3.2
28.0/8.58
3.26
35.4/11.15
3.19
70/21.66
3.24
85/26.88
at A15/W50ºC (3)
18.79/6.34
2.96
25.6/8.25
3.1
32.2/10.7
3.01
63.78/20.87
3.07
77.44/25.9
at A7/W35ºC (3)
16.5/4.6
3.59
22.4/6.0
3.73
28.3/7.8
3.63
56/15.15
3.71
68/18.8
at A7/W45ºC (3)
16.41/5.4
3.04
22.28/7.04
3.16
28.14/9.15
3.08
55.69/17.78
3.15
67.62/22.06
at A7/W50ºC (3)
15.7/5.9
2.66
21.3/7.7
2.77
27.2/10
2.72
52.89/19.48
2.73
64.22/24.17
at A2/W35ºC (3)
14.67/4.46
3.29
19.91/5.82
3.42
25.16/7.56
3.33
49.78/14.69
3.41
60.44/18.22
at A2/W50ºC (3)
13.98/5.77
2.42
18.98/7.53
2.52
23.98/9.79
2.45
47.44/19.01
2.5
57.61/23.6
at A0/W45ºC (3)
13.06/5.26
2.48
17.73/6.86
2.58
22.4/8.91
2.51
44.33/17.31
2.56
53.83/21.49
at A-7/W45ºC (3)
10.08/5.16
1.95
13.69/6.73
2.03
17.29/8.76
1.97
34.22/17.01
2.01
41.56/21.10
at A-7/W50ºC (3)
9.85/5.54
1.78
13.38/7.22
1.85
16.9/9.39
1.8
33.44/18.24
1.84
40.61/22.64
colling capacity/Power input(KW)
at A35/W7ºC (3)
15/5.4
2.78
20/7.04
2.84
26.3/9.15
2.87
52.5/17.1878
3.07
66/22.06
Max.power input (KW)
8
10.4
13.5
26.3
32.7
Max.currentt (A)
13
17
22
42.8
53.1
Electric supply
400V-3N-50Hz
Max.water temperature (ºC)
60
Running temperature range (ºC)
-15~43
Refrigerant circuit
Refrigerant
R407C
compressor(s)
Scroll
Scroll
2xScroll
4xScroll
4xScroll
Heat exchange
High efficiency fin-tube heat exchanger
Fan motor (W)
150x2
250x2
700
700x2
850x2
Air flow (m3/h)
9000
12000
14500
28000
32000
Water circuit
Heat exchanger
Stainless steel plate heat exchanger
Double pipe heat exchangr
In/Out pipe
DN32(1-1/4")
DN32(1-1/4")
DN40(1-1/2")
DN50(2")
DN50(2")
Water flow (m3/h)
>=2.2
>=3.0
>=3.5
>=7.0
>=9.0
permitted pressure
=<0.8MPa
Unit dimensions WxHxD (mm)
970x1258x380
970x1500x360
1265x1760x1020
1950x1930x1100
Pacage dimensions WxHxD (mm)
1070x1410x450
1100x1640x440
1415x1890x1200
2200x2200x1350
Net weight (Kg)
140
180
300
560
620
Gross weight (Kg)
150
195
325
600
660
Noise level (dB(A))
56
57
59
61
62
Electric heater(optional) (4) (KW)
9
20
5

Note:
(1) The circulation pump and the auxiliary electric heater is optional.D:with inside auxiliary electric heater; P:with inside circulation.
(2)The data of stable running condition(when defrosting,the average heating capacity reduces about 10% compare to corresponding data)
(3)Surrounding air temperature/outlet water temperature
(4)The electric heater must be equipped outside for the models fom AH-35H/N1 to AH(P)-220H/SN1.AHP-280 and AHP-350 electric heater can be installed inside of the unit.

Product Description

Our heat pump is a new generation heat pump prduct developed with the most advanced heating technologies. The heat pump utilizeds the energy from surrounding air and converts it to the hot water for house air conditioning heating cooling and domestic hot water supply. The whole range of this heat pump is strictly tested with our European partners to make sure the best quality for European market. Especially for super low temperature area. The working abient is -15 degree to 45 degree and keep supply of warm water from 35 degree to 60 degree.

We select the best well known components for our heat pump such as Copeland compressor, Siemens, Danfoss, Wilo. It provide the most reliability to our customers.
Striking characters distinguish from other products

1.High efficiency and energy saving

2.Environmental friendly refrigerant

3.Keep working in super low temperature

4.Using step fan motor to make the accurate control

5.Water flow protection, pressure prtection, temp protection keep the the system safety.
Other characters

1.Stainless steel plate heat exchanger with maximum pressure 40 bar

2.100% stainless water circuit to keep water clean

3.Microprocessor control and error alarm and display

4.Electric protection class IPX4

5.Compact design for good looking, easy installation and maintenance

Heating Cooling Hot Water MonoBloc HeatPump 14KW-product-176


Heating Cooling heat pump available for 11KW,14KW,17KW,20KW,23KW
A.Heat pump with Heating, cooling and domestic hot water function in one solution.
B. One water tank built inside
C. More Operation Mode for heat pump:
DHW automatic operation mode for more energy saving;
Air heating automatic operation mode to achieve more energy saving;
Great economical air heating mode to keep comfortable feeling with most energy saving;

D.More advanced timer setting function for heat pump:
1.Single day timer
Three periods on and off setting (Avoid electric peak time to use the cheapest electric and save your bill the most)
2.Weekly timer
Different setting for every day of the week. Totally 42 timer period available for setting

E.Great phone remote control function for heat pump
Control the operation and check the operation mode through simple phone call.

F.Protection function and Error code display for heat pump
1.Pressure, miss phase, wrong phase and high temp protection, water flow protection, antifreeze protection.
2.All error can be checked through controller and error LED light.
G. Historical memory for all heat pump operation for long years. 

 

 
Mini Chiller SPECIFICATION
Technical data HLR-110D HLR-140D HLR-170D HLR-200D HLR-230D
Floor heating Capacity KW                   11.50                   14.30                   18.00                   21.00                   23.90
Power Input KW                     2.70                     3.70                     4.20                     4.80                     5.40
COP                       4.26                     3.82                     4.28                     4.37                     4.42
Fan coil heating Capacity KW                   10.30                   13.50                   16.60                   19.50                   22.80
Power Input KW                     3.00                     3.80                     4.70                     5.70                     6.80
COP                       3.43                     3.55                     3.53                     3.42                     3.35
Floor cooling Capacity KW                   11.00                   15.00                   17.50                   20.00                   23.00
Power Input KW                     3.10                     4.40                     4.80                     5.30                     6.10
EER                       3.55                     3.41                     3.64                     3.77                     3.77
Fan coil cooling Capacity KW                     8.80                   12.30                   15.50                   17.50                   20.80
Power Input KW                     2.90                     4.00                     4.90                     5.50                     7.10
EER                       3.03                     3.07                     3.16                     3.18                     2.93
Domestic hot water Capacity KW                   10.40                   13.50                   16.50                   19.20                   21.80
Power Input KW                     2.80                     3.80                     4.80                     5.60                     6.60
COP                       3.71                     3.55                     3.44                     3.43                     3.30
Power supply   V/Ph/Hz 230/1/50 380/3/50 380/3/50
Refrigerant     R410A
Compressor Brand     Daikin  Daikin  SANYO  Daikin  SANYO 
Compressor Type     Scroll Scroll  Scroll Scroll  Scroll
Air conditioning tank volume   L 17 20 25 30 30
Dimensiones LXHXD mm 1090X900X450 1090X1000X450 1090X1260X450 1090X1460X450 1090X1460X450
Weight   Kg 110 125 165 190 205
Noise   dB(A) 48 51 50 53 53
Loading QTY  20'SQ/40'HQ PCS 36/82 36/82 18/41 18/41 18/41
               
Floor Heating: 7ºC Outdoor  air / 35ºC Leaving water.  Heating (Fan Coil): 7ºC Outdoor air / 45ºC Leaving water. 
Floor cooling: 35ºC Outdoor air / 16ºC Leaving water..  Cooling (Fan Coil): 35ºC Outdoor  air / 7ºC Leaving water.. 
Domestic Hot Water: 7ºC Outdoor air / 40ºC Water in the tank.   

Heat Pump Mini Chiller Heating-Cooling-DHW-17-23KW-product-158

   


Heating Cooling Heat Pump available for 11KW,14KW,17KW,20KW,23KW
DHW automatic operation mode for more energy saving;
Air heating automatic operation mode to achieve more energy saving;
Great economical air heating mode to keep comfortable feeling with most energy saving;

A.Heat pump with Heating, cooling and domestic hot water function in one solution.
B. One water tank built inside
C. More Operation Mode for heat pump:

D.More advanced timer setting function for heat pump:
1.Single day timer
Three periods on and off setting (Avoid electric peak time to use the cheapest electric and save your bill the most)
2.Weekly timer
Different setting for every day of the week. Totally 42 timer period available for setting

E.Great phone remote control function for heat pump
Control the operation and check the operation mode through simple phone call.

F.Protection function and Error code display for heat pump
1.Pressure, miss phase, wrong phase and high temp protection, water flow protection, antifreeze protection.
2.All error can be checked through controller and error LED light.
G. Historical memory for all heat pump operation for long years.

Mini Chiller SPECIFICATION
Technical data HLR-110D HLR-140D HLR-170D HLR-200D HLR-230D
Floor heating Capacity KW                   11.50                   14.30                   18.00                   21.00                   23.90
Power Input KW                     2.70                     3.70                     4.20                     4.80                     5.40
COP                       4.26                     3.82                     4.28                     4.37                     4.42
Fan coil heating Capacity KW                   10.30                   13.50                   16.60                   19.50                   22.80
Power Input KW                     3.00                     3.80                     4.70                     5.70                     6.80
COP                       3.43                     3.55                     3.53                     3.42                     3.35
Floor cooling Capacity KW                   11.00                   15.00                   17.50                   20.00                   23.00
Power Input KW                     3.10                     4.40                     4.80                     5.30                     6.10
EER                       3.55                     3.41                     3.64                     3.77                     3.77
Fan coil cooling Capacity KW                     8.80                   12.30                   15.50                   17.50                   20.80
Power Input KW                     2.90                     4.00                     4.90                     5.50                     7.10
EER                       3.03                     3.07                     3.16                     3.18                     2.93
Domestic hot water Capacity KW                   10.40                   13.50                   16.50                   19.20                   21.80
Power Input KW                     2.80                     3.80                     4.80                     5.60                     6.60
COP                       3.71                     3.55                     3.44                     3.43                     3.30
Power supply   V/Ph/Hz 230/1/50 380/3/50 380/3/50
Refrigerant     R410A
Compressor Brand     Daikin  Daikin  SANYO  Daikin  SANYO 
Compressor Type     Scroll Scroll  Scroll Scroll  Scroll
Air conditioning tank volume   L 17 20 25 30 30
Dimensiones LXHXD mm 1090X900X450 1090X1000X450 1090X1260X450 1090X1460X450 1090X1460X450
Weight   Kg 110 125 165 190 205
Noise   dB(A) 48 51 50 53 53
Loading QTY  20'SQ/40'HQ PCS 36/82 36/82 18/41 18/41 18/41
               
Floor Heating: 7ºC Outdoor  air / 35ºC Leaving water.  Heating (Fan Coil): 7ºC Outdoor air / 45ºC Leaving water. 
Floor cooling: 35ºC Outdoor air / 16ºC Leaving water..  Cooling (Fan Coil): 35ºC Outdoor  air / 7ºC Leaving water.. 
Domestic Hot Water: 7ºC Outdoor air / 40ºC Water in the tank.   

Send Online Inquiry

Send Online Inquiry

Key Features of Our Heat Pump

  • Original European Technology of Heat Pump
  • High COP Energy Saving with R410a
  • World Top Brand Parts for Heat Pump Life Duration
  • Safety and no Harmful Material Emission
China Palm A/C & Equipment Co.Ltd
Register No: Joint Venture(Guangdong) No #304091
Joint Venture Certificate assigned by government Authenticated and Verified by ZD info Credit Certificate issued by CHC Credit Evaluation Bureau